Validity and Reliability of Wearable Sensors for Joint Angle Estimation: A Systematic Review
Open accessAbstract
Motion capture systems are recognized as the gold standard for joint angle calculation. However, studies using these systems are restricted to laboratory settings for technical reasons, which may lead to findings that are not representative of real-life context. Recently developed commercial and home-made inertial measurement sensors (M/IMU) are potentially good alternatives to the laboratory-based systems, and recent technology improvements required a synthesis of the current evidence. The aim of this systematic review was to determine the criterion validity and reliability of M/IMU for each body joint and for tasks of different levels of complexity. Five different databases were screened (Pubmed, Cinhal, Embase, Ergonomic abstract, and Compendex). Two evaluators performed independent selection, quality assessment (consensus-based standards for the selection of health measurement instruments [COSMIN] and quality appraisal tools), and data extraction. Forty-two studies were included. Reported validity varied according to task complexity (higher validity for simple tasks) and the joint evaluated (better validity for lower limb joints). More studies on reliability are needed to make stronger conclusions, as the number of studies addressing this psychometric property was limited. M/IMU should be considered as a valid tool to assess whole body range of motion, but further studies are needed to standardize technical procedures to obtain more accurate data.
AI snapshot
Written from the paper’s full text.
TL;DR
This systematic review of 42 studies found that inertial measurement units (M/IMUs) are generally valid for joint angle estimation, with validity varying by task complexity and joint. Reliability evidence was limited, and further standardization and ecological studies are needed before extensive use outside the laboratory.
Key findings
- Forty-two studies were included: 39 addressed validity and 15 addressed reliability; 556 subjects were tested overall (508 for validity and 184 for reliability).
- Criterion validity evidence was strong for the trunk, pelvis, hip, knee, and ankle; conflicting for the shoulder, elbow, and wrist; and moderate for the neck. Validity was better for simple tasks and lower limb joints, while complex movements and transverse-plane rotations generally showed poorer results.
- Reliability evidence was limited: all 15 reliability studies assessed intra-rater reliability, with only four also assessing inter-rater reliability, and reliability was evaluated in only one to three studies per joint.
- Methodological quality was variable: MacDermid scores ranged from 41% to 92% (mean 64.5 ± 12.9%), with 11 high-quality, 22 moderate-quality, and 9 low-quality studies.
Methods
- Systematic review following PRISMA guidelines and prospectively registered with PROSPERO (CRD42018104775); five databases were screened (PubMed, CinAHL, Ergonomic abstract, Compendex, and EMBASE), yielding 943 articles and 42 included studies.
- Inclusion criteria required human subjects aged 18–65 years, comparison of M/IMUs to a gold standard for criterion validity or repeated M/IMU measurements for reliability, publication after 2005, and French or English language.
- Two reviewers independently performed selection, quality assessment using COSMIN and the MacDermid critical appraisal tool, and data extraction; due to heterogeneity, results were synthesized descriptively without meta-analysis.
Limitations
- The authors state that all included studies were performed in laboratory settings, so findings cannot be directly generalized to real-life or outside-laboratory use; lack of standardization in protocols, calibration procedures, biomechanical models, and sensor placements prevented identification of main error sources.
- The authors also state that only 12 high-quality studies were included, sample sizes ranged from 1 to 38 participants (below the recommended 50), and heterogeneity of movements prevented quantitative meta-analysis.
- Evident from the text: reliability conclusions are constrained by the small number of studies per joint, most included studies assessed only simple planar movements or locomotor tasks, and the review focused on healthy adults aged 18–65, leaving pathological populations and ecological settings unaddressed.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
0 of 85 cited sources checked · 0 supported · 0 flagged
- Findingcitation
The majority of studies reported r and RMSE for validity and ICC or CMC for reliability.
“The majority of the studies reported r and RMSE for validity (only one article used m-estimators) and ICC or CMC for reliability [28].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [28] Bouvier, 2015, Upper Limb Kinematics Using Inertial and Magnetic Sensors: Comparison of Sensor-to-Segment Calibrations, Sensors source
Not checked in the free run.
- Findingown data
The number of studies addressing reliability was limited.
“More studies on reliability are needed to make stronger conclusions, as the number of studies addressing this psychometric property was limited.”
Quote in the paperSubstantial claim - Findingnone given
Reported validity varied according to task complexity, with higher validity for simple tasks.
“Reported validity varied according to task complexity (higher validity for simple tasks)”
Quote in the paperSubstantial claim - Findingown data
The knee and hip were the most investigated joints for validity (15 and 13 studies, respectively).
“The knee and the hip were the most investigated joints for validity (respectively 15 and 13 studies).”
Quote in the paperNot a substantial claim - Findingown data
Reliability was only evaluated in one to three studies per joint.
“Reliability was only evaluated in one to three studies per joint.”
Quote in the paperNot a substantial claim
- Findingreasoning
The body of evidence for the shoulder joint is conflicting (12 studies, 87 participants).
“The body of evidence for the shoulder joint is considered to be ‘’conflicting’’ (12 studies, total of 87 participants [one to 19 participants/study]).”
Quote in the paperSubstantial claim - Findingreasoning
The body of evidence for the elbow joint is conflicting (10 studies, 71 participants).
“The body of evidence for the elbow joint is considered to be ‘’conflicting’’ (10 studies, total 71 participants [one to 19 participants/study]).”
Quote in the paperNot a substantial claim - Findingown data
Shoulder heterogeneity of results (RMSE 0.2-64.5° and r 0.69-1.00) and movements made it difficult to conclude validity.
“Despite a larger number of studies published for this joint, heterogeneity of results (RMSE between 0.2 and 64.5° and r from 0.69 to 1.00) and movements performed made it difficult to conclude the validity of using M/IMU systems for movement at this joint [31,32,33,34,35,37,38,39,42,43,44,45].”
Quote in the paperSubstantial claim0 of 3 sources checked- cites [31] Ertzgaard, 2016, A new way of assessing arm function in activity using kinematic Exposure Variation Analysis and portable inertial sensors—A validity study, Man. Ther. source
Not checked in the free run.
- cites [32] Fantozzi, 2016, Assessment of three-dimensional joint kinematics of the upper limb during simulated swimming using wearable inertial-magnetic measurement units, J. Sports Sci. source
Not checked in the free run.
- cites [33] Pons, 2013, A novel motion tracking system for evaluation of functional rehabilitation of the upper limbs, Neural Regen. Res.
Not checked in the free run.
- Findingcitation
Trunk validity was similar across all movement planes and axes.
“Validity was similar across all movement planes and axes [34,36,37,38,41,46,47,48,49,50,51].”
Quote in the paperNot a substantial claim0 of 3 sources checked- cites [34] Godwin, 2009, Accuracy of inertial motion sensors in static, quasistatic, and complex dynamic motion, J. Biomech. Eng. source
Not checked in the free run.
- cites [36] Plamondon, 2007, Evaluation of a hybrid system for three-dimensional measurement of trunk posture in motion, Appl. Ergon. source
Not checked in the free run.
- cites [37] Robert-Lachaine, X., Mecheri, H., Larue, C., and Plamondon, A. (2016). Validation of inertial measurement units with an optoelectronic system for whole-body motion analysis. Med. Biol. Eng. Comput. source
Not checked in the free run.
- Findingown data
Elbow validity tended to decrease with increasing movement complexity.
“and validity tended to decrease with increasing movement complexity (r ≥ 0.93 compared to r ≥ 0.68 for complex movements).”
Quote in the paperNot a substantial claim - Findingown data
Wrist radial and ulnar deviation showed poorer results than other movements.
“Radial and ulnar deviation showed poorer results than any other movement (RMSE ranging from 3 to 30° for ulnar deviation compared to 3 to 20° for flexion), regardless of the movements performed.”
Quote in the paperNot a substantial claim - Findingown data
The body of evidence for the wrist joint is conflicting (6 studies, 51 participants).
“The body of evidence for the wrist joint is considered to be ‘’conflicting’’ (6 studies, total of 51 participants [one to 19 participants/study]).”
Quote in the paperNot a substantial claim - Findingown data
Elbow pro-supination showed poorer correlations than flexion-extension.
“Pro-supination (r between 0.68 and 0.99) showed poorer correlations than flexion–extension (r between 0.85 and 0.99)”
Quote in the paperNot a substantial claim - Findingnone given
Ankle RMSE increased with movement speed (slow walking 1.2-2.0° to running 15.8°).
“RMSE results increased with movement speed (different walking speed vs. running; RMSE of 1.2 to 2.0 for a slow walking speed to 15.8° for running).”
Quote in the paperNot a substantial claim - Findingown data
Ankle rotation and inversion/eversion showed poorer validity than dorsiflexion/plantar flexion, especially for small ranges of movement.
“Also, rotation and inversion/eversion showed poorer validity than dorsiflexion/plantar flexion, especially for small ranges of movement (RMSE as high as 18.8 for rotation and 11.2 for inversion/eversion).”
Quote in the paperSubstantial claim - Findingreasoning
Knee abduction/adduction were less valid than knee flexion and extension.
“Knee abduction/adduction, which are movements with very small range of motion (ROM), were less valid (RMSE higher than 5°) than knee flexion and extension, which presented high validity (majority of studies with r ≥ 0.8).”
Quote in the paperSubstantial claim - Findingown data
The body of evidence for scapula reliability is limited (one study, 20 participants, one HQ study).
“The body of evidence for the scapula is considered to be limited (one study, total of 20 participants, one HQ study).”
Quote in the paperNot a substantial claim - Findingcitation
The body of evidence for pelvis reliability is moderate (one study, one participant, one HQ study).
“The body of evidence for the pelvis is considered to be moderate (one study, total of one participant, one HQ study).”
Quote in the paperNot a substantial claim - Findingown data
The body of evidence for hip reliability is moderate (three studies, 70 participants, one HQ and two MQ studies).
“The body of evidence for the hip is considered to be moderate (three studies, total of 70 participants [20 to 26 participants/study], one HQ and two MQ study).”
Quote in the paperNot a substantial claim - Findingcitation
Both wrist reliability studies presented good to excellent intra-rater reliability for all joint movements (CMC and ICC 0.79 to 0.96).
“Both studies presented good to excellent intra-rater reliability for all joint movements (CMC and ICC between 0.79 to 0.96) [28,66].”
Quote in the paperNot a substantial claim0 of 2 sources checked- cites [28] Bouvier, 2015, Upper Limb Kinematics Using Inertial and Magnetic Sensors: Comparison of Sensor-to-Segment Calibrations, Sensors source
Not checked in the free run.
- cites [66] Schiefer, 2015, A technical support tool for joint range of motion determination in functional diagnostics—An inter-rater study, J. Occup. Med. Toxicol. source
Not checked in the free run.
- Findingcitation
All pelvis movements showed good reliability with an absolute error of less than 1.2°.
“All pelvis movements showed good reliability with an absolute error of less than 1.2° [42].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [42] Bugane, 2014, Estimation of pelvis kinematics in level walking based on a single inertial sensor positioned close to the sacrum: Validation on healthy subjects with stereophotogrammetric system, Biomed. Eng. Online source
Not checked in the free run.
- Findingown data
The present review's results are opposite to the previous systematic review's finding that upper limb joints had better results than lower limb joints.
“This is opposite to our results.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [12] Williams, 2010, The use of inertial sensors system for human motion analysis, Phys. Ther. Rev. source
Not checked in the free run.
- Findingown data
The body of evidence for ankle reliability is moderate (three studies, 52 participants, one HQ and two MQ studies).
“The body of evidence for the ankle is considered to be moderate (three studies, total of 52 participants [12 to 26 participants/study], one HQ and two MQ study).”
Quote in the paperNot a substantial claim - Findingcitation
Studies reporting the worst validity assessed sporting tasks or activities of daily living such as sweeping a table.
“For example, studies reporting the worst validity assessed sporting tasks or activities of daily living such as sweeping a table [32,34].”
Quote in the paperNot a substantial claim0 of 2 sources checked- cites [32] Fantozzi, 2016, Assessment of three-dimensional joint kinematics of the upper limb during simulated swimming using wearable inertial-magnetic measurement units, J. Sports Sci. source
Not checked in the free run.
- cites [34] Godwin, 2009, Accuracy of inertial motion sensors in static, quasistatic, and complex dynamic motion, J. Biomech. Eng. source
Not checked in the free run.
- Findingcitation
Ankle intra- and inter-rater reliability varied across movement complexity (better for walking ICC 0.6 to 0.95 than jumping ICC 0.39 to 0.99 or playing soccer ICC 0.28 to 0.79).
