CoChat

Vortex-Assisted Liquid-Liquid Microextraction Based on a Hydrophobic Deep Eutectic Solvent for the Highly Efficient Determination of Sudan I in Food Samples

Zhang, Kaige, Liu, Chuang, Li, Shuangying, Wang, Yunhe, Zhu, Guifen, Fan, Jing · 2020 · Analytical Letters
Cited by 37

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

As a new class of green solvents, hydrophobic deep eutectic solvents (DESs) have attracted considerable attention for liquid phase microextraction. In this study, a hydrophobic DES composed of trioctylmethylammonium chloride and oleic acid was successfully applied for the vortex-assisted liquid-liquid microextraction (VA-LLME) of Sudan I in food samples coupled with high performance liquid chromatography with diode array detection (HPLC-DAD). Trioctylmethylammonium chloride and oleic acid at a molar ratio of 1:2 showed higher extraction recovery for Sudan I than other DESs. The deep eutectic solvent was prepared and characterized by Fourier transform infrared spectroscopy (FT-IR) and proton nuclear magnetic resonance spectroscopy (1H NMR). The parameters affecting extraction recovery were optimized in detail. This hydrophobic DES based VA-LLME technique exhibited a high extraction recovery close to 100% at room temperature within 3 min. Under the optimized conditions, wide linear ranges were acquired with r2 equal to 0.9992. The limit of detection was 0.3 µg kg−1. The inter day and intra-day precision values were less than 5.4%. This hydrophobic DES based VA-LLME technique was successfully applied for the determination of Sudan I from duck blood and chili power samples with the satisfactory recoveries from 83.4 to 114.1% and relative standard deviations from 1.5 to 7.6%. In addition, the analytical parameters of this method and other liquid phase microextraction methods were compared.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/00032719.2019.1700422

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Research works printed but not linked: 18

  1. 10.1016/j.chroma.2011.05.096 · DOI · Paper page
  2. Commission of the European Communities, 2005, Official Journal of the European Union, 135
  3. 10.1016/j.talanta.2011.01.043 · doi:10.1016/j.talanta.2011.01.043
  4. 10.1016/j.chroma.2019.01.022 · DOI · Paper page
  5. 10.1080/00032719.2018.1467434 · DOI
  6. 10.1016/j.chroma.2011.04.014 · DOI
  7. 10.1016/j.microc.2019.104073 · DOI
  8. 10.1080/00032719.2019.1643358 · DOI
  9. 10.1039/C7AY01033H · DOI
  10. 10.1039/C9RA01405E · DOI · Paper page
  11. 10.1016/j.foodchem.2017.08.100 · DOI
  12. 10.1016/j.molliq.2018.09.072 · DOI · Paper page
  13. 10.1021/cr300162p · DOI · Paper page
  14. Stiborová M., 2002, Cancer Research, 62, 5678
  15. 10.1039/C6AY00053C · DOI
  16. 10.1016/j.talanta.2009.11.005 · DOI · Paper page
  17. 10.1016/j.foodchem.2014.10.091 · DOI
  18. 10.1016/j.chroma.2018.12.063 · DOI

Metadata

Authors
Zhang, K., Liu, C., Li, S., Wang, Y., Zhu, G., & Fan, J.
Venue
Analytical Letters
Published
2019-12-11
Volume
53
Issue
8
Pages
1204-1217
ISSN
  • 0003-2719 (ISSN-L)
  • 1532-236X
OpenAlex
W2995683815
Cited by
37
References
6
FWCI
2.69
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Vortex-Assisted Liquid-Liquid Microextraction Based on a Hydrophobic Deep Eutectic Solvent for the Highly Efficient Determination of Sudan I in Food Samples. https://app.cochat.ai/papers/10.1080/00032719.2019.1700422
The paper
Zhang, K., Liu, C., Li, S., Wang, Y., Zhu, G., & Fan, J. (2020). Vortex-Assisted Liquid-Liquid Microextraction Based on a Hydrophobic Deep Eutectic Solvent for the Highly Efficient Determination of Sudan I in Food Samples. Analytical Letters. https://doi.org/10.1080/00032719.2019.1700422

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.