The DOI matches its Crossref record; 38 of the 39 references it cites were found in a registry or an index.
Comparison of a Custom-made and a Thermoplastic Oral Appliance for the Treatment of Mild Sleep Apnea
Abstract
Rationale: The efficacy of immediate adaptation of mandibular advancement devices made of thermoplastic material as a treatment option for sleep-disordered breathing (SDB) has been demonstrated in clinical studies. To date, there have been no studies comparing the efficacy of such prefabricated devices with custom-made devices. Objectives: Our purpose was to compare the efficacy of both types of devices in patients with SDB. Methods: A randomized controlled cross-over trial, comprising 4 months of treatment with a thermoplastic and a custom-made device, with a 1-month washout interval. Measurements and Main Results: A total of 35 patients (29 males; age, 49 ± 9 yr; apnea–hypopnea index [AHI], 13 ± 11 events/h; body mass index, 28 ± 4 kg/m2) completed the protocol. AHI was only reduced with the custom-made device (P = 0.005). In addition, this device reduced snoring to a greater extent than the thermoplastic device. The success rate was higher with the custom-made device (60 vs. 31%; P = 0.02). One-third of the patients demonstrated compliance failure with the thermoplastic device, mainly because of insufficient overnight retention. Total failure rate with the thermoplastic device was 69%, whereas the majority (63%) of these were successfully treated with the custom-made device. At the end of the study, 82% of the patients preferred the custom-made device, and 9% had no preference (P < 0.0001). Conclusions: In this study, a custom-made device turned out to be more effective than a thermoplastic device in the treatment of SDB. Our results suggest that the thermoplastic device cannot be recommended as a therapeutic option nor can it be used as a screening tool to find good candidates for mandibular advancement therapy.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Comparison between device designs indicated that there are only minor differences in treatment effects between custom-made devices 78, 80, 83, 84, while a prefabricated device was less effective 85.”
From Non-CPAP therapies in obstructive sleep apnoea (2011) · cites this paper as [85]
Citations
Cites
A New Method for Measuring Daytime Sleepiness: The Epworth Sleepiness Scale
Johns, M. W. (1991) · Sleep · doi:10.1093/sleep/14.6.540 · Cited by 17,364 · cited 1×
“To assess daytime sleepiness, the subjects completed an ESS at each evaluation (33).”
MethodRechtschaffen, A. (1968) · Medical Entomology and Zoology · Cited by 12,638
The Occurrence of Sleep-Disordered Breathing among Middle-Aged Adults
Young, T., Palta, M., Dempsey, J., Skatrud, J., Weber, S., & Badr, S. (1993) · New England Journal of Medicine · doi:10.1056/nejm199304293281704 · Cited by 10,183 · cited 1×
“OSAHS, characterized by repetitive pharyngeal collapse during sleep, can be diagnosed in 4% of middle-aged men and 2% of women (1).”
BackgroundMcNicholas, W. T., Strohl, K. P., White, D. P., Levy, P. A., Schmidt, W., Wheatley, J. R., Redline, S. S., Carley, D. W., Buysse, D. J., Young, T. B., et al. (1999) · PubMed · Cited by 3,665
Sullivan, C., Berthon-Jones, M., Issa, F., & Eves, L. (1981) · The Lancet · doi:10.1016/s0140-6736(81)92140-1 · Cited by 2,731 · cited 7×
“Treatment with MADs may also be considered in subjects with OSAHS who do not tolerate or comply with CPAP or as a temporary alternative (7, 18, 19).”