“Intra- and inter-rater reliability varied across movements complexity (better for walking [ICC of 0.6 to 0.95] than jumping [ICC of 0.39 to 0.99] or playing soccer [ICC of 0.28 to 0.79] [29,53,62]).”
Quote in the paperNot a substantial claim0 of 3 sources checked- cites [29] Akins, 2015, Reliability and validity of instrumented soccer equipment, J. Appl. Biomech. source
Not checked in the free run.
- cites [53] Al-Amri, M., Nicholas, K., Button, K., Sparkes, V., Sheeran, L., and Davies, J.L. (2018). Inertial Measurement Units for Clinical Movement Analysis: Reliability and Concurrent Validity. Sensors, 18. source
Not checked in the free run.
- cites [62] Mifsud, 2014, Portable Inertial Motion Unit for Continuous Assessment of In-shoe Foot Movement, Procedia Eng. source
Not checked in the free run.
- Findingreasoning
Evidence related to the validity of shoulder, elbow, and wrist movements was considered conflicting, particularly when participants were involved in complex movements or when the joint rotation around the Y axis was targeted.
“We considered evidence related to the validity of shoulder, elbow, and wrist movements to be conflicting, particularly when participants were involved in complex movements or when the joint rotation around the Y axis was targeted.”
Quote in the paperSubstantial claim - Findingnone given
Reliability is better for movements in the sagittal and frontal planes than in the transverse plane.
“As mentioned above for validity, reliability is better for movements in the sagittal and frontal planes than in the transverse plane.”
Quote in the paperNot a substantial claim - Findingnone given
Most of the included studies only assessed reliability during simple planar movements and locomotor tasks.
“However, most of the included studies only assessed reliability during simple planar movements and locomotor tasks.”
Quote in the paperSubstantial claim - Findingnone given
The different types of M/IMU gave similar reliability results (e.g., Xsens, Cuela, and Gait-up Physilog) regardless of the joint studied.
“The different types of M/IMU gave similar reliability results (e.g., Xsens, Cuela, and Gait-up Physilog) regardless of the joint studied.”
Quote in the paperNot a substantial claim - Findingreasoning
The overall quality of all articles was reduced by the small sample sizes.
“The overall quality of all articles was reduced by the small sample sizes (see above).”
Quote in the paperSubstantial claim - Findingown data
The small number of studies for each joint did not allow strong conclusions about reliability.
“Regarding reliability, the small number of studies for each joint did not allow us to make strong conclusions.”
Quote in the paperSubstantial claim - Findingnone given
The lack of standardization in protocols, such as the use of different biomechanical models for the same joint or different calibration procedures and sensor placements, makes it impossible to identify the main contributing factor to measurement errors.
“In addition, the lack of standardization in protocols such as the use of different biomechanical models for the same joint or of different calibration procedures and sensor placements makes it impossible to identify the main contributing factor to measurement errors.”
Quote in the paperSubstantial claim - Findingnone given
The sample size used in included studies ranged from one to 38 participants.
“The sample size used in included studies ranged from one to 38 participants.”
Quote in the paperSubstantial claim - Findingreasoning
M/IMUs provide real-time data in functional tasks within the same error range as inclinometers and goniometers (M/IMU: 0.7 to 15°; inclinometer and goniometer: 0.21 to 18°) for lower limb, trunk, wrist, and elbow joints.
“In clinical settings, M/IMUs should be considered as an alternative tool to inclinometers and goniometers, as they provide real-time data in functional tasks within the same error range as these more classical measurement devices (M/IMU: 0.7 to 15°; inclinometer and goniometer: 0.21 to 18°) for lower limb, trunk, wrist, and elbow joints.”
Quote in the paperSubstantial claim - Premisecitation
Combining accelerometer, gyroscope, and magnetometer signals through data fusion algorithms can provide a reliable estimate of M/IMU orientation.
“By combining the signals of each sensor through intelligent data fusion algorithms, one can obtain a reliable estimate of M/IMU orientation.”
- Also stated in: § 1. Introduction · plain
“Therefore, complimentary data are obtained when all three signals are captured [9].”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [9] Sabatini, 2011, Estimating Three-Dimensional Orientation of Human Body Parts by Inertial/Magnetic Sensing, Sensors source
Not checked in the free run.
- Also stated in: § 1. Introduction · plain
- Premisecitation
Two systematic reviews have been conducted on the psychometric evidence relating to M/IMU validity.
“Two systematic reviews have been conducted to report on the psychometric evidence relating to M/IMU validity [11,12].”
Quote in the paperSubstantial claim0 of 2 sources checked- cites [11] Walmsley, 2018, Measurement of Upper Limb Range of Motion Using Wearable Sensors: A Systematic Review, Sports Med. Open source
Not checked in the free run.
- cites [12] Williams, 2010, The use of inertial sensors system for human motion analysis, Phys. Ther. Rev. source
Not checked in the free run.
- Premisecitation
Kinematic data from accelerometers lack precision because they are affected by increased segment acceleration or drifts.
“However, kinematic data have been shown to lack precision since they are affected by increased segment acceleration or the presence of drifts (algorithms have been developed to decrease the effect of drifting in accelerometers) [4,5,6].”
Quote in the paperSubstantial claim0 of 3 sources checked- cites [4] Grimaldi, 2010, Neurological tremor: Sensors, signal processing and emerging applications, Sensors source
Not checked in the free run.
- cites [5] Dejnabadi, 2006, Estimation and visualization of sagittal kinematics of lower limbs orientation using body-fixed sensors, IEEE Trans. Biomed. Eng. source
Not checked in the free run.
- cites [6] Dejnabadi, 2005, A new approach to accurate measurement of uniaxial joint angles based on a combination of accelerometers and gyroscopes, IEEE Trans. Biomed. Eng. source
Not checked in the free run.
- Study design and conductown data
Pre-consensus inter-rater agreement between reviewers for total scores of the COSMIN grid and MacDermid's critical appraisal tool was excellent (Gwet = 0.85 to 0.96 and ICC = 0.93).
“The pre-consensus inter-rater agreement between reviewers for total scores of the COSMIN grid and MacDermid’s critical appraisal tool was considered excellent (Gwet = 0.85 to 0.96 and ICC = 0.93).”
Quote in the paperNot a substantial claim - Study design and conductreasoning
Due to heterogeneity of protocols and data acquisition systems, results could not be pooled in a meta-analysis.
“Due to the heterogeneity of protocols and data acquisition systems used in the selected articles, results of this systematic review could not be pooled in a meta-analysis.”
Quote in the paperSubstantial claim - Interpretationreasoning
M/IMU can be considered a valid tool to assess whole body range of motion.
“M/IMU should be considered as a valid tool to assess whole body range of motion, but further studies are needed to standardize technical procedures to obtain more accurate data.”
Quote in the paperSubstantial claim- Rests on an assumption: Findings from different M/IMU systems can be generalized to M/IMU as a class.
- Interpretationcitation
The increasing number of studies in recent years that used complex movements to assess M/IMU validity and the focus on the upper limb joint partially explain the different conclusions between the two previous systematic reviews and the present work.
“The increasing number of studies in recent years that used complex movements to assess M/IMU validity and the focus made on the upper limb joint partially explain the different conclusions between these two systematic reviews and the present work [12].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [12] Williams, 2010, The use of inertial sensors system for human motion analysis, Phys. Ther. Rev. source
Not checked in the free run.
- Interpretationnone given
M/IMUs appear to provide a suitable alternative to motion-capture systems, especially for flexion/extension movements at the lower limb joints during simple movements.
“Regarding validity, M/IMUs appear to provide a suitable alternative to motion-capture systems especially for flexion/extension movements at the lower limb joints during simple movements.”
Quote in the paperSubstantial claim - Premisecitation
Errors reported for camera-based motion capture systems varied across movement planes and joints, similar to M/IMUs.
“Interestingly, and similar to M/IMUs, errors reported for camera-based motion capture systems varied across movement planes and joints.”
Quote in the paperSubstantial claim0 of 2 sources checked- cites [46] Bauer, 2015, Concurrent validity and reliability of a novel wireless inertial measurement system to assess trunk movement, J. Electromyogr. Kinesiol. source
Not checked in the free run.
- cites [54] Bergmann, 2009, A portable system for collecting anatomical joint angles during stair ascent: A comparison with an optical tracking device, Dyn. Med. DM source
Not checked in the free run.
- Interpretationcitation
The greater variability added by biomechanical models for the upper limbs partly explains the large variability observed at the shoulder joint (RMSE as high as 40° in some articles).
“This partly explains the large variability observed at the shoulder joint (RMSE as high as 40° in some articles).”
Quote in the paperSubstantial claim - Premisecitation
Several studies have questioned the validity and accuracy of camera-based motion capture systems for certain joints and for complex movements.
“It is important to note here that, recently, several studies have questioned the validity and accuracy of camera-based motion capture systems for certain joints and for complex movements [46,54].”
Quote in the paperSubstantial claim0 of 2 sources checked- cites [46] Bauer, 2015, Concurrent validity and reliability of a novel wireless inertial measurement system to assess trunk movement, J. Electromyogr. Kinesiol. source
Not checked in the free run.
- cites [54] Bergmann, 2009, A portable system for collecting anatomical joint angles during stair ascent: A comparison with an optical tracking device, Dyn. Med. DM source
Not checked in the free run.
- Premisecitation
Biomechanical models used for the upper limbs are more likely to add variability, leading to larger RMSE.
“Their results showed that biomechanical models used for the upper limbs are more likely to add variability, leading to larger RMSE.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [37] Robert-Lachaine, X., Mecheri, H., Larue, C., and Plamondon, A. (2016). Validation of inertial measurement units with an optoelectronic system for whole-body motion analysis. Med. Biol. Eng. Comput. source
Not checked in the free run.
- Premisecitation
The choice of the biomechanical model used to convert M/IMU orientation data into anatomically meaningful information influences validity differently depending on the joint studied.
“Also, as demonstrated by Robert-Lachaine et al. [37], the choice of the biomechanical model used to convert M/IMU orientation data into anatomically meaningful information will also influence validity differently depending on the joint studied.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [37] Robert-Lachaine, X., Mecheri, H., Larue, C., and Plamondon, A. (2016). Validation of inertial measurement units with an optoelectronic system for whole-body motion analysis. Med. Biol. Eng. Comput. source
Not checked in the free run.
- Premisecitation
Errors ranging from 5 to 10° when compared to goniometer, inclinometer, and radiostereometric measurements have been evidenced for camera-based motion capture systems, the same error range as M/IMU systems.
“Indeed, errors ranging from 5 to 10° when compared to goniometer, inclinometer, and radiostereometric measurements have been evidenced (same error range as M/IMU systems).”
Quote in the paperSubstantial claim0 of 2 sources checked- cites [46] Bauer, 2015, Concurrent validity and reliability of a novel wireless inertial measurement system to assess trunk movement, J. Electromyogr. Kinesiol. source
Not checked in the free run.
- cites [54] Bergmann, 2009, A portable system for collecting anatomical joint angles during stair ascent: A comparison with an optical tracking device, Dyn. Med. DM source
Not checked in the free run.
- Interpretationreasoning
Functional upper limb tasks often require performing complex movements around two or three axes (X, Y, Z), which can account for the variability of results.
“Functional upper limb tasks often require performing complex movements around two or three axes (X, Y, Z), which can account for the variability of results.”
Quote in the paperSubstantial claim - Premiseown data
The sample size used in included studies is below the recommended sample size for this type of study (50 participants).
“This is below the recommended sample size for this type of study (50 participants).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [21] Terwee, 2007, Quality criteria were proposed for measurement properties of health status questionnaires, J. Clin. Epidemiol. source
Not checked in the free run.
- Interpretationreasoning
The validity and reliability results cannot be considered as directly representing M/IMU performance during real-life/outside of laboratory use.
“Therefore, they cannot be considered as directly representing M/IMU performance during real-life/outside of laboratory use.”
Quote in the paperSubstantial claim - Interpretationcitation
Sample sizes below the recommended 50 participants could lead to misinterpretation.
“This could lead to misinterpretation [21].”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [21] Terwee, 2007, Quality criteria were proposed for measurement properties of health status questionnaires, J. Clin. Epidemiol. source
Not checked in the free run.
- Interpretationreasoning
M/IMUs are an appropriate alternative to motion-capture based systems to study human movement.
“In conclusion, results from this systematic review suggest that M/IMUs are an appropriate alternative to motion-capture based systems to study human movement.”
Quote in the paperSubstantial claim
- May combine two claims. 72
- Classified as probably not a substantial claim. 23
May combine two claims.
