Abstract

The objective of this study was to evaluate the effect of 2 different degrees of mandibular advancement, 50% vs. 75% of maximum protrusive capacity, on somnographic variables after 1 year of dental appliance treatment in patients with mild to moderate obstructive sleep apnea (OSA). A further purpose was to compare the number of adverse events on the stomatognathic system. In a prospective study, 74 male patients were randomly allocated to receive a dental appliance with either 50% (38 patients) or 75% mandibular advancement (36 patients). After 1 year of treatment, 55 patients completed the follow-up. Somnography was performed to measure treatment effects before and 12 months post-treatment. The apnea, apnea/hypopnea, and oxygen desaturation indices decreased significantly in both groups after 1 year (P < 0.001); however, there were no differences between the groups. Normalization (apnea index < 5 and apnea/hypopnea index < 10) was observed in 79% in group 50 and in 73% in group 75. Few patients (< 5%) reported symptoms from the stomatognathic system except for headache (> once a week), which was reported in one-third of the patients. Headache was significantly more infrequent after 1 year of treatment in both groups (P < 0.001). No serious complications were observed except for 2 patients who reported a painful condition from the temporomandibular joint in either group. In conclusion, mandibular advancement with a dental appliance effectively reduces the sleep-breathing disorder measured as frequency of apneas, and a pronounced mandibular advancement did not show a greater improvement of the medical problem compared to less advancement for patients with mild to moderate OSA. On the basis of few adverse events in the stomatognathic system or other complications we can recommend dental appliance treatment and, for patients with mild to moderate obstructive sleep apnea, not starting treatment by more than 50% mandibular advancement.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/00016350310007130

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 115

Metadata

Authors
Tegelberg, Å., Walker‐Engström, M., Vestling, O., & Wilhelmsson, B.
Venue
Acta Odontologica Scandinavica
Published
2003-01
Volume
61
Issue
6
Pages
356-362
ISSN
  • 0001-6357 (ISSN-L)
  • 1502-3850
OpenAlex
W2040871868
Cited by
115
References
1
FWCI
0.72
Type
journal article
Language
en
Open access
diamond

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Two different degrees of mandibular advancement with a dental appliance in treatment of patients with mild to moderate obstructive sleep apnea. https://app.cochat.ai/papers/10.1080/00016350310007130
The paper
Tegelberg, Å., Walker‐Engström, M., Vestling, O., & Wilhelmsson, B. (2003). Two different degrees of mandibular advancement with a dental appliance in treatment of patients with mild to moderate obstructive sleep apnea. Acta Odontologica Scandinavica. https://doi.org/10.1080/00016350310007130

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.