Spectral Analysis of Sinus Arrhythmia during Mental Loading
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A technique is presented for digitally processing cardiac intervals to produce the low-pass filtered cardiac event sequence (LPFCES), a regularly sampled (in time) band-limited signal, representing in a standard form the information contained in the cardiac intervals. The technique takes into account the physiological mechanisms of information transfer across the peacemaker, and thereby produces a signal that has a physiological counterpart: autonomic activity converging on the sino-atrial node. Sinus arrhythmia (SA) is then defined quantitatively as those harmonic components of the cardiac event sequence which correspond to the signal that modulates that event sequence (i.e., the converging autonomic activity). SA is scored by calculating the average total power (ATP) of the LPFCES, as well as the contribution of changes in average band power (ABP) of various spectral bands to the ATP changes. This scoring technique is shown to give a reliable indication of mental loading (and possibly reserve capacity) in decision-making tasks. Possible mechanisms of reduced SA with mental loading are explored.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An algorithm for the machine calculation of complex Fourier series
Cooley, J. W., & Tukey, J. W. (1965) · Mathematics of Computation · doi:10.1090/s0025-5718-1965-0178586-1 · Cited by 13,154
Cited by
Cardiovascular neural regulation explored in the frequency domain.
Malliani, A., Pagani, M., Lombardi, F., & Cerutti, S. (1991) · Circulation · doi:10.1161/01.cir.84.2.482 · Cited by 3,569
Respiratory sinus arrhythmia in humans: how breathing pattern modulates heart rate
Hirsch, J. A., & Bishop, B. (1981) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1981.241.4.h620 · Cited by 1,105
Heart Rate Variability ? A Historical Perspective
Billman, G. E. (2011) · Frontiers in Physiology · doi:10.3389/fphys.2011.00086 · Cited by 786
“Beginning in the early 1970s several groups applied power spectral analysis to investigate the physiological basis for the individual frequency components that compose the periodic variations in heart rate (Hyndman et al., 1971; Sayers, 1973; Chess et al., 1975; Hyndman and Gregory, 1975; Peñáz et al., 1978; Akselrod…”
BackgroundMethodInfluentialImportant influence of respiration on human R-R interval power spectra is largely ignored
Brown, T. E., Beightol, L. A., Koh, J., & Eckberg, D. L. (1993) · Journal of Applied Physiology · doi:10.1152/jappl.1993.75.5.2310 · Cited by 770
Beat to beat variability in cardiovascular variables: Noise or music?
Appel, M. L., Berger, R. D., Saul, J. P., Smith, J. M., & Cohen, R. J. (1989) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(89)90408-7 · Cited by 549
Metadata
- Authors
- HYNDMAN, B. W., & GREGORY, J. R.
- Venue
- Ergonomics
- Publisher
- Informa UK Limited
- Published
- 1975-05
- Volume
- 18
- Issue
- 3
- Pages
- 255-270
- ISSN
- 0014-0139 (ISSN-L)
- 1366-5847
- OpenAlex
- W2022496931
- Cited by
- 98
- References
- 1
- FWCI
- 2.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Spectral Analysis of Sinus Arrhythmia during Mental Loading. https://app.cochat.ai/papers/10.1080/00140137508931460
- The paper
- HYNDMAN, B. W., & GREGORY, J. R. (1975). Spectral Analysis of Sinus Arrhythmia during Mental Loading. Ergonomics. https://doi.org/10.1080/00140137508931460
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.