Findingnone givenReported validity varied according to the joint evaluated, with better validity for lower limb joints.
“Reported validity varied according to task complexity (higher validity for simple tasks) and the joint evaluated (better validity for lower limb joints).”
Quote in the paperSubstantial claimMay combine two claims.
Findingown dataThirty-nine articles addressed M/IMU validity and fifteen reported on reliability.
“Thirty-nine articles addressed M/IMU validity and fifteen reported on reliability.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
Findingown dataForty-two studies were included in the review.
“Forty-two studies were included.”
- Also stated in: § 3. Results · plain
“forty-two articles were included”
Quote in the paperNot a substantial claim- Also stated in: § 3. Results · plain
May combine two claims.
Findingown dataAll fifteen reliability studies evaluated intra-rater reliability, with four also assessing inter-rater reliability.
“All of the fifteen studies assessing reliability evaluated intra-rater reliability, with four also assessing inter-rater reliability.”
Quote in the paperNot a substantial claimMay combine two claims.
FindingcitationNeck RMSE results varied between less than 1° and 9°, showing good joint measurement validity.
“RMSE results varied between less than 1° and 9°, showing good joint measurement validity [33,34,37,40,41].”
Quote in the paperSubstantial claim0 of 3 sources checked- cites [33] Pons, 2013, A novel motion tracking system for evaluation of functional rehabilitation of the upper limbs, Neural Regen. Res.
Not checked in the free run.
- cites [34] Godwin, 2009, Accuracy of inertial motion sensors in static, quasistatic, and complex dynamic motion, J. Biomech. Eng. source
Not checked in the free run.
- cites [37] Robert-Lachaine, X., Mecheri, H., Larue, C., and Plamondon, A. (2016). Validation of inertial measurement units with an optoelectronic system for whole-body motion analysis. Med. Biol. Eng. Comput. source
Not checked in the free run.
May combine two claims.
Findingown dataShoulder variability increased with movement complexity, with simple movement protocols showing better concordance (RMSE 1-21° simple, 5-64.5° complex).
“Variability increased with movement complexity, with simple movement protocols showing better concordance between studies (RMSE ranging from 1 to 21° for simple movements and from 5 to 64.5° for complex movements).”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
Findingown dataAcross the 42 studies, the majority focused on complex movements (n = 25) compared to simple movements (n = 17).
“Across the 42 studies, the majority focused on complex movements (n = 25) as compared to simple movements (n = 17).”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataSeven articles were classified as HQ, seven as MQ, twenty-four as LQ, and one as VLQ for criterion validity.
“Seven articles were classified as HQ studies, seven as MQ, twenty-four as LQ, and one as VLQ for criterion validity.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
Findingown dataAmong studies on complex movements, walking/running was the most frequently investigated (17/25).
“Among the studies on complex movements, walking/running was the most frequently investigated (17/25), other movements including kicking, throwing, swimming, and sweeping a table.”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataSix studies were categorized as HQ, six as MQ, and three as LQ for reliability (combined box B and C).
“Six studies were categorized as HQ, six as MQ, and three as LQ for reliability (combined box B and C).”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataCOSMIN box B (reliability) scores ranged from 22 to 100% with a mean of 67.4 ± 23.1%.
“Scores for box B (reliability) ranged from 22 to 100% with a mean of 67.4 ± 23.1%.”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataThe body of evidence for the neck joint is moderate (five studies, 44 participants, one HQ study).
“The body of evidence for the neck joint is considered as moderate (five studies, total of 44 participants [one to 20 participants/study], only one HQ study).”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataMacDermid critical appraisal scores ranged from 41 to 92% with a mean of 64.5 ± 12.9%.
“The scores on the MacDermid critical appraisal tool ranged from 41 to 92% (see Table S4) with a mean of 64.5 ± 12.9%.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
Findingown dataA total of 556 subjects were tested in the included studies (508 for validity and 184 for reliability).
“A total of 556 subjects were tested in the included studies (508 for validity and 184 for reliability).”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
Findingown dataThe Xsens was the most studied M/IMU system (15 articles), while other systems were investigated in three or less articles.
“The Xsens was the most studied M/IMU system (15 articles) while other systems were investigated in three or less articles (e.g., Cuela or Physilog).”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataThe majority of studies failed to score for sample size and detailed inclusion/exclusion criteria, partly explaining low-quality scores.
“The majority of studies failed to score for sample size and for detailed inclusion/exclusion criteria, thereby partly explaining the low-quality score for both grids.”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataCOSMIN box C (measurement error) scores ranged from 50 to 100% with a mean of 71.9 ± 12.8%.
“Scores for box C (measurement error) ranged from 50 to 100% with a mean of 71.9 ± 12.8%.”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataEleven articles were classified as HQ, twenty-two as MQ, and nine as LQ on the MacDermid tool.
“Eleven articles were classified as HQ studies, twenty-two as MQ, and nine as LQ.”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataCOSMIN box H scores ranged from 17 to 100% with a mean of 56.4 ± 20.1%.
“Scores for box H ranged from 17 to 100% with a mean of 56.4 ± 20.1%.”
Quote in the paperNot a substantial claimMay combine two claims.
FindingreasoningTrunk RMSE and correlation coefficients varied from 1.8 to 5.9° and 0.72 to 0.99 when excluding two poorest-quality studies, showing good to excellent validity.
“RMSE and correlation coefficients varied respectively from 1.8 to 5.9° and from 0.72 to 0.99 when excluding data from these two articles, showing good to excellent validity.”
Quote in the paperSubstantial claimMay combine two claims.
FindingcitationWrist RMSE and correlation coefficients varied from 2.2 to 30° and 0.62 to 0.99, showing fair to good validity.
“RMSE and correlation coefficients varied respectively from 2.2 to 30° and from 0.62 to 0.99, showing fair to good validity [28,32,33,35,37,43].”
Quote in the paperSubstantial claim0 of 3 sources checked- cites [28] Bouvier, 2015, Upper Limb Kinematics Using Inertial and Magnetic Sensors: Comparison of Sensor-to-Segment Calibrations, Sensors source
Not checked in the free run.
- cites [32] Fantozzi, 2016, Assessment of three-dimensional joint kinematics of the upper limb during simulated swimming using wearable inertial-magnetic measurement units, J. Sports Sci. source
Not checked in the free run.
- cites [33] Pons, 2013, A novel motion tracking system for evaluation of functional rehabilitation of the upper limbs, Neural Regen. Res.
Not checked in the free run.
May combine two claims.
Findingown dataThe body of evidence for the pelvis joint is strong (6 studies, 95 participants, three HQ studies).
“The body of evidence for the pelvis joint (tilt or obliquity) is considered to be strong (6 studies, total of 95 participants [six to 30 Participants/Study], three HQ studies).”
Quote in the paperSubstantial claimMay combine two claims.
Findingown dataThe body of evidence for the trunk is strong (11 studies, 167 participants, four HQ studies).
“The body of evidence for the trunk is considered to be strong (11 studies for the lumbar and thoracic spine, total of 167 participants [one to 38 participants/study], four HQ studies).”
Quote in the paperSubstantial claimMay combine two claims.
Findingown dataThe body of evidence for the hip joint is strong (13 studies, 195 participants, two HQ and eight MQ studies).
“The body of evidence for the hip joint is characterized as strong (13 studies, total of 195 participants [three to 30 participants/study], two HQ studies and eight MQ studies with similar results).”
Quote in the paperSubstantial claimMay combine two claims.
FindingcitationHip RMSE and correlation coefficients varied from 0.2 to 9.3° and 0.53 to 1.00, showing fair to excellent validity.
“RMSE and correlation coefficients varied respectively from 0.2 to 9.3° and 0.53 to 1.00, showing fair to excellent validity [5,30,37,41,42,46,53,54,55,56,57,58,59].”
Quote in the paperSubstantial claim0 of 3 sources checked- cites [5] Dejnabadi, 2006, Estimation and visualization of sagittal kinematics of lower limbs orientation using body-fixed sensors, IEEE Trans. Biomed. Eng. source
Not checked in the free run.
- cites [30] Blair, S., Duthie, G., Robertson, S., Hopkins, W., and Ball, K. (2018). Concurrent validation of an inertial measurement system to quantify kicking biomechanics in four football codes. J. Biomech. source
Not checked in the free run.
- cites [37] Robert-Lachaine, X., Mecheri, H., Larue, C., and Plamondon, A. (2016). Validation of inertial measurement units with an optoelectronic system for whole-body motion analysis. Med. Biol. Eng. Comput. source
Not checked in the free run.
May combine two claims.
Findingown dataHip rotation and transverse plane movements showed higher RMSE and lower correlations.
“Hip rotation and movements performed in the transverse plane (Y axis) showed higher RMSE and lower correlations (RMSE as high as 11.8° and r as low as 0.35).”
Quote in the paperNot a substantial claimMay combine two claims.
FindingcitationPelvis RMSE and correlation coefficients varied from 0.4 to 8.8° and 0.84 to 1.00, showing good to excellent validity.
“RMSE and correlation coefficients varied respectively from 0.4 to 8.8° and 0.84 to 1.00, showing good to excellent validity [30,36,38,41,42,52].”
Quote in the paperSubstantial claim0 of 3 sources checked- cites [30] Blair, S., Duthie, G., Robertson, S., Hopkins, W., and Ball, K. (2018). Concurrent validation of an inertial measurement system to quantify kicking biomechanics in four football codes. J. Biomech. source
Not checked in the free run.
- cites [36] Plamondon, 2007, Evaluation of a hybrid system for three-dimensional measurement of trunk posture in motion, Appl. Ergon. source
Not checked in the free run.
- cites [38] Schall, 2016, Accuracy and repeatability of an inertial measurement unit system for field-based occupational studies, Ergonomics source
Not checked in the free run.
May combine two claims.
FindingcitationElbow RMSE and correlation coefficient results ranged from 0.2 to 30.6° and 0.68 to 0.99, showing good to excellent validity.
“RMSE and correlation coefficient results range from 0.2 to 30.6° and 0.68 to 0.99, respectively, showing good to excellent validity [28,31,32,33,34,35,37,39,43,45].”
Quote in the paperSubstantial claim0 of 3 sources checked- cites [28] Bouvier, 2015, Upper Limb Kinematics Using Inertial and Magnetic Sensors: Comparison of Sensor-to-Segment Calibrations, Sensors source
Not checked in the free run.
- cites [31] Ertzgaard, 2016, A new way of assessing arm function in activity using kinematic Exposure Variation Analysis and portable inertial sensors—A validity study, Man. Ther. source
Not checked in the free run.
- cites [32] Fantozzi, 2016, Assessment of three-dimensional joint kinematics of the upper limb during simulated swimming using wearable inertial-magnetic measurement units, J. Sports Sci. source
Not checked in the free run.
May combine two claims.
Findingown dataThe body of evidence for the knee joint is strong (15 studies, 228 participants, three HQ and nine MQ studies).
“The body of evidence for the knee joint is considered to be strong (15 studies, total of 228 participants [three to 38 participants/study], three HQ and nine MQ studies).”
Quote in the paperNot a substantial claimMay combine two claims.
FindingcitationKnee RMSE and correlation varied from 1 to 11.5° and 0.4 to 1.00.
“RMSE and coefficient correlation varied respectively from 1 to 11.5° and 0.4 to 1.00 [5,30,37,41,43,48,50,53,54,55,57,58,59,60,61].”
Quote in the paperSubstantial claim0 of 3 sources checked- cites [5] Dejnabadi, 2006, Estimation and visualization of sagittal kinematics of lower limbs orientation using body-fixed sensors, IEEE Trans. Biomed. Eng. source
Not checked in the free run.
- cites [30] Blair, S., Duthie, G., Robertson, S., Hopkins, W., and Ball, K. (2018). Concurrent validation of an inertial measurement system to quantify kicking biomechanics in four football codes. J. Biomech. source
Not checked in the free run.
- cites [37] Robert-Lachaine, X., Mecheri, H., Larue, C., and Plamondon, A. (2016). Validation of inertial measurement units with an optoelectronic system for whole-body motion analysis. Med. Biol. Eng. Comput. source
Not checked in the free run.
May combine two claims.
FindingcitationShoulder SEM and ICC for inter-rater reliability ranged from 4.2 to 7.8° and 0.71 to 0.99.
“SEM and ICC for inter-raterreliability ranged respectively from 4.2 to 7.8° and 0.71 to 0.99 [28,66].”
