Determination of Iron, Chromium, Cobalt, Nickel, and Scandium in Asbestos by Neutron Activation Analysis
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Iron, chromium, cobalt, nickel, and scandium were determined by neutron activation analysis (1) in the five UICC standard reference samples of asbestos, (2) in the individual samples of Canadian chrysotile which were blended to produce the reference sample chrysotile B, and (3) in a number of samples of crocidolite from both the North West Cape and Transvaal deposits in South Africa. High resolution 7-ray spectrometry was used to show that milling had not produced any significant change in the composition of the UICC standard reference samples.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The determination of iron in standard reference samples of asbestos revealed that their concentrations in amosite and crocidolite (28% and 27%, respectively) were greater than those in chrysotile (0–2%) [12].”
From Asbestos and Iron (2023) · cites this paper as [12]
Citations
Cites
Exposure to Metals in the Manufacture of Asbestos Textile Products
Cralley, L. J., Keenan, R. G., & LYNCH, J. R. (1967) · American Industrial Hygiene Association Journal · doi:10.1080/00028896709342664 · Cited by 26
Cited by
Mesotheliomata in Rats after Inoculation with Asbestos and Other Materials
Wagner, J. C., Berry, G., & Timbrell, V (1973) · British Journal of Cancer · doi:10.1038/bjc.1973.134 · Cited by 205
Mineral Fibers: Chemical, Physicochemical, and Biological Properties
Harington, J. S., Allison, A. C., & Badami, D. V. (1975) · Advances in Pharmacology · doi:10.1016/s1054-3589(08)60223-9 · Cited by 163
Preparation of the UICC Standard reference samples of asbestos
Timbrell, V., & Rendall, R. E. G. (1972) · Powder Technology · doi:10.1016/0032-5910(72)80032-9 · Cited by 114
Trace elements in hazardous mineral fibres
Bloise, A., Barca, D., Gualtieri, A. F., Pollastri, S., & Belluso, E. (2016) · Environmental Pollution · doi:10.1016/j.envpol.2016.06.007 · Cited by 90
Morgan, A. E., Holmes, A., & Gold, C. (1971) · Environmental Research · doi:10.1016/0013-9351(71)90016-8 · Cited by 58
Self-citation
Metadata
- Authors
- HOLMES, A., MORGAN, A., & SANDALLS, F. J.
- Affiliations
- a Health Physics and Medical Division, Atomic Energy Research Establishment, Harwell, Berkshire, United Kingdom
- ORCID
- MORGAN, A.
- Venue
- American Industrial Hygiene Association Journal
- Publisher
- Informa UK Limited
- Published
- 1971-05
- Volume
- 32
- Issue
- 5
- Pages
- 281-286
- ISSN
- 0002-8894 (ISSN-L)
- OpenAlex
- W2122848426
- Cited by
- 28
- References
- 1
- Citations by year
- 2024: 1 · 2023: 3 · 2022: 2 · 2020: 1 · 2016: 1
- FWCI
- 4.31
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- American Industrial Hygiene Association Journal (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Physics and Astronomy › Radiation › Nuclear Physics and Applications
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Occupational and environmental lung diseases
- Physical Sciences › Earth and Planetary Sciences › Geochemistry and Petrology › Mineralogy and Gemology Studies
- Keywords
- asbestos, chrysotile, crocidolite, iron, chromium, cobalt, nickel, scandium, trace element analysis
- MeSH terms
- Activation Analysis, Asbestos, Asbestosis, Canada, Chromium, Cobalt, Finland, Humans, Iron, Mesothelioma, Mining, Nickel, Pleural Neoplasms, Scandium, South Africa, Spectrometry, Gamma, Trace Elements, Zimbabwe
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.