Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 38 of the 39 references it cites were found in a registry or an index.

Comparison of a Custom-made and a Thermoplastic Oral Appliance for the Treatment of Mild Sleep Apnea

Vanderveken, Olivier M., Devolder, Annick, Marklund, Marie, Boudewyns, An N., Braem, Marc J., Okkerse, Walter, Verbraecken, Johan A., Franklin, Karl A., De Backer, Wilfried A., Van de Heyning, Paul H. · 2008 · American Journal of Respiratory and Critical Care Medicine

Abstract

Rationale: The efficacy of immediate adaptation of mandibular advancement devices made of thermoplastic material as a treatment option for sleep-disordered breathing (SDB) has been demonstrated in clinical studies. To date, there have been no studies comparing the efficacy of such prefabricated devices with custom-made devices. Objectives: Our purpose was to compare the efficacy of both types of devices in patients with SDB. Methods: A randomized controlled cross-over trial, comprising 4 months of treatment with a thermoplastic and a custom-made device, with a 1-month washout interval. Measurements and Main Results: A total of 35 patients (29 males; age, 49 ± 9 yr; apnea–hypopnea index [AHI], 13 ± 11 events/h; body mass index, 28 ± 4 kg/m2) completed the protocol. AHI was only reduced with the custom-made device (P = 0.005). In addition, this device reduced snoring to a greater extent than the thermoplastic device. The success rate was higher with the custom-made device (60 vs. 31%; P = 0.02). One-third of the patients demonstrated compliance failure with the thermoplastic device, mainly because of insufficient overnight retention. Total failure rate with the thermoplastic device was 69%, whereas the majority (63%) of these were successfully treated with the custom-made device. At the end of the study, 82% of the patients preferred the custom-made device, and 9% had no preference (P < 0.0001). Conclusions: In this study, a custom-made device turned out to be more effective than a thermoplastic device in the treatment of SDB. Our results suggest that the thermoplastic device cannot be recommended as a therapeutic option nor can it be used as a screening tool to find good candidates for mandibular advancement therapy.

Overview

Integrity signals

Registry

Crossref · 10.1164/rccm.200701-114oc

Cites

38 of 38 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 39 references

Research works printed but not linked: 8

  1. 1981, Lancet, 1, 862
  2. 2005, Cochrane Database Syst Rev, CD001004
  3. 2007, Sleep Breath, 11, 1
  4. 2006, Cochrane Database Syst Rev, CD004435
  5. 2004, Lancet, 360, 237
  6. 2005, Proc Am Thorac Soc, 2, A612
  7. 2002, Acta Otorhinolaryngol Belg, 56, 195
  8. 2002, Acta Otorhinolaryngol Belg, 56, 127

Cited by

See all 289

Metadata

Authors
Vanderveken, O. M., Devolder, A., Marklund, M., Boudewyns, A. N., Braem, M. J., Okkerse, W., Verbraecken, J. A., Franklin, K. A., De Backer, W. A., & Van de Heyning, P. H.
Affiliations
  • University of Antwerp (BE)
  • Antwerp University Hospital (BE)
  • Umeå University (SE)
  • Department of Otorhinolaryngology, Head and Neck Surgery
  • Department of Dentistry, University Hospital Antwerp, Edegem, Belgium
  • Department of Pulmonary Medicine, University Hospital Antwerp, Edegem, Belgium
Venue
American Journal of Respiratory and Critical Care Medicine
Published
2008-07
Volume
178
Issue
2
Pages
197-202
ISSN
  • 1073-449X (ISSN-L)
  • 1535-4970
OpenAlex
W2110608739
Cited by
289
References
39
Citations by year
2026: 2 · 2025: 10 · 2024: 9 · 2023: 13 · 2022: 22 · 2021: 14 · 2020: 13 · 2019: 22 · 2018: 13 · 2017: 14 · 2016: 14 · 2015: 25 · 2014: 37 · 2013: 17 · 2012: 20
FWCI
6.23
Type
journal article
Language
en
Open access
closed
Locations
  • American Journal of Respiratory and Critical Care Medicine (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
  • Health Sciences › Dentistry › Oral Surgery › Temporomandibular Joint Disorders
  • Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
Keywords
mandibular advancement device, sleep-disordered breathing, mild sleep apnea, apnea-hypopnea index, snoring, medication adherence, patient preferences, mandibular advancement therapy
MeSH terms
Analysis of Variance, Female, Humans, Male, Middle Aged, Orthodontic Appliances, Removable, Snoring, Polysomnography, Cross-Over Studies, Mandibular Advancement, Sleep Apnea, Obstructive

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of a Custom-made and a Thermoplastic Oral Appliance for the Treatment of Mild Sleep Apnea. https://app.cochat.ai/papers/10.1164/rccm.200701-114oc
The paper
Vanderveken, O. M., Devolder, A., Marklund, M., Boudewyns, A. N., Braem, M. J., Okkerse, W., Verbraecken, J. A., Franklin, K. A., De Backer, W. A., & Van de Heyning, P. H. (2008). Comparison of a Custom-made and a Thermoplastic Oral Appliance for the Treatment of Mild Sleep Apnea. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/rccm.200701-114oc

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.