Quote in the paperNot a substantial claim0 of 2 sources checked- cites [28] Bouvier, 2015, Upper Limb Kinematics Using Inertial and Magnetic Sensors: Comparison of Sensor-to-Segment Calibrations, Sensors source
Not checked in the free run.
- cites [66] Schiefer, 2015, A technical support tool for joint range of motion determination in functional diagnostics—An inter-rater study, J. Occup. Med. Toxicol. source
Not checked in the free run.
May combine two claims.
Findingown dataNeck cervical rotation showed poorer ICC (<0.8), while flexion/extension and lateral flexion showed excellent reliability (ICC ≥0.8).
“Cervical rotation showed poorer ICC (two studies with ICC < 0.8), while flexion/extension and lateral flexion showed excellent reliability (ICC ≥ 0.8).”
Quote in the paperNot a substantial claimMay combine two claims.
FindingcitationFor elbow reliability, one study showed excellent reliability in every movement direction (CMC ≥0.9) and the other presented poor to good reliability (ICC = 0.2 to 0.77).
“One study showed excellent reliability in every movement direction (CMC ≥ 0.9) and the other presented poor to good reliability (ICC = 0.2 to 0.77) [28,66].”
Quote in the paperSubstantial claim0 of 2 sources checked- cites [28] Bouvier, 2015, Upper Limb Kinematics Using Inertial and Magnetic Sensors: Comparison of Sensor-to-Segment Calibrations, Sensors source
Not checked in the free run.
- cites [66] Schiefer, 2015, A technical support tool for joint range of motion determination in functional diagnostics—An inter-rater study, J. Occup. Med. Toxicol. source
Not checked in the free run.
May combine two claims.
FindingcitationAnkle RMSE and correlation coefficients varied from 0.4 to 18.8° and 0.33 to 0.99.
“RMSE and correlation coefficients varied respectively from 0.4 to 18.8° and 0.33 to 0.99 [29,37,41,43,53,54,55,57,59,62,63].”
Quote in the paperNot a substantial claim0 of 3 sources checked- cites [29] Akins, 2015, Reliability and validity of instrumented soccer equipment, J. Appl. Biomech. source
Not checked in the free run.
- cites [37] Robert-Lachaine, X., Mecheri, H., Larue, C., and Plamondon, A. (2016). Validation of inertial measurement units with an optoelectronic system for whole-body motion analysis. Med. Biol. Eng. Comput. source
Not checked in the free run.
- cites [41] Lebel, K., Boissy, P., Nguyen, H., and Duval, C. (2017). Inertial measurement systems for segments and joints kinematics assessment: Towards an understanding of the variations in sensors accuracy. BioMed. Eng. Online, 16. source
Not checked in the free run.
May combine two claims.
Findingown dataThe body of evidence for neck reliability is moderate (three studies, 48 participants, one HQ and two MQ studies).
“The body of evidence for the neck is considered to be moderate (three studies, total of 48 participants [10 to 20 participants/study], one HQ study and two MQ).”
Quote in the paperNot a substantial claimMay combine two claims.
FindingcitationNeck SEM and ICC for inter-rater reliability ranged from 1.2 to 9.4° and 0.64 to 0.99.
“Standard error of the mean (SEM) and ICC for inter-rater reliability ranged respectively from 1.2 to 9.4° and from 0.64 to 0.99 [64,65,66].”
Quote in the paperNot a substantial claim0 of 3 sources checked- cites [64] Duc, 2014, A wearable inertial system to assess the cervical spine mobility: Comparison with an optoelectronic-based motion capture evaluation, Med. Eng. Phys. source
Not checked in the free run.
- cites [65] Kim, H., Shin, S.-H., Kim, J.-K., Park, Y.-J., Oh, H.-S., and Park, Y.-B. (2013). Cervical Coupling Motion Characteristics in Healthy People Using a Wireless Inertial Measurement Unit. Evid.-Based Complement. Altern. Med., 2013. source
Not checked in the free run.
- cites [66] Schiefer, 2015, A technical support tool for joint range of motion determination in functional diagnostics—An inter-rater study, J. Occup. Med. Toxicol. source
Not checked in the free run.
May combine two claims.
FindingcitationScapula inter-rater reliability is fair to good for retraction-protraction and mediolateral rotation, but poor to fair for anterior-posterior tilt.
“Inter-rater reliability is considered as fair to good for scapular retraction–protraction and scapular mediolateral rotation (r = 0.59 to 0.91), but as poor to fair for anterior–posterior tilt (r = 0.32 to 0.87) [67].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [67] Wiertsema, 2014, Reliability and precision of 3D wireless measurement of scapular kinematics, Med. Biol. Eng. Comput. source
Not checked in the free run.
May combine two claims.
Findingown dataThe body of evidence for the ankle joint is strong (11 studies, 141 participants, three HQ and nine MQ studies).
“The body of evidence for the ankle joint is considered to be strong (11 studies, total of 141 participants [three to 26 participants/study], three HQ and nine MQ studies).”
Quote in the paperSubstantial claimMay combine two claims.
FindingreasoningThe body of evidence for elbow reliability is conflicting (two studies, 30 participants).
“The body of evidence for the elbow is considered to be conflicting as the two studies included presented inconsistent results (two studies, total of 30 participants [10 to 20 participants/study]).”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataThe body of evidence for shoulder reliability is limited (two studies, 30 participants, one HQ and one MQ study).
“The body of evidence for the shoulder is considered to be limited (two studies, total of 30 participants (10 to 20 participants/study], one HQ study and one MQ).”
Quote in the paperNot a substantial claimMay combine two claims.
FindingcitationKnee intra-rater reliability was fair to excellent and inter-rater reliability varied across movements (good for walking ICC 0.4 to 0.74 and poor for jumping ICC ≤0.39).
“Intra-rater reliability was fair to excellent and inter-rater reliability varied across movements performed (good for walking [ICC from 0.4 to 0.74] and poor for jumping [ICC ≤ 0.39] [45,53,59]).”
Quote in the paperNot a substantial claim0 of 3 sources checked- cites [45] Cutti, 2008, Ambulatory measurement of shoulder and elbow kinematics through inertial and magnetic sensors, Med. Biol. Eng. Comput. source
Not checked in the free run.
- cites [53] Al-Amri, M., Nicholas, K., Button, K., Sparkes, V., Sheeran, L., and Davies, J.L. (2018). Inertial Measurement Units for Clinical Movement Analysis: Reliability and Concurrent Validity. Sensors, 18. source
Not checked in the free run.
- cites [59] Zhang, 2013, Concurrent validation of Xsens MVN measurement of lower limb joint angular kinematics, Physiol. Meas. source
Not checked in the free run.
May combine two claims.
FindingcitationTrunk reliability results are consistent and demonstrate good to excellent intra-rater reliability (ICC ≥0.8 except coronal plane fair to excellent 0.67 to 0.93).
“Results from these three studies are consistent and demonstrate good to excellent intra-rater reliability (ICC ≥ 0.8 except for coronal plane which is fair to excellent (0.67 to 0.93)) [46,66,68].”
Quote in the paperNot a substantial claim0 of 3 sources checked- cites [46] Bauer, 2015, Concurrent validity and reliability of a novel wireless inertial measurement system to assess trunk movement, J. Electromyogr. Kinesiol. source
Not checked in the free run.
- cites [66] Schiefer, 2015, A technical support tool for joint range of motion determination in functional diagnostics—An inter-rater study, J. Occup. Med. Toxicol. source
Not checked in the free run.
- cites [68] Yun, 2015, Individual characteristics of reliable lumbar coupling motions, Eur. Spine J. source
Not checked in the free run.
May combine two claims.
Findingown dataThe body of evidence for trunk reliability is moderate (three studies, 63 participants, two HQ and one MQ study).
“The body of evidence for the trunk is considered to be moderate (three studies, total of 63 participants [19 to 24 participants/study], two HQ and one MQ study).”
Quote in the paperNot a substantial claimMay combine two claims.
FindingcitationHip intra-rater reliability is fair to excellent and inter-rater reliability varied across movements (good for walking ICC 0.4 to 0.74 and poor for jumping ICC ≤0.39).
“Intra-rater reliability is fair to excellent and inter-rater reliability varied across movements performed (good for walking [ICC of 0.4 to 0.74] and poor for jumping [ICC ≤ 0.39] [46,53,66]).”
Quote in the paperNot a substantial claim0 of 3 sources checked- cites [46] Bauer, 2015, Concurrent validity and reliability of a novel wireless inertial measurement system to assess trunk movement, J. Electromyogr. Kinesiol. source
Not checked in the free run.
- cites [53] Al-Amri, M., Nicholas, K., Button, K., Sparkes, V., Sheeran, L., and Davies, J.L. (2018). Inertial Measurement Units for Clinical Movement Analysis: Reliability and Concurrent Validity. Sensors, 18. source
Not checked in the free run.
- cites [66] Schiefer, 2015, A technical support tool for joint range of motion determination in functional diagnostics—An inter-rater study, J. Occup. Med. Toxicol. source
Not checked in the free run.
May combine two claims.
Findingown dataThe body of evidence for wrist reliability is limited (two studies, 30 participants, one HQ and one MQ study).
“The body of evidence for the wrist is considered to be limited (two studies, total of 30 participants [10 to 20 participants/study], one HQ study and one MQ).”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataThe body of evidence for knee reliability is moderate (three studies, 56 participants, one HQ and two MQ studies).
“The body of evidence for the knee is considered to be moderate (three studies, total of 56 participants [10 to 26 participants/study], one HQ and two MQ study).”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
Findingnone givenWalmsley et al.'s results for the upper limbs are in agreement with those presented in this review.
“Their results for the upper limbs are in agreement with those presented here.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [11] Walmsley, 2018, Measurement of Upper Limb Range of Motion Using Wearable Sensors: A Systematic Review, Sports Med. Open source
Not checked in the free run.
May combine two claims.
FindingreasoningIt was not possible in this systematic review to reach a conclusion on the best calibration procedure for a given movement/context, as many studies did not identify or sufficiently describe their calibration procedure.
“It was not possible in this systematic review to reach a conclusion on the best calibration procedure for a given movement/context, as many studies did not identify or sufficiently described their calibration procedure.”
Quote in the paperSubstantial claimMay combine two claims.
FindingreasoningLower limb and trunk movements are mostly performed in closed chains and in one plane of movement, providing more consistent results, except for movements with smaller ROM (e.g., knee abduction/adduction or ankle internal/external rotation).
“In contrast, lower limb and trunk movements are mostly performed in closed chains and in one plane of movement, providing more consistent results, except for movements with smaller ROM (e.g., knee abduction/adduction or ankle internal/external rotation).”
Quote in the paperSubstantial claimMay combine two claims.
Findingnone givenThe validity of motion capture and M/IMUs for trunk and lower limb joints is similar except for the rotation component, suggesting that M/IMUs could be a good alternative to motion capture systems for movement measurements in the sagittal and frontal planes, but not in the transverse plane.
“The validity of motion capture and M/IMUs for trunk and lower limb joints are similar except for the rotation component, suggesting that M/IMUs could be a good alternative to motion capture systems for movement measurements in the sagittal and frontal planes, but not in the transverse plane.”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S4 (based).
Findingnone givenThe complexity of the movement leads to more variability in abduction/adduction for the upper limbs.
“However, the complexity of the movement leads to more variability in abduction/adduction, which needs to be considered.”
Quote in the paperNot a substantial claimMay combine two claims.
Findingnone givenMost of the studies included in this review are of moderate to high quality, suggesting a low risk of bias in conclusions.
“Most of the studies included in this review are of moderate to high quality, suggesting a low risk of bias in conclusions.”
Quote in the paperSubstantial claimMay combine two claims.
FindingcitationThe absolute error reported for M/IMU ranged from 0.3° to 9.9°, which is better than the goniometer and inclinometer reliability (inclinometer: 1° to 32°; goniometer: 1° to 45°).
“Moreover, the absolute error reported for M/IMU ranged from 0.3° to 9.9° which is better than the goniometer and inclinometer reliability (inclinometer: 1° to 32°; goniometer: 1° to 45°) [69].”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [69] Roy, J.-S., Desmeules, F., Frémont, P., Dionne, C., and MacDermid, J. (2015). L’évaluation Clinique, les Traitements et le Retour en Emploi de Travailleurs Souffrant D’atteintes de la Coiffe des Rotateurs—Bilan des Connaissances, Institut de Recherche Robert-Sauvé en Santé et en Sécurité du Travail (IRSST). R-885.
Not checked in the free run.
May combine two claims.
FindingreasoningOnly two articles had a good score on the sample-size criterion, but based mainly on the fact that a justification was provided.
