The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Nitric acid digestion and multi‐element analysis of plant material by inductively coupled plasma spectrometry
Abstract
Inductively coupled plasma spectrometry (ICPS) was used for the simultaneous determination of P, K, S, Ca, Mg, Na, Al, Cu, Zn, Mn, Fe, Co, Mo and B in the nitric acid soluble portion of a variety of plant materials. Conditions for pre‐digestion, digestion and the requirement to grind cereal grain were investigated. Digestion with nitric and perchloric acids caused loss of K (due to the low solubility of potassium perchlorate) and B (due to volatilization). The accuracy of Fe and Na determinations using nitric acid digestion was dependent upon the type of plant material. The accuracy and precision of the proposed digestion and analytical procedure was confirmed by co‐operation in an interlaboratory quality assurance program using a variety of standard reference plant materials, and the analysis of National Bureau of Standards, Standard Reference Material 1571 (orchard leaves).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Digestion of plant tissue for analysis by ICP emission spectroscopy
Huang, C. L., & Schulte, E. E. (1985) · Communications in Soil Science and Plant Analysis · doi:10.1080/00103628509367657 · Cited by 455
Dahlquist, R. L., & Knöll, J. (1978) · Applied Spectroscopy · doi:10.1366/000370278774331828 · Cited by 419
A nitric acid plant tissue digest method for use with inductively coupled plasma spectrometry
Havlin, J. L., & Soltanpour, P. N. (1980) · Communications in Soil Science and Plant Analysis · doi:10.1080/00103628009367096 · Cited by 270
McQuaker, N. R., Brown, D. F., & Kluckner, P. D. (1979) · Analytical Chemistry · doi:10.1021/ac50043a071 · Cited by 259
Cresser, M. S., & Parsons, J. W. (1979) · Analytica Chimica Acta · doi:10.1016/s0003-2670(01)84273-2 · Cited by 172
Evaluation of wet and dry digestion methods for boron determination in plant samples by icp‐aes
Gestring, W. D., & Soltanpour, P. N. (1981) · Communications in Soil Science and Plant Analysis · doi:10.1080/00103628109367190 · Cited by 22
Cited by
Biochar reduces the bioavailability and phytotoxicity of heavy metals
Park, J. H., Choppala, G. K., Bolan, N. S., Chung, J. W., & Chuasavathi, T. (2011) · Plant and Soil · doi:10.1007/s11104-011-0948-y · Cited by 1,157
“The plant materials were analysed for metal content using nitric acid digestion (Zarcinas et al. 1987).”
MethodSampling, Handling, and Analyzing Plant Tissue Samples
Jones, J. B., & Case, V. W. (1990) · SSSA Book Series · doi:10.2136/sssabookser3.3ed.c15 · Cited by 1,047
Agriculture, Forestry and Fisheries
Hill, B., Greer, A., Heckelei, T., & Witze, P. (2004) · Handbook of Public Policy in Europe · doi:10.1057/9780230522756_17 · Cited by 644
Tavakkoli, E., Rengasamy, P., & McDonald, G. K. (2010) · Journal of Experimental Botany · doi:10.1093/jxb/erq251 · Cited by 620
Zhu, Y. L., Pilon-Smits, E. A. H., Tarun, A. S., Weber, S. U., Jouanin, L., & Terry, N. (1999) · Plant Physiology · doi:10.1104/pp.121.4.1169 · Cited by 576
Metadata
- Authors
- Zarcinas, B. A., Cartwright, B., & Spouncer, L. R.
- Venue
- Communications in Soil Science and Plant Analysis
- Publisher
- Informa UK Limited
- Published
- 1987-01
- Volume
- 18
- Issue
- 1
- Pages
- 131-146
- ISSN
- 0010-3624 (ISSN-L)
- 1532-2416
- OpenAlex
- W2085568111
- Cited by
- 867
- References
- 7
- FWCI
- 2.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.