A High-Sensitive Glucose Amperometric Biosensor Based on Prussian Blue Modified Electrodes
Abstract
A first generation amperometric glucose biosensor based on Prussian Blue modified electrodes was developed. Besides exception of noble metals (platinum as usual) the developed biosensor possessed high sensitivity. Linear response dependence on analyte concentration was observed in a range of 10−6 − 5·10−3 M glucose. The current density produced by addition of 10−6 M glucose was 0.18 μ A/cm2. Hydrogen peroxide produced via enzyme reaction was detected by electroreduction. Owing to that reason the biosensor response became independent of the presence of reductants (ascorbate for example). The developed amperometric biosensor was expected to obey requirements for non-invasive diagnostics. There are not principle limits of using other oxidases for Prussian Blue based amperometric biosensor development. Thus one can develop such biosensors for cholesterol, alcohol, glycerol, amino acids ets.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Prussian Blue Analogues for Sodium‐Ion Batteries: Past, Present, and Future
Peng, J., Zhang, W., Liu, Q., Wang, J., Chou, S., Liu, H., & Dou, S. (2022) · Advanced Materials · doi:10.1002/adma.202108384 · Cited by 849
Sensor and biosensor preparation, optimisation and applications of Prussian Blue modified electrodes
Ricci, F., & Palleschi, G. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.12.001 · Cited by 781
Karyakin, A. A., Karyakina, E. E., & Gorton, L. (2000) · Analytical Chemistry · doi:10.1021/ac990801o · Cited by 419
Self-citationCatalytically Synthesized Prussian Blue Nanoparticles Defeating Natural Enzyme Peroxidase
Komkova, M. A., Karyakina, E. E., & Karyakin, A. A. (2018) · Journal of the American Chemical Society · doi:10.1021/jacs.8b05223 · Cited by 300
Self-citationKaryakin, A. A., & Karyakina, E. E. (1999) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(99)00154-9 · Cited by 283
Self-citation
Metadata
- Authors
- Karyakin, A. A., Gitelmacher, O. V., & Karyakina, E. E.
- Venue
- Analytical Letters
- Publisher
- Informa UK Limited
- Published
- 1994-12
- Volume
- 27
- Issue
- 15
- Pages
- 2861-2869
- ISSN
- 0003-2719 (ISSN-L)
- 1532-236X
- OpenAlex
- W2145252373
- Cited by
- 179
- References
- 0
- FWCI
- 2.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A High-Sensitive Glucose Amperometric Biosensor Based on Prussian Blue Modified Electrodes. https://app.cochat.ai/papers/10.1080/00032719408000297
- The paper
- Karyakin, A. A., Gitelmacher, O. V., & Karyakina, E. E. (1994). A High-Sensitive Glucose Amperometric Biosensor Based on Prussian Blue Modified Electrodes. Analytical Letters. https://doi.org/10.1080/00032719408000297
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.