“Only two articles had a good score on this criterion, but based mainly on the fact that a justification was provided.”
Quote in the paperNot a substantial claimMay combine two claims.
Findingnone givenThe majority of included studies had the same limitations: small sample sizes without justification, targeting only one psychometric property, and lack of description of inclusion/exclusion criteria.
“However, the majority of studies had the same limitations: small sample sizes without justification, targeting only one psychometric property, and lack of description of inclusion/exclusion criteria.”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataDespite the high number of studies included in this review (42 articles), there are only twelve high-quality studies, which restricted conclusions.
“Furthermore, despite the high number of studies included in this review (42 articles), there are only twelve high quality studies, which restricted conclusions.”
Quote in the paperSubstantial claimMay combine two claims.
Findingnone givenThe factors of small sample sizes without justification, targeting only one psychometric property, and lack of description of inclusion/exclusion criteria lowered study quality but did not interfere with the precision of the reported data.
“These factors have lowered study quality but did not interfere with precision of the reported data.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S4 (based). May combine two claims.
Findingnone givenThe complexity of the movements assessed varied widely between studies, and M/IMU systems have lower validity in complex movements than in simple movements.
“The complexity of the movements assessed varied widely between studies and, as mentioned, M/IMU systems have lower validity in complex movements than in simple movements.”
Quote in the paperNot a substantial claimMay combine two claims.
Findingnone givenBecause a restricted number of articles have been conducted on M/IMU reliability, it is not possible to reach a conclusion on the best specific procedures (e.g., calibration) to ensure reliable data.
“However, as a restricted number of articles have been conducted on M/IMU reliability it is not possible to reach a conclusion on the best specific procedures (e.g., the calibration) to ensure reliable data.”
Quote in the paperSubstantial claimClassified as probably not a substantial claim. May combine two claims.
PremisecitationWearable sensors are wireless, small, and light, and have been suggested to overcome the lack of portability of laboratory systems.
“The use of wearable sensors has been suggested to overcome this lack of portability, as they are wireless, small, and light [3].”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [3] Godfrey, 2008, Direct measurement of human movement by accelerometry, Med. Eng. Phys. source
Not checked in the free run.
May combine two claims.
PremisecitationMotion capture systems are recognized as the gold standard for joint angle calculation and movement quantification.
“Motion capture systems are recognized as the gold standard for joint angle calculation.”
- Also stated in: § 1. Introduction · boosted
“commonly recognized as the gold standard for movement quantification [2]”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [2] Ceseracciu, E., Sawacha, Z., and Cobelli, C. (2014). Comparison of Markerless and Marker-Based Motion Capture Technologies through Simultaneous Data Collection during Gait: Proof of Concept. PLoS ONE, 9. source
Not checked in the free run.
- Also stated in: § 1. Introduction · boosted
May combine two claims.
PremisereasoningM/IMUs provide more accurate kinematic data than accelerometers alone while being wireless, robust, and portable.
“M/IMUs provide more accurate kinematic data than accelerometers alone, while still being wireless, robust, and portable.”
Quote in the paperSubstantial claimMay combine two claims.
PremisereasoningMotion capture systems can only be used in controlled laboratory environments due to lack of portability and required technical expertise, limiting their clinical applications.
“studies using these systems are restricted to laboratory settings for technical reasons, which may lead to findings that are not representative of real-life context”
- Also stated in: § 1. Introduction · plain
“However, these systems can only be used in controlled environments due to their lack of portability and to the technical expertise required, thereby limiting their potential clinical applications.”
Quote in the paperSubstantial claim- Also stated in: § 1. Introduction · plain
May combine two claims.
PremisecitationThe other systematic review published in 2018 focused only on the upper limb and provided scarce details regarding task complexity.
“The other systematic review, published in 2018, focused only on the upper limb and provided only scarce details regarding the complexity of the tasks evaluated, a problem highlighted by the first systematic review as being one of the most challenging aspects for clinical evaluation.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [12] Williams, 2010, The use of inertial sensors system for human motion analysis, Phys. Ther. Rev. source
Not checked in the free run.
Probably not a substantial claim: may not pass S3 (load-bearing).
Study design and conductcitationThe review followed PRISMA guidelines.
“This systematic review follows the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines [13]”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [13] Moher, 2009, Preferred reporting items for systematic reviews and meta-analyses: The PRISMA statement, BMJ source
Not checked in the free run.
Classified as probably not a substantial claim.
Study design and conductnone givenThe two quality assessment grids taken together allow a complete assessment of overall article quality.
“These two grids taken together allow a complete assessment of the overall article quality.”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S2 (checkable).
InterpretationreasoningThere is a need for a synthesis and an update for whole body kinematics.
“This highlights the need for a synthesis and an update for whole body kinematics.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
Study design and conductown dataTitles and abstracts were screened independently by two reviewers, with discrepancies resolved by consensus and a third reviewer available if needed.
“Titles and abstracts of the identified papers were screened independently by two reviewers (IP: Isabelle Poitras and FD: Frédérique Dupuis) to identify eligible articles.”
- Also stated in: § 2.2. Data Sources · plain
“Any discrepancy was resolved during a consensus meeting, and a third reviewer (JSR: Jean-Sébastien Roy) was available if needed but turned out not to be required.”
Quote in the paperNot a substantial claim- Also stated in: § 2.2. Data Sources · plain
May combine two claims.
PremisecitationThe first systematic review published in 2010 concluded that M/IMUs could be a valid tool to measure range of motion, but results were variable across joints and tasks.
“The first systematic review published in 2010 concluded that M/IMUs could be a valid tool to measure range of motion, but results were variable across joints and tasks performed [8].”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [8] Kok, 2016, Magnetometer Calibration Using Inertial Sensors, IEEE Sens. J. source
Not checked in the free run.
Classified as probably not a substantial claim. May combine two claims.
Study design and conductown dataAll included articles were independently critically appraised by two reviewers using COSMIN and MacDermid tools.
“All included articles were independently critically appraised by two reviewers (IP and FD) using two different quality assessment tools: consensus-based standards for the selection of health measurement instruments (COSMIN) [21] and the critical appraisal tool by MacDermid (2008) [22].”
Quote in the paperSubstantial claim0 of 2 sources checked- cites [21] Terwee, 2007, Quality criteria were proposed for measurement properties of health status questionnaires, J. Clin. Epidemiol. source
Not checked in the free run.
- cites [22] MacDermid, J.C. (2008). Critical appraisal of study design for psychometric articles evaluation form and interpretation guide. Evidence Based Rehabilitation: A Guide to Practice, Slack. [3rd ed.].
Not checked in the free run.
Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
Study design and conductnone givenEach of two reviewers performed complete data extraction of half of the included articles, and the extraction was corroborated or completed by the other reviewer.
“Each of the two reviewers performed a complete data extraction of half of the included articles and the extraction was corroborated or completed by the other reviewer.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
Study design and conductnone givenThe review was prospectively registered with PROSPERO in August 2018 (CRD42018104775).
“was prospectively registered with the International Prospective Register of Systematic Reviews (PROSPERO) in August 2018 (CRD42018104775).”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationEcological tasks related to activities of daily living generally require complex movements, the use of both upper and lower limb joints, movements in more than one plane, and irregular movement speed, which all drastically affect M/IMU system performance.
“Indeed, ecological tasks related to activities of daily living generally require complex movements, the use of both upper and lower limb joints, movements in more than one plane, and irregular movement speed, which all drastically affect system performance (e.g., walking at different speed vs. running [62,63]).”
Quote in the paperSubstantial claim0 of 2 sources checked- cites [62] Mifsud, 2014, Portable Inertial Motion Unit for Continuous Assessment of In-shoe Foot Movement, Procedia Eng. source
Not checked in the free run.
- cites [63] Rouhani, H., Favre, J., Crevoisier, X., and Aminian, K. (2012). Measurement of multi-segment foot joint angles during gait using a wearable system. J. Biomech. Eng., 134. source
Not checked in the free run.
May combine two claims.
PremisecitationProper calibration (proper alignment of the M/IMU axes with the anatomical segment axes) is an important factor contributing to better reliability, as different calibration protocols may result in substantially different results.
“Proper calibration (proper alignment of the M/IMU axes with the anatomical segment axes) is another important factor contributing to better reliability, as different calibration protocols may result in substantially different results [28].”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [28] Bouvier, 2015, Upper Limb Kinematics Using Inertial and Magnetic Sensors: Comparison of Sensor-to-Segment Calibrations, Sensors source
Not checked in the free run.
May combine two claims.
InterpretationreasoningA poor calibration in which sensors are not aligned with the body segment could interfere with data quality, because the initial calibration is the reference to calculate joint angulation during body movement.
“As the initial calibration is the reference to calculate joint angulation during body movement, a poor calibration in which sensors are not aligned with the body segment could interfere with data quality.”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S4 (based).
Interpretationnone givenFor the upper limbs, flexion/extension movements should be considered valid in every context.
“For the upper limbs, flexion/extension movements should be considered valid in every context.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationThe weaknesses of each sensor in the estimation of joint kinematics could have separately impacted the accuracy/reliability of M/IMUs, as sensor fusion does not fully compensate for all sensor limitations.
“Another important aspect to consider, as discussed in the Materials and Methods section, is that the weaknesses of each sensor in the estimation of joint kinematics could have separately impacted the accuracy/reliability of M/IMUs as sensor fusion does not fully compensate for all sensors limitations [9].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [9] Sabatini, 2011, Estimating Three-Dimensional Orientation of Human Body Parts by Inertial/Magnetic Sensing, Sensors source
Not checked in the free run.
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationShoulder rotation is more influenced by the biomechanical model than shoulder flexion-extension or abduction/adduction.
“According to Robert-Lachaine et al., shoulder rotation is also more influenced by the biomechanical model than shoulder flexion–extension or abduction/adduction.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [37] Robert-Lachaine, X., Mecheri, H., Larue, C., and Plamondon, A. (2016). Validation of inertial measurement units with an optoelectronic system for whole-body motion analysis. Med. Biol. Eng. Comput. source
Not checked in the free run.
Classified as probably not a substantial claim. May combine two claims.
InterpretationreasoningSpecial considerations will be needed in pathological populations because most calibration procedures require specific posture or movement, which could be challenging for some populations (e.g., cerebral palsy).
“However, special considerations will be needed in pathological populations as most of the calibration procedures require specific posture or movement, which could be challenging for some populations (e.g., cerebral palsy).”
Quote in the paperSubstantial claimMay combine two claims.
Study design and conductreasoningThe validity and reliability results presented in this systematic review represent the use of M/IMU in controlled environments, as all included studies were performed in laboratory settings.
“Limitations of this research include that the validity and reliability results presented in this systematic review represented the use of M/IMU in controlled environments as all the included studies were performed in laboratory settings.”
Quote in the paperSubstantial claimMay combine two claims.
InterpretationreasoningM/IMUs provide valid data to assess range of motion and joint orientation, so rehabilitation research and health care services could benefit from them.
“Rehabilitation research and health care services could benefit from M/IMUs as they provide valid data to assess range of motion and joint orientation.”
Quote in the paperSubstantial claimClassified as probably not a substantial claim. May combine two claims.
InterpretationreasoningBecause validity has been demonstrated in a majority of body joints for healthy subjects, it is possible to assess psychometric properties in pathological populations.
“As the validity has been demonstrated in a majority of body joints for healthy subjects, it opens the possibility to assess psychometric properties in pathological populations.”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S2 (checkable), S3 (load-bearing), S4 (based).
InterpretationreasoningMore complex movements would probably show less reliable results.
“Here also, more complex movements would probably show less reliable results.”
Quote in the paperNot a substantial claimMay combine two claims.
Study design and conductreasoningThe heterogeneity of movements studied across the 42 articles is an important risk of bias and did not allow us to perform quantitative analysis.
“Another important risk of bias is the heterogeneity of movements studied across the 42 articles, which did not allow us to perform quantitative analysis.”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S4 (based).
Interpretationnone givenThe main advantage of M/IMUs is that they can provide accurate data at a lower cost than a motion-capture system.
“The main advantage of M/IMUs is that they can provide accurate data at a lower cost than a motion-capture system.”
Quote in the paperNot a substantial claimClassified as probably not a substantial claim.
Study design and conductreasoningTo lower the risk of bias, we gave less impact to studies performed on only one participant.
“To lower this risk of bias, we gave less impact to studies performed on only one participant.”
Quote in the paperSubstantial claim
The paper relies on this without support.
Findings from different M/IMU systems can be generalized to M/IMU as a class.
