CoChat

Vigilance on the civil flight deck: incidence of sleepiness and sleep during long-haul flights and associated changes in physiological parameters

Wright, Nicola, McGown, Amanda · 2001 · Ergonomics
Cited by 123

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

The study investigated sleepiness and sleep in aircrew during long-haul flights. The objectives were to identify loss of alertness and to recommend a practical approach to the design of an alerting system to be used by aircrew to prevent involuntary sleep. The flights were between London and Miami, covering both day- and night-time sectors, each with a duration of approximately 9 h. The subjects were 12 British Airways pilots. Various physiological variables were measured that could potentially be used to indicate the presence of drowsiness and involuntary sleep: brain electrical activity (electroencephalogram, EEG), eye movements via the electro-oculogram (EOG), wrist activity, head movements and galvanic skin resistance. The EEG and EOG identified sleepiness and sleep, as well as being potential measures on which to base an alarm system. Ten pilots either slept or showed evidence of sleepiness as assessed by the EEG and EOG. Many of the episodes of sleepiness lasted < 20 s, which could mean that the subjects were unaware of their occurrence and of the potential consequences on performance and vigilance. All physiological parameters showed changes during sleep, although only the EEG and EOG were modified by sleepiness. During sleep, skin resistance was increased, and wrist activity and head movements were absent for long periods. The study indicated that the measurement of eye movements (either alone or in combination with the EEG), wrist activity or head movement may be used as the basis of an alarm system to prevent involuntary sleep. Skin resistance is considered to be unsuitable, however, being related in a more general way to fatigue rather than to sleep episodes. The optimal way to monitor the onset of sleep would be to measure eye movements; however, this is not feasible in the flight deck environment at the present time due to the intrusive nature of the recording methodology. Wrist activity is therefore recommended as the basis of an alertness alarm. Such a device would alert the pilot after approximately 4-5 min of wrist inactivity, since this duration has been shown by the present study to be associated with sleep. The possibility that sleep inertia (reduced alertness immediately after awakening from sleep) could follow periods of sleep lasting 5 min needs to be considered. The findings reported here might be applicable to other occupational environments where fatigue and sleepiness are known to occur.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/00140130150203893

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 123

Metadata

Authors
Wright, N., & McGown, A.
Venue
Ergonomics
Published
2001-01
Volume
44
Issue
1
Pages
82-106
ISSN
  • 0014-0139 (ISSN-L)
  • 1366-5847
OpenAlex
W2110318297
Cited by
123
References
2
FWCI
4.89
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Vigilance on the civil flight deck: incidence of sleepiness and sleep during long-haul flights and associated changes in physiological parameters. https://app.cochat.ai/papers/10.1080/00140130150203893
The paper
Wright, N., & McGown, A. (2001). Vigilance on the civil flight deck: incidence of sleepiness and sleep during long-haul flights and associated changes in physiological parameters. Ergonomics. https://doi.org/10.1080/00140130150203893

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.