Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 179

The DOI matches its Crossref record.

A High-Sensitive Glucose Amperometric Biosensor Based on Prussian Blue Modified Electrodes

Karyakin, Arkady A., Gitelmacher, Olga V., Karyakina, Elena E.·1994·Analytical Letters

Abstract

A first generation amperometric glucose biosensor based on Prussian Blue modified electrodes was developed. Besides exception of noble metals (platinum as usual) the developed biosensor possessed high sensitivity. Linear response dependence on analyte concentration was observed in a range of 10−6 − 5·10−3 M glucose. The current density produced by addition of 10−6 M glucose was 0.18 μ A/cm2. Hydrogen peroxide produced via enzyme reaction was detected by electroreduction. Owing to that reason the biosensor response became independent of the presence of reductants (ascorbate for example). The developed amperometric biosensor was expected to obey requirements for non-invasive diagnostics. There are not principle limits of using other oxidases for Prussian Blue based amperometric biosensor development. Thus one can develop such biosensors for cholesterol, alcohol, glycerol, amino acids ets.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/00032719408000297

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 179

Metadata

Authors
Karyakin, A. A., Gitelmacher, O. V., & Karyakina, E. E.
Venue
Analytical Letters
Published
1994-12
Volume
27
Issue
15
Pages
2861-2869
ISSN
  • 0003-2719 (ISSN-L)
  • 1532-236X
OpenAlex
W2145252373
Cited by
179
References
0
FWCI
2.93
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A High-Sensitive Glucose Amperometric Biosensor Based on Prussian Blue Modified Electrodes. https://app.cochat.ai/papers/10.1080/00032719408000297
The paper
Karyakin, A. A., Gitelmacher, O. V., & Karyakina, E. E. (1994). A High-Sensitive Glucose Amperometric Biosensor Based on Prussian Blue Modified Electrodes. Analytical Letters. https://doi.org/10.1080/00032719408000297

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.