“The Xsens was the most studied M/IMU system (15 articles) while other systems were investigated in three or less articles (e.g., Cuela or Physilog).”
“M/IMU should be considered as a valid tool to assess whole body range of motion, but further studies are needed to standardize technical procedures to obtain more accurate data.”
The paper relies on this without support.
The reference measures used in included studies (motion-capture systems or goniometers) provide valid criterion measurements for joint angles.
“compared M/IMUs to a gold standard (motion-capture system for lab systems or goniometer for clinical measures) for the measurement (accelerometer, gyroscope with or without magnetometer) of the range of motion data”
The paper relies on this without support.
Validity and reliability indices from studies using different protocols and data acquisition systems are comparable enough to be synthesized descriptively.
“Due to the heterogeneity of protocols and data acquisition systems used in the selected articles, results of this systematic review could not be pooled in a meta-analysis. For this reason, only a descriptive synthesis of results was performed.”
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Multiple sensors used to monitor various aspects of a target may be independent of each other, not designed to work together or provide a unified view of the system being monitored.
“Besides, multiple sensors are used to monitor various aspects of the target (Borchers and Pieler 2010; Dong et al. 2022). These sensors may be independent of each other (Poitras et al. 2019), meaning that they are not designed to work together or provide a unified view of the system being monitored.”
From Artificial intelligence enhanced sensors - enabling technologies to next-generation healthcare and biomedical platform (2023) · cites this paper as Poitras et al. 2019
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Hip results fall outside their stated ranges
MajorThe hip section first gives a maximum RMSE of 9.3° and a minimum correlation of 0.53, then reports hip-rotation results of 11.8° and 0.35.
“RMSE and correlation coefficients varied respectively from 0.2 to 9.3° and 0.53 to 1.00”
“Hip rotation and movements performed in the transverse plane (Y axis) showed higher RMSE and lower correlations (RMSE as high as 11.8° and r as low as 0.35).”
Walking ICCs called good are below the paper's good threshold
MinorThe hip reliability section calls walking ICCs of 0.4-0.74 good, although the paper defines values below 0.5 as poor and 0.5-0.75 as moderate. The knee reliability section repeats the same classification.
“good for walking [ICC of 0.4 to 0.74] and poor for jumping [ICC ≤ 0.39]”
“ICC, r, CMC, and r2 were considered as poor (<0.5), moderate (between 0.5 and 0.75), good (between 0.75 and 0.9), or excellent (>0.90) [17].”
Wrist errors exceed the stated maximum
MinorThe wrist section gives 30° as the maximum RMSE but subsequently describes results from one study as higher than 30°.
“RMSE and correlation coefficients varied respectively from 2.2 to 30° and from 0.62 to 0.99”
“one study using home-made sensors which presented poor results for all of the movements performed (RMSE higher than 30° and r as low as 0.62)”
Ankle study-quality counts exceed the number of studies
MinorThe ankle section reports 11 studies, but its three high-quality and nine moderate-quality studies total 12.
Reported 11 · recomputed 12
“The body of evidence for the ankle joint is considered to be strong (11 studies, total of 141 participants [three to 26 participants/study], three HQ and nine MQ studies).”
Ten articles are claimed but eleven are cited
MinorThe sentence says ten articles reported results for various complex movements, but its citation list contains eleven distinct articles.
“Ten articles reported results for various complex movements”
“[29,30,31,32,33,34,35,36,37,38,39].”
A single high-quality pelvis study is assigned the wrong evidence level
MinorThe stated evidence scale assigns one high-quality study to limited evidence, but the pelvis reliability section calls its evidence moderate on that basis.
“The body of evidence for the pelvis is considered to be moderate (one study, total of one participant, one HQ study).”
“Limited evidence: multiple MQ or LQ studies with inconsistent results, or one HQ.”
The cited 2010 systematic review is a 2016 magnetometer paper
MinorThe introduction cites reference 8 for a systematic review published in 2010, but reference 8 is a magnetometer-calibration paper published in 2016.
“The first systematic review published in 2010 concluded that M/IMUs could be a valid tool to measure range of motion, but results were variable across joints and tasks performed [8].”
“8. Kok M. Schon T.B. Magnetometer Calibration Using Inertial Sensors IEEE Sens. J. 2016 16 5679 5689 10.1109/JSEN.2016.2569160”
The number of high-quality articles changes
MinorThe methodological-quality results classify 11 articles as high quality, whereas the discussion says there are 12 high-quality studies.
“Eleven articles were classified as HQ studies, twenty-two as MQ, and nine as LQ.”
“despite the high number of studies included in this review (42 articles), there are only twelve high quality studies”
Cites
Preferred Reporting Items for Systematic Reviews and Meta-Analyses: the PRISMA statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & for the PRISMA Group (2009) · BMJ · doi:10.1136/bmj.b2535 · Cited by 83,823 · see citing works
Preferred reporting items for systematic reviews and meta-analyses: the PRISMA Statement.
(2009) · PubMed Central · Cited by 44,859 · see citing works
A guideline of selecting and reporting intraclass correlation coefficients for reliability research
Koo, T. K., & Li, M. Y. (2016) · Journal of Chiropractic Medicine · doi:10.1016/j.jcm.2016.02.012 · Cited by 29,639 · see citing works
Quality criteria were proposed for measurement properties of health status questionnaires
Terwee, C. B., Bot, S. D. M., de Boer, M. R., van der Windt, D. A. W. M., Knol, D. L., Dekker, J., Bouter, L. M., & de Vet, H. C. W. (2007) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2006.03.012 · Cited by 10,764 · see citing works
GRADE guidelines: 3. Rating the quality of evidence
Balshem, H., Helfand, M., Schünemann, H. J., Oxman, A. D., Kunz, R., Brozek, J., Vist, G. E., Falck-Ytter, Y., Meerpohl, J., & Norris, S. (2011) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2010.07.015 · Cited by 8,285 · see citing works
Updated Method Guidelines for Systematic Reviews in the Cochrane Collaboration Back Review Group
van Tulder, M., Furlan, A., Bombardier, C., & Bouter, L. (2003) · Spine · doi:10.1097/01.brs.0000065484.95996.af · Cited by 2,180 · see citing works
Direct measurement of human movement by accelerometry
Godfrey, A., Conway, R., Meagher, D., & ÓLaighin, G. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2008.09.005 · Cited by 591 · see citing works
A practical gait analysis system using gyroscopes
Tong, K., & Granat, M. H. (1999) · Medical Engineering & Physics · doi:10.1016/s1350-4533(99)00030-2 · Cited by 460 · see citing works
The use of inertial sensors system for human motion analysis
Cuesta-Vargas, A. I., Galán-Mercant, A., & Williams, J. M. (2010) · Physical Therapy Reviews · doi:10.1179/1743288x11y.0000000006 · Cited by 369 · see citing works
Inertial head-tracker sensor fusion by a complementary separate-bias Kalman filter
Foxlin, E. M. (1996) · doi:10.1109/vrais.1996.490527 · Cited by 366 · see citing works
Estimating Three-Dimensional Orientation of Human Body Parts by Inertial/Magnetic Sensing
Sabatini, A. M. (2011) · Sensors · doi:10.3390/s110201489 · Cited by 349 · see citing works
Robert-Lachaine, X., Mecheri, H., Larue, C., & Plamondon, A. (2017) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-016-1537-2 · Cited by 329 · see citing works
Accelerometry—A technique for the measurement of human body movements
Morris, J. R. W. (1973) · Journal of Biomechanics · doi:10.1016/0021-9290(73)90029-8 · Cited by 325 · see citing works
Inertial Measurement Units for Clinical Movement Analysis: Reliability and Concurrent Validity
Al-Amri, M., Nicholas, K., Button, K., Sparkes, V., Sheeran, L., & Davies, J. (2018) · Sensors · doi:10.3390/s18030719 · Cited by 318 · see citing works
Ambulatory measurement of 3D knee joint angle
Favre, J., Jolles, B. M., Aïssaoui, R., & Aminian, K. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.12.003 · Cited by 315 · see citing works
Concurrent validation of Xsens MVN measurement of lower limb joint angular kinematics
Zhang, J.-T., Novak, A. C., Brouwer, B., & Li, Q. (2013) · Physiological Measurement · doi:10.1088/0967-3334/34/8/n63 · Cited by 314 · see citing works
Ambulatory measurement of shoulder and elbow kinematics through inertial and magnetic sensors
Cutti, A. G., Giovanardi, A., Rocchi, L., Davalli, A., & Sacchetti, R. (2008) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-007-0296-5 · Cited by 311 · see citing works
Porciuncula, F., Cataldo, A. V. R., Kumar, D., Davis, I. S., Roy, S. H., Walsh, C. J., & Awad, L. N. (2018) · PM&R · doi:10.1016/j.pmrj.2018.06.013 · Cited by 304 · see citing works
Fong, D. T.-P., & Chan, Y.-Y. (2010) · Sensors · doi:10.3390/s101211556 · Cited by 287 · see citing works
Dejnabadi, H., Jolles, B. M., & Aminian, K. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.851475 · Cited by 286 · see citing works
Picerno, P. (2017) · Gait & Posture · doi:10.1016/j.gaitpost.2016.11.008 · Cited by 237 · see citing works
Ceseracciu, E., Sawacha, Z., & Cobelli, C. (2014) · PLoS ONE · doi:10.1371/journal.pone.0087640 · Cited by 210 · see citing works
Gait posture estimation using wearable acceleration and gyro sensors
Takeda, R., TADANO, S., Akiko Natorigawa, A., Masahiro Todoh, A., & Yoshinari, S. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.07.016 · Cited by 197 · see citing works
Dejnabadi, H., Jolles, B. M., Casanova, E., Fua, P., & Aminian, K. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.873678 · Cited by 189 · see citing works
Magnetometer Calibration Using Inertial Sensors
Kok, M., & Schon, T. B. (2016) · IEEE Sensors Journal · doi:10.1109/jsen.2016.2569160 · Cited by 175 · see citing works
Bolink, S. A. A. N., Naisas, H., Senden, R., Essers, H., Heyligers, I. C., Meijer, K., & Grimm, B. (2016) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2015.11.009 · Cited by 147 · see citing works
Neurological Tremor: Sensors, Signal Processing and Emerging Applications
Grimaldi, G., & Manto, M. (2010) · Sensors · doi:10.3390/s100201399 · Cited by 138 · cited 1× · see citing works
“This is explained by the movement artifacts added to the acceleration signals, which no longer allow consideration of the Z axis as pure gravity acceleration [4].”