BackgroundInfluentialEEG Arousals: Scoring Rules and Examples
(1992) · Sleep · doi:10.1093/sleep/15.2.173 · Cited by 1,637
Malhotra, A., & White, D. P. (2002) · The Lancet · doi:10.1016/s0140-6736(02)09464-3 · Cited by 1,190
Cross-Over Trials in Clinical Research
(1994) · Technometrics · doi:10.1080/00401706.1994.10485798 · Cited by 763
Kushida, C. A., Morgenthaler, T. I., Littner, M. R., Alessi, C. A., Bailey, D., Coleman, J., Friedman, L., Hirshkowitz, M., Kapen, S., Kramer, M., et al. (2006) · Sleep · doi:10.1093/sleep/29.2.240 · Cited by 749
Research works printed but not linked: 8
- 1981, Lancet, 1, 862
- 2005, Cochrane Database Syst Rev, CD001004
- 2007, Sleep Breath, 11, 1
- 2006, Cochrane Database Syst Rev, CD004435
- 2004, Lancet, 360, 237
- 2005, Proc Am Thorac Soc, 2, A612
- 2002, Acta Otorhinolaryngol Belg, 56, 195
- 2002, Acta Otorhinolaryngol Belg, 56, 127
Cited by
Upper-Airway Stimulation for Obstructive Sleep Apnea
Strollo, P. J., Soose, R. J., Maurer, J. T., de Vries, N., Cornelius, J., Froymovich, O., Hanson, R. D., Padhya, T. A., Steward, D. L., Gillespie, M. B., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1308659 · Cited by 1,299
Self-citationRamar, K., Dort, L. C., Katz, S. G., Lettieri, C. J., Harrod, C. G., Thomas, S. M., & Chervin, R. D. (2015) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.4858 · Cited by 915
Oral Appliance Treatment for Obstructive Sleep Apnea: An Update
Sutherland, K., Vanderveken, O. M., Tsuda, H., Marklund, M., Gagnadoux, F., Kushida, C. A., Cistulli, P. A., & on behalf of the ORANGE-Registry (Oral Appliance Network on Global Effectiveness) (2014) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.3460 · Cited by 515
“11,101 Although subjective adherence reports suggest short-term adherence is relatively good, 23,60,63,101 exceeding that of CPAP, the discrepancy between subjective and objective CPAP usage 4 suggests that better adherence to OA m cannot be confirmed in the absence of objective moni - toring.”
Self-citationNon-CPAP therapies in obstructive sleep apnoea
Randerath, W. J., Verbraecken, J., Andreas, S., Bettega, G., Boudewyns, A., Hamans, E., Jalbert, F., Paoli, J. R., Sanner, B., Smith, I., et al. (2011) · European Respiratory Journal · doi:10.1183/09031936.00099710 · Cited by 388
Self-citationObstructive sleep apnoea syndrome and its management
Spicuzza, L., Caruso, D., & Di Maria, G. (2015) · Therapeutic Advances in Chronic Disease · doi:10.1177/2040622315590318 · Cited by 328
“Better outcomes and a better compliance have been obtained with custommade devices [Vanderveken et al. 2008].”
Background
Metadata
- Authors
- Vanderveken, O. M., Devolder, A., Marklund, M., Boudewyns, A. N., Braem, M. J., Okkerse, W., Verbraecken, J. A., Franklin, K. A., De Backer, W. A., & Van de Heyning, P. H.
- Affiliations
- University of Antwerp (BE)
- Antwerp University Hospital (BE)
- Umeå University (SE)
- Department of Otorhinolaryngology, Head and Neck Surgery
- Department of Dentistry, University Hospital Antwerp, Edegem, Belgium
- Department of Pulmonary Medicine, University Hospital Antwerp, Edegem, Belgium
- ORCID
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 2008-07
- Volume
- 178
- Issue
- 2
- Pages
- 197-202
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2110608739
- Cited by
- 289
- References
- 39
- Citations by year
- 2026: 2 · 2025: 10 · 2024: 9 · 2023: 13 · 2022: 22 · 2021: 14 · 2020: 13 · 2019: 22 · 2018: 13 · 2017: 14 · 2016: 14 · 2015: 25 · 2014: 37 · 2013: 17 · 2012: 20
- FWCI
- 6.23
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- American Journal of Respiratory and Critical Care Medicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
- Health Sciences › Dentistry › Oral Surgery › Temporomandibular Joint Disorders
- Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
- Keywords
- mandibular advancement device, sleep-disordered breathing, mild sleep apnea, apnea-hypopnea index, snoring, medication adherence, patient preferences, mandibular advancement therapy
- MeSH terms
- Analysis of Variance, Female, Humans, Male, Middle Aged, Orthodontic Appliances, Removable, Snoring, Polysomnography, Cross-Over Studies, Mandibular Advancement, Sleep Apnea, Obstructive
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of a Custom-made and a Thermoplastic Oral Appliance for the Treatment of Mild Sleep Apnea. https://app.cochat.ai/papers/10.1164/rccm.200701-114oc
- The paper
- Vanderveken, O. M., Devolder, A., Marklund, M., Boudewyns, A. N., Braem, M. J., Okkerse, W., Verbraecken, J. A., Franklin, K. A., De Backer, W. A., & Van de Heyning, P. H. (2008). Comparison of a Custom-made and a Thermoplastic Oral Appliance for the Treatment of Mild Sleep Apnea. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/rccm.200701-114oc
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.