CoChat

The 10-20 Electrode System and Cerebral Location

Homan, Richard W. · 1988 · American Journal of EEG Technology
Cited by 143

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

.In the three decades since it was introduced, the International 10-20 System of electrode placement has become the standard for locating scalp electrodes in EEG. The technique employs measurements of external cranial landmarks to locate the electrodes on the scalp. This process assumes a consistent correlation between scalp electrode locations and underlying cerebral structures.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/00029238.1988.11080272

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Research works printed but not linked: 14

  1. Binnie C. D., 1982, Clin. Neurophysiol., 53, 453, 10.1016/0013-4694(82)90010-4 · DOI
  2. Blume W. T., 1974, Clin. Neurophysiol., 36, 303, 10.1016/0013-4694(74)90172-2 · DOI
  3. Brodmann K., 1909, Vergleichende Lokalisationslehre Der Grosshirnrinde in Ihren Prinzipien Dargestellt auf Grund des Zellenbaues
  4. Buchsbaum M. S., 1982, Clin. Neurophysiol., 53, 237, 10.1016/0013-4694(82)90029-3 · DOI
  5. Celesia G. G., 1982, Clin. Neurophysiol., 54, 243, 10.1016/0013-4694(82)90174-2 · DOI
  6. Ehrlichman H., 1980, Psychophysiology, 17, 228, 10.1111/j.1469-8986.1980.tb00139.x · DOI · Paper page
  7. Hellström B., 1963, Clin. Neurophysiol., 15, 115, 10.1016/0013-4694(63)90044-0 · DOI
  8. Lemieux J. F., 1984, Clin. Neurophysiol., 58, 565, 10.1016/0013-4694(84)90046-4 · doi:10.1016/0013-4694(84)90046-4
  9. Matsui T., 1978, An Atlas of the Human Brain for Computerized Tomography.
  10. Morris H. H., 1986, Clin. Neurophysiol., 63, 107, 10.1016/0013-4694(86)90003-9 · DOI
  11. Rebert C. S., 1984, Biological Psychology, 19, 159, 10.1016/0301-0511(84)90034-6 · DOI
  12. Remond A., 1964, Clin. Neurophysiol., 17, 577, 10.1016/0013-4694(64)90193-2 · doi:10.1016/0013-4694(64)90193-2
  13. Silverman D., 1960, Clin. Neurophysiol., 12, 735, 10.1016/0013-4694(60)90119-X · DOI
  14. Thompson J. R., 1980, Anatomy of the Head and Neck.

Cited by

See all 143

Metadata

Authors
Homan, R. W.
Venue
American Journal of EEG Technology
Published
1988-12
Volume
28
Issue
4
Pages
269-279
ISSN
  • 0002-9238 (ISSN-L)
  • 2375-8600
OpenAlex
W2342822059
Cited by
143
References
1
FWCI
6.55
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The 10-20 Electrode System and Cerebral Location. https://app.cochat.ai/papers/10.1080/00029238.1988.11080272
The paper
Homan, R. W. (1988). The 10-20 Electrode System and Cerebral Location. American Journal of EEG Technology. https://doi.org/10.1080/00029238.1988.11080272

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.