BackgroundBouvier, B., Duprey, S., Claudon, L., Dumas, R., & Savescu, A. (2015) · Sensors · doi:10.3390/s150818813 · Cited by 133 · see citing works
Benchmarking of a full-body inertial motion capture system for clinical gait analysis
Cloete, T., & Scheffer, C. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4650232 · Cited by 131 · see citing works
Feasibility of using inertial sensors to assess human movement
Saber-Sheikh, K., Bryant, E. C., Glazzard, C., Hamel, A., & Lee, R. (2009) · Manual Therapy · doi:10.1016/j.math.2009.05.009 · Cited by 128 · see citing works
Measurement of Upper Limb Range of Motion Using Wearable Sensors: A Systematic Review
Walmsley, C. P., Williams, S. A., Grisbrook, T., Elliott, C., Imms, C., & Campbell, A. (2018) · Sports Medicine - Open · doi:10.1186/s40798-018-0167-7 · Cited by 123 · see citing works
Reducing Drifts in the Inertial Measurements of Wrist and Elbow Positions
Zhou, H., & Hu, H. (2009) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2009.2025065 · Cited by 120 · see citing works
Blair, S., Duthie, G., Robertson, S., Hopkins, W., & Ball, K. (2018) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2018.03.031 · Cited by 117 · see citing works
Valevicius, A. M., Jun, P. Y., Hebert, J. S., & Vette, A. H. (2018) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2018.02.011 · Cited by 116 · see citing works
Roetenberg, D., Baten, C. T. M., & Veltink, P. H. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903946 · Cited by 111 · see citing works
Leardini, A., Lullini, G., Giannini, S., Berti, L., Ortolani, M., & Caravaggi, P. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-136 · Cited by 110 · see citing works
Accuracy of inertial motion sensors in static, quasistatic, and complex dynamic motion
Godwin, A., Agnew, M., & Stevenson, J. (2009) · Journal of Biomechanical Engineering · doi:10.1115/1.4000109 · Cited by 107 · see citing works
Evaluation of a hybrid system for three-dimensional measurement of trunk posture in motion
Plamondon, A., Delisle, A., Larue, C., Brouillette, D., McFadden, D., Desjardins, P., & Larivière, C. (2007) · Applied Ergonomics · doi:10.1016/j.apergo.2006.12.006 · Cited by 102 · see citing works
Bauer, C. M., Rast, F. M., Ernst, M. J., Kool, J., Oetiker, S., Rissanen, S. M., Suni, J. H., & Kankaanpää, M. (2015) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2015.06.001 · Cited by 97 · see citing works
Pérez‐Rodríguez, R., Costa, U. M., Torrent, M., Sánchez, J. S., Opisso, E., Cáceres, C. A., Tormos, J. M., Medina-Casanovas, J., & Aguilera, E. J. G. (2010) · Sensors · doi:10.3390/s101210733 · Cited by 97 · see citing works
Schall, M. C., Fethke, N. B., Chen, H., Oyama, S., & Douphrate, D. I. (2016) · Ergonomics · doi:10.1080/00140139.2015.1079335 · Cited by 96 · see citing works
Mjøsund, H. L., Boyle, E., Kjær, P., Mieritz, R. M., Skallgård, T., & Kent, P. M. (2017) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-017-1489-1 · Cited by 89 · see citing works
Bergmann, J. H., Mayagoitia, R. E., & Smith, I. C. (2009) · Dynamic Medicine · doi:10.1186/1476-5918-8-3 · Cited by 88 · see citing works
Kinematics of Gait: New Method for Angle Estimation Based on Accelerometers
Djuric-Jovicic, M. D., Jovičić, N. S., & Popović, D. B. (2011) · Sensors · doi:10.3390/s111110571 · Cited by 84 · see citing works
Ha, T. H., Saber-Sheikh, K., Moore, A. P., & Jones, M. P. (2012) · Manual Therapy · doi:10.1016/j.math.2012.04.003 · Cited by 81 · see citing works
Fantozzi, S., Giovanardi, A., Magalhães, F. A., Di Michele, R., Cortesi, M., & Gatta, G. (2016) · Journal of Sports Sciences · doi:10.1080/02640414.2015.1088659 · Cited by 74 · see citing works
Implementing a Sensor Fusion Algorithm for 3D Orientation Detection with Inertial/Magnetic Sensors
Abyarjoo, F., Barreto, A. B., Cofino, J., & Ortega, F. R. (2014) · Lecture notes in electrical engineering · doi:10.1007/978-3-319-06773-5_41 · Cited by 73 · see citing works
Measurement of Multi-segment Foot Joint Angles During Gait Using a Wearable System
Rouhani, H., Favre, J., Crevoisier, X., & Aminian, K. (2012) · Journal of Biomechanical Engineering · doi:10.1115/1.4006674 · Cited by 72 · see citing works
Wireless orientation sensors: Their suitability to measure head movement for neck pain assessment
Jasiewicz, J. M., Treleaven, J. M., Condie, P., & Jull, G. A. (2006) · Manual Therapy · doi:10.1016/j.math.2006.07.005 · Cited by 66 · see citing works
Lebel, K., Boissy, P., Nguyen, H., & Duval, C. (2017) · BioMedical Engineering OnLine · doi:10.1186/s12938-017-0347-6 · Cited by 65 · see citing works
Pasciuto, I., Ligorio, G., Bergamini, E., Vannozzi, G., Sabatini, A. M., & Cappozzo, A. (2015) · Sensors · doi:10.3390/s150923983 · Cited by 62 · see citing works
Duc, C., Salvia, P., Lubansu, A., Feipel, V., & Aminian, K. (2014) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2013.09.002 · Cited by 61 · see citing works
Reliability and precision of 3D wireless measurement of scapular kinematics
van den Noort, J. C., Wiertsema, S. H., Hekman, K. M. C., Schönhuth, C. P., Dekker, J., & Harlaar, J. (2014) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-014-1186-2 · Cited by 60 · see citing works
Bergamini, E., Guillon, P., Camomilla, V., Pillet, H., Wafa Skalli, E., & Cappozzo, A. (2013) · Journal of Applied Biomechanics · doi:10.1123/jab.29.5.622 · Cited by 57 · see citing works
Buganè, F., Benedetti, M., D’Angeli, V., & Leardini, A. (2014) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-13-146 · Cited by 54 · see citing works
Dowling, A. V., Favre, J., & Andriacchi, T. P. (2011) · Journal of Biomechanical Engineering · doi:10.1115/1.4004413 · Cited by 52 · see citing works
Ertzgaard, P., Öhberg, F., Gerdle, B., & Grip, H. (2016) · Manual Therapy · doi:10.1016/j.math.2015.09.004 · Cited by 41 · see citing works
de Oliveira, F. C. L., Bouyer, L. J., Ager, A. L., & Roy, J. (2017) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2017.06.002 · Cited by 38 · see citing works
Self-citationSchiefer, C., Kraus, T., Ellegast, R. P., & Ochsmann, E. (2015) · Journal of Occupational Medicine and Toxicology · doi:10.1186/s12995-015-0058-5 · Cited by 31 · see citing works
A novel motion tracking system for evaluation of functional rehabilitation of the upper limbs.
Gil-Agudo, A. M., Reyes-Guzmán, A. D. L., Dimbwadyo-Terrer, I., Peñasco-Martín, B., Bernal-Sahún, A., López-Monteagudo, P., del‐Ama, A. J., & Pons, J. L. (2013) · PubMed Central · doi:10.3969/j.issn.1673-5374.2013.19.005 · Cited by 30 · see citing works
Saito, H., & Watanabe, T. (2011) · IEICE Transactions on Information and Systems · doi:10.1587/transinf.e94.d.1716 · Cited by 29 · see citing works
Kumar, Y., Yen, S., Tay, A. E., Lee, W., Gao, F., Zhao, Z., Li, J., Hon, B., Xu, T., Cheong, A., et al. (2015) · Healthcare Technology Letters · doi:10.1049/htl.2014.0100 · Cited by 28 · see citing works
Kim, H., Shin, S.-H., Kim, J.-K., Park, Y.-J., Oh, H.-S., & Park, Y.-B. (2013) · Evidence-Based Complementary and Alternative Medicine · doi:10.1155/2013/570428 · Cited by 26 · see citing works
Reliability and validity of instrumented soccer equipment
Akins, J. S., Heebner, N. R., Lovalekar, M., & Sell, T. C. (2015) · Journal of Applied Biomechanics · doi:10.1123/jab.2014-0191 · Cited by 17 · see citing works
A novel motion tracking system for evaluation of functional rehabilitation of the upper limbs
Angel, A., GiI-Agudo, Ana, A., et al. (2013) · 中国神经再生研究:英文版 · Cited by 17 · see citing works
Portable Inertial Motion Unit for Continuous Assessment of In-shoe Foot Movement
Mifsud, N. L., Kristensen, N. H., Villumsen, M., Hansen, J., & Kersting, U. G. (2014) · Procedia Engineering · doi:10.1016/j.proeng.2014.06.035 · Cited by 16 · see citing works
Individual characteristics of reliable lumbar coupling motions
Yun, W.-S., Kim, H., Ahn, J. H., Park, Y.-B., & Park, Y.-J. (2015) · European Spine Journal · doi:10.1007/s00586-015-4081-0 · Cited by 16 · see citing works
Mobile Sensor Application for Kinematic Detection of the Knees
Jaysrichai, T., Suputtitada, A., & Khovidhungij, W. (2015) · Annals of Rehabilitation Medicine · doi:10.5535/arm.2015.39.4.599 · Cited by 16 · see citing works
Evaluation of suitability of a micro-processing unit of motion analysis for upper limb tracking
Madrigal, J. A. B., Cardiel, E., Rogeli, P., Salas, L. L., & Muñoz, R. (2016) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2016.04.011 · Cited by 13 · see citing works
Flagged first, then by citations
1 of the 70 references couldn’t be matched to a known paper.
Cited by
Sorted by citations
Kobsar, D., Charlton, J. M., Tse, C. T. F., Esculier, J.-F., Graffos, A., Krowchuk, N. M., Thatcher, D., & Hunt, M. A. (2020) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-020-00685-3 · Cited by 324 · see citing works
Hulleck, A. A., Mohan, D. M., Abdallah, N., Rich, M. E., & Khalaf, K. A. (2022) · Frontiers in Medical Technology · doi:10.3389/fmedt.2022.901331 · Cited by 302 · see citing works
Effect of Variability on Cronbach Alpha Reliability in Research Practice
Amirrudin, M., Nasution, K., & Supahar, S. (2020) · Jurnal Matematika Statistika dan Komputasi · doi:10.20956/jmsk.v17i2.11655 · Cited by 299 · see citing works
Wang, C., He, T., Zhou, H., Zhang, Z., & Lee, C. (2023) · Bioelectronic Medicine · doi:10.1186/s42234-023-00118-1 · Cited by 295 · see citing works
Ergonomic postural assessment using a new open-source human pose estimation technology (OpenPose)
Kim, W., Sung, J., Saakes, D. P., Huang, C., & Xiong, S. (2021) · International Journal of Industrial Ergonomics · doi:10.1016/j.ergon.2021.103164 · Cited by 192 · see citing works
Gait analysis in neurological populations: Progression in the use of wearables
Çelik, Y., Stuart, S., Woo, W. L., & Godfrey, A. (2020) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2020.11.005 · Cited by 169 · see citing works
Wearable inertial sensors for human movement analysis: a five-year update
Picerno, P., Iosa, M., D’Souza, C., Benedetti, M. G., Paolucci, S., & Morone, G. (2021) · Expert Review of Medical Devices · doi:10.1080/17434440.2021.1988849 · Cited by 146 · see citing works
Use of wearable sensor technology in gait, balance, and range of motion analysis
Díaz, S., Stephenson, J. B., & Labrador, M. A. (2019) · Applied Sciences · doi:10.3390/app10010234 · Cited by 132 · see citing works
Roggio, F., Ravalli, S., Maugeri, G., Bianco, A., Palma, A., Rosa, M. D., & Musumeci, G. (2021) · World Journal of Orthopedics · doi:10.5312/wjo.v12.i7.467 · Cited by 125 · see citing works
A Review of Artificial Intelligence and Robotics in Transformed Health Ecosystems
Denecke, K., & Baudoin, C. R. (2022) · Frontiers in Medicine · doi:10.3389/fmed.2022.795957 · Cited by 102 · see citing works
Nijmeijer, E. M., Heuvelmans, P., Bolt, R., Gokeler, A., Otten, E., & Benjaminse, A. (2023) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2023.111637 · Cited by 101 · see citing works
Determining anatomical frames via inertial motion capture: A survey of methods
Vitali, R. V., & Perkins, N. C. (2020) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2020.109832 · Cited by 100 · see citing works
Wearable Inertial Sensors for Gait Analysis in Adults with Osteoarthritis—A Scoping Review
Kobsar, D., Masood, Z., Khan, H., Khalil, N., Kiwan, M. Y., Ridd, S., & Tobis, M. (2020) · Sensors · doi:10.3390/s20247143 · Cited by 99 · see citing works
Spencer, J., Wolf, S. L., & Kesar, T. M. (2021) · Frontiers in Neurology · doi:10.3389/fneur.2021.637199 · Cited by 92 · see citing works
