CoChat

Determination of Estrogens in Water Samples by Ionic Liquid-Based Dispersive Liquid-Liquid Microextraction Combined with High Performance Liquid Chromatography

Wu, Cui-Qin, Chen, Di-Yun, Feng, Yin-Si, Deng, Hong-Mei, Liu, Yong-Hui, Zhou, Ai-Ju · 2012 · Analytical Letters
Cited by 26

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Using 1-hexyl-3-methylimidazolium hexafluorophosphate ([C6MIM][PF6]) ionic liquid as extraction solvent, five estrogens including estrone (E1), 17β-estradiol (E2), estriol (E3), 17α -ethynylestradiol (EE2), and diethylstilbestrol (DES) in water samples were determined by dispersive liquid-liquid microextraction (DLLME) followed by high performance liquid chromatography with a photodiode array detector and a fluorescence detector (HPLC-DAD-FLD). The extraction procedure was induced by the formation of cloudy solution, which was composed of fine drops of [C6MIM][PF6] dispersed entirely into the sample solution with the help of a disperser solvent (acetone). Parameters including both extraction and disperser solvents and their volumes, extraction and centrifugal time, sample pH, and salt effect were investigated and optimized. Under the optimized conditions, 110–349 fold enrichment factors of analytes were obtained. The calibration curves were linear in the concentration range of 0.2–100 µg L−1 for E2, E3, and EE2 detected with FLD, and 1–100 µg L−1 for E1 and DES detected with DAD. The correlation coefficient of the calibration curve was between 0.9990 and 0.9997. The limits of detection (LOD, S/N = 3) for the five estrogens were in the range of 0.08–0.5 µg L−1. The relative standard deviations (RSD) for six replication experiments at the concentration of 5.0 µg L−1 were ≤5.7%. The proposed method was applied to the analysis of three water samples from different sources (river water, waste water, and sea water). The relative recoveries of spiked water samples are satisfied with 89.3–102.4% and 88.7–105.2% at two different concentration levels of 5.0 and 50.0 µg L−1, respectively.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/00032719.2012.680086

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 26

Metadata

Authors
Wu, C.-Q., Chen, D.-Y., Feng, Y.-S., Deng, H.-M., Liu, Y.-H., & Zhou, A.-J.
Venue
Analytical Letters
Published
2012-09-15
Volume
45
Issue
14
Pages
1995-2005
ISSN
  • 0003-2719 (ISSN-L)
  • 1532-236X
OpenAlex
W1989801030
Cited by
26
References
3
FWCI
3.92
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Determination of Estrogens in Water Samples by Ionic Liquid-Based Dispersive Liquid-Liquid Microextraction Combined with High Performance Liquid Chromatography. https://app.cochat.ai/papers/10.1080/00032719.2012.680086
The paper
Wu, C.-Q., Chen, D.-Y., Feng, Y.-S., Deng, H.-M., Liu, Y.-H., & Zhou, A.-J. (2012). Determination of Estrogens in Water Samples by Ionic Liquid-Based Dispersive Liquid-Liquid Microextraction Combined with High Performance Liquid Chromatography. Analytical Letters. https://doi.org/10.1080/00032719.2012.680086

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.