A comparison between methods of measuring anaerobic work capacity
The DOI matches its Crossref record.
Abstract
The purpose of this study was to determine the relationship between anaerobic work capacity (AWC) and anaerobic capacity (AC) from the Critical Power (CP) and ‘Wingate’ tests, respectively. A secondary purpose was to determine the reliability of AWC and CP. Twenty-five females (mean±s.d. = 21·88±2·49 years) volunteered to perform a ‘Wingate’ test and two Critical Power tests all on separate days. Anaerobic capacity was defined as the total work performed during the 30-second ‘Wingate’ test. The relationship between work limit (total work to exhaustion) and time limit (total time to exhaustion), calculated for each of the three work bouts of the CP test, was linear (r 2 =0·98−1·00) for all of the subjects. The slope and Y intercept of this relationship represented CP and AWC, respectively. Anaerobic capacity and AWC were significantly (p<0·05) related (r=0·74). In addition, there were no significant (p>0·05) differences between the test-retest means for CP or AWC. Test-retest correlations for CP (r=0·94) and AWC (r=0·87) were significant. When considered in conjunction with previous investigations, the results of this study indicated that the Critical Power test was a valid and reliable technique for determining anaerobic capabilities as well as the maximal rate of fatigueless work.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Reliability of Power in Physical Performance Tests
Hopkins, W. G., Schabort, E. J., & Hawley, J. A. (2001) · Sports Medicine · doi:10.2165/00007256-200131030-00005 · Cited by 825
The Critical Power Concept: A Review
Hill, D. W. (1993) · Sports Medicine · doi:10.2165/00007256-199316040-00003 · Cited by 418
Methods to Determine Aerobic Endurance
Bosquet, L., L??ger, L., & Legros, P. (2002) · Sports Medicine · doi:10.2165/00007256-200232110-00002 · Cited by 279
Kendall, K. L., Smith, A. E., Graef, J. L., Fukuda, D. H., Moon, J. R., Beck, T. W., Cramer, J. T., & Stout, J. R. (2009) · Journal of Strength and Conditioning Research · doi:10.1519/jsc.0b013e3181b1fd1f · Cited by 51
“The critical power (CP) test, which measures both CP and anaerobic working capacity (AWC), has been shown to be both reliable in measuring aerobic and anaerobic parameters as well as sensitive to changes with high-intensity exercise training (18,31,42).”
BackgroundEFFECT OF TWO AND FIVE DAYS OF CREATINE LOADING ON ANAEROBIC WORKING CAPACITY IN WOMEN
ECKERSON, J. M., STOUT, J. R., MOORE, G. A., STONE, N. J., NISHIMURA, K., & TAMURA, K. (2004) · Journal of Strength and Conditioning Research · doi:10.1519/00124278-200402000-00025 · Cited by 2
Metadata
- Authors
- NEBELSICK-GULLETT, L. J., HOUSH, T. J., JOHNSON, G. O., & BAUGE, S. M.
- Venue
- Ergonomics
- Publisher
- Informa UK Limited
- Published
- 1988-10
- Volume
- 31
- Issue
- 10
- Pages
- 1413-1419
- ISSN
- 0014-0139 (ISSN-L)
- 1366-5847
- OpenAlex
- W1991955887
- Cited by
- 84
- References
- 0
- FWCI
- 1.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A comparison between methods of measuring anaerobic work capacity. https://app.cochat.ai/papers/10.1080/00140138808966785
- The paper
- NEBELSICK-GULLETT, L. J., HOUSH, T. J., JOHNSON, G. O., & BAUGE, S. M. (1988). A comparison between methods of measuring anaerobic work capacity. Ergonomics. https://doi.org/10.1080/00140138808966785
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.