Paolo, S. D., Lopomo, N. F., Villa, F. D., Paolini, G., Figari, G., Bragonzoni, L., Grassi, A., & Zaffagnini, S. (2021) · Sensors · doi:10.3390/s21072331 · Cited by 85 · see citing works
Pacher, L., Châtellier, C., Vauzelle, R., & Fradet, L. (2020) · Sensors · doi:10.3390/s20113322 · Cited by 83 · see citing works
Huang, C., Kim, W., Zhang, Y., & Xiong, S. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17176050 · Cited by 77 · see citing works
Novel technology in sports biomechanics: some words of caution
Hughes, G., Camomilla, V., Vanwanseele, B., Harrison, A. J., Fong, D. T.-P., & Bradshaw, E. (2021) · Sports Biomechanics · doi:10.1080/14763141.2020.1869453 · Cited by 74 · see citing works
Conversion of Upper-Limb Inertial Measurement Unit Data to Joint Angles: A Systematic Review
Fang, Z., Woodford, S. C., Senanayake, D., & Ackland, D. C. (2023) · Sensors · doi:10.3390/s23146535 · Cited by 73 · see citing works
Park, S., & Yoon, S. (2021) · Sensors · doi:10.3390/s21113667 · Cited by 72 · see citing works
Dindorf, C., Teufl, W., Taetz, B., Bleser, G., & Fröhlich, M. (2020) · Sensors · doi:10.3390/s20164385 · Cited by 71 · see citing works
Lebleu, J., Gosseye, T. P., Detrembleur, C., Mahaudens, P., Cartiaux, O., & Penta, M. (2020) · Sensors · doi:10.3390/s20030715 · Cited by 69 · see citing works
Zeng, Z., Liu, Y., Hu, X., Tang, M., & Wang, L. (2022) · Sports Medicine - Open · doi:10.1186/s40798-022-00477-0 · Cited by 69 · see citing works
Poitras, I., Bielmann, M., Campeau‐Lecours, A., Mercier, C., Bouyer, L. J., & Roy, J. (2019) · Sensors · doi:10.3390/s19081885 · Cited by 65 · see citing works
Self-citationA Wearable Sensor System for Physical Ergonomics Interventions Using Haptic Feedback
Lind, C. M., Diaz-Olivares, J. A., Lindecrantz, K., & Eklund, J. A. E. (2020) · Sensors · doi:10.3390/s20216010 · Cited by 62 · see citing works
Alshahrani, M. S., & Reddy, R. S. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph19052792 · Cited by 59 · see citing works
The importance of inertial measurement unit placement in assessing upper limb motion
Höglund, G., Grip, H., & Öhberg, F. (2021) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2021.03.010 · Cited by 58 · see citing works
Ergonomic Design of a Workplace Using Virtual Reality and a Motion Capture Suit
Kačerová, I., Kubr, J., Hořejší, P., & Kleinová, J. (2022) · Applied Sciences · doi:10.3390/app12042150 · Cited by 58 · see citing works
Hindle, B. R., Keogh, J., & Lorimer, A. V. (2021) · Applied Bionics and Biomechanics · doi:10.1155/2021/6628320 · Cited by 57 · see citing works
Validation of the Perception Neuron system for full-body motion capture
Choo, C. Z. Y., Chow, J. Y., & Komar, J. (2022) · PLoS ONE · doi:10.1371/journal.pone.0262730 · Cited by 57 · see citing works
Camp, C. L., Loushin, S. R., Nezlek, S., Fiegen, A. P., Christoffer, D., & Kaufman, K. R. (2021) · The American Journal of Sports Medicine · doi:10.1177/03635465211029017 · Cited by 55 · see citing works
Upper Body Pose Estimation Using Wearable Inertial Sensors and Multiplicative Kalman Filter
Baldi, T. L., Farina, F., Garulli, A., Giannitrapani, A., & Prattichizzo, D. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2940612 · Cited by 54 · see citing works
Gait Impairment in Traumatic Brain Injury: A Systematic Review
Dever, A., Powell, D., Graham, L., Mason, R., Das, J., Marshall, S. J., Vitório, R. R., Godfrey, A., & Stuart, S. (2022) · Sensors · doi:10.3390/s22041480 · Cited by 51 · see citing works
Saggio, G., Tombolini, F., & Ruggiero, A. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.3016642 · Cited by 51 · see citing works
Sabino, I., Fernandes, M. D. C., Cepeda, C., Quaresma, C., Gamboa, H. F. S., Nunes, I. L., & Gabriel, A. T. (2024) · International Journal of Industrial Ergonomics · doi:10.1016/j.ergon.2024.103570 · Cited by 48 · see citing works
Shuai, Z., Dong, A., Liu, H., & Cui, Y. (2022) · Sensors · doi:10.3390/s22030863 · Cited by 43 · see citing works
Jourdan, T., Debs, N., & Frindel, C. (2021) · Sensors · doi:10.3390/s21144808 · Cited by 43 · see citing works
IMU-Based Systems for Upper-Limb Kinematic Analysis in Clinical Applications: A Systematic Review
Favata, A., Gallart-Agut, R., Pàmies‐Vilà, R., Carme Torras, A., & Font-Llagunes, J. M. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3436532 · Cited by 42 · see citing works
Wu, R., Li, M., Yao, Z., Liu, W., Si, J., & Huang, H. (2022) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2022.3179420 · Cited by 38 · see citing works
Beshara, P., Chen, J. F., Read, A. C., Lagadec, P., Wang, T., & Walsh, W. R. (2020) · Sensors · doi:10.3390/s20247238 · Cited by 37 · see citing works
Mundt, M., Koeppe, A., Bamer, F., David, S., & Markert, B. A. (2020) · Sensors · doi:10.3390/s20164581 · Cited by 35 · see citing works
Concurrent validity of an inertial measurement system in tennis forehand drive
Pedro, B., Cabral, S., & Veloso, A. (2021) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2021.110410 · Cited by 34 · see citing works
Cuadrado, J., Michaud, F., Lugrís, U., & Soto, M. P. (2021) · Sensors · doi:10.3390/s21020427 · Cited by 33 · see citing works
Upper Limb Movement Measurement Systems for Cerebral Palsy: A Systematic Literature Review
Francisco-Martínez, C., Prado-Olivarez, J., Padilla-Medina, J. A., Díaz-Carmona, J., Pérez-Pinal, F. J., Gutiérrez, A. I. B., & Nolasco, J. J. M. (2021) · Sensors · doi:10.3390/s21237884 · Cited by 33 · see citing works
Carmona-Pérez, C., Garrido-Castro, J. L., Vidal, F. T., Alcaraz-Clariana, S., García-Luque, L., Alburquerque‐Sendín, F., & Rodrigues‐de‐Souza, D. P. (2020) · Diagnostics · doi:10.3390/diagnostics10020080 · Cited by 32 · see citing works
Chia, L., Andersen, J. T., McKay, M. J., Sullivan, J., Megalaa, T., & Pappas, E. (2021) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2021.102589 · Cited by 32 · see citing works
Heuvelmans, P., Benjaminse, A., Bolt, R., Baumeister, J., Otten, E., & Gokeler, A. (2022) · Sports Biomechanics · doi:10.1080/14763141.2022.2093264 · Cited by 29 · see citing works
Meng, L., Martínez-Hernández, U., Childs, C. R., Dehghani-Sanij, A. A., & Buis, A. W. P. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2938764 · Cited by 29 · see citing works
Dupuis, F., Sole, G., Wassinger, C. A., Bielmann, M., Bouyer, L. J., & Roy, J. (2021) · PLoS ONE · doi:10.1371/journal.pone.0249403 · Cited by 29 · see citing works
Self-citationGuignard, B., Ayad, O., Baillet, H., Mell, F., Escobar, D. S., Boulanger, J., & Seifert, L. (2021) · Sports Biomechanics · doi:10.1080/14763141.2021.1945136 · Cited by 29 · see citing works
Movement Quality: A Novel Biomarker Based on Principles of Neuroscience
Solnik, S., Furmanek, M. P., & Piscitelli, D. (2020) · Neurorehabilitation and neural repair · doi:10.1177/1545968320969936 · Cited by 27 · see citing works
Inertial Sensor-to-Segment Calibration for Accurate 3D Joint Angle Calculation for Use in OpenSim
Raimondo, G. D., Vanwanseele, B., van der Have, A., Emmerzaal, J., Willems, M., Killen, B. A., & Jonkers, I. (2022) · Sensors · doi:10.3390/s22093259 · Cited by 27 · see citing works
Wu, Y., Tao, K., Chen, Q., Tian, Y., & Sun, L. (2022) · Sensors · doi:10.3390/s22186954 · Cited by 27 · see citing works
Ekdahl, M., Loewen, A., Erdman, A. L., Sahin, S., & Ulman, S. M. (2023) · Sensors · doi:10.3390/s23187987 · Cited by 26 · see citing works
Tröbinger, M., Costinescu, A., Xing, H., Elsner, J., Hu, T., Naceri, A., Figueredo, L., Jensen, E., Burschka, D., & Haddadin, S. (2021) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros51168.2021.9636626 · Cited by 26 · see citing works
A Flexible Sensor and MIMU-Based Multisensor Wearable System for Human Motion Analysis
Gu, Y. X., Han, Y., Liu, X., Zhang, N., Zhang, X., Pan, M., Wang, S., Dong, W., & Liu, T. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2022.3233653 · Cited by 25 · see citing works
Paolo, S. D., Bragonzoni, L., Villa, F. D., Grassi, A., & Zaffagnini, S. (2022) · Sports Biomechanics · doi:10.1080/14763141.2022.2080105 · Cited by 24 · see citing works
Zhang, C., Zhang, L., Tian, Y., An, Z., Li, B., & Li, D. (2025) · eScience · doi:10.1016/j.esci.2025.100373 · Cited by 23 · see citing works
Berner, K., Cockcroft, J., & Louw, Q. A. (2020) · BioMedical Engineering OnLine · doi:10.1186/s12938-020-00802-2 · Cited by 23 · see citing works
Carcreff, L., Grouvel, G., Payen, G., Massé, F., & Armand, S. (2022) · Sensors · doi:10.3390/s22155657 · Cited by 23 · see citing works
Validation of pitchAI TM markerless motion capture using marker-based 3D motion capture
Dobos, T., Bench, R. W. G., McKinnon, C. D., Brady, A., Boddy, K. J., Holmes, M. W. R., & Sonne, M. W. L. (2022) · Sports Biomechanics · doi:10.1080/14763141.2022.2137425 · Cited by 23 · see citing works
Edwards, N. A., Talarico, M., Chaudhari, A. M. W., Mansfield, C. J., & Oñate, J. A. (2023) · Applied Ergonomics · doi:10.1016/j.apergo.2023.103991 · Cited by 23 · see citing works
The future of footwear biomechanics research
Willwacher, S., & Weir, G. (2023) · Footwear Science · doi:10.1080/19424280.2023.2199011 · Cited by 23 · see citing works
Hindle, B. R., Keogh, J., & Lorimer, A. V. (2020) · Sensors · doi:10.3390/s20164586 · Cited by 23 · see citing works
Evaluation of Hemiplegic Gait Based on Plantar Pressure and Inertial Sensors
Pan, Z., Gao, H., Chen, Y., Xie, Z., & Xie, L. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3268669 · Cited by 22 · see citing works
Thiry, P., Houry, M., Philippe, L., Nocent, O., Buisseret, F., Dierick, F., Slama, R., Bertucci, W., Thévenon, A., & Simoneau-Buessinger, É. (2022) · Sensors · doi:10.3390/s22135027 · Cited by 20 · see citing works
Stamm, O., & Steinert, A. (2020) · JMIR mhealth and uhealth · doi:10.2196/19608 · Cited by 20 · see citing works
A Textile Sensor for Long Durations of Human Motion Capture
Hu, S., Dai, M., Dong, T., & Liu, T. (2019) · Sensors · doi:10.3390/s19102369 · Cited by 19 · see citing works
Goreham, J. A., MacLean, K. F. E., & Ladouceur, M. (2022) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2022.111000 · Cited by 19 · see citing works
Zeng, Z., Liu, Y., Li, P., & Wang, L. (2022) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2022.1005496 · Cited by 19 · see citing works
"Artificial Intelligence in Veterinary Care: A Review of Applications for Animal Health
Al-Badrani, B. A., Abdel-Raheem, M., & Al-Farwachi, M. I. (2024) · Egyptian Journal of Veterinary Science · doi:10.21608/ejvs.2024.260989.1769 · Cited by 19 · see citing works
Michaud, F., Soto, M. P., Lugrís, U., & Cuadrado, J. (2021) · Sensors · doi:10.3390/s21165487 · Cited by 19 · see citing works
Li, J., Qiu, F., Gan, L., & Chou, L. (2024) · Wearable Technologies · doi:10.1017/wtc.2024.6 · Cited by 18 · see citing works
Bissenov, A., Zhubi, E., Engh, M. A., Gresits, O., Tóth, R., & Terebessy, T. (2025) · Journal of Orthopaedic Surgery and Research · doi:10.1186/s13018-025-06322-w · Cited by 18 · see citing works
Faliagka, E., Skarmintzos, V., Panagiotou, C., Syrimpeis, V. N., Antonopoulos, C., & Voros, N. S. (2023) · Electronics · doi:10.3390/electronics12163375 · Cited by 18 · see citing works
Patel, G., Mullerpatan, R., Agarwal, B. M., Shetty, T., Ojha, R., Mohammed, J. S., & Sujatha, S. N. N. (2022) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/09544119211072971 · Cited by 17 · see citing works
Flexible sensor-based biomechanical evaluation of low-back exoskeleton use in lifting
Yin, W., Chen, Y., Reddy, C. P., Zheng, L., Mehta, R. K., & Zhang, X. (2023) · Ergonomics · doi:10.1080/00140139.2023.2216408 · Cited by 17 · see citing works
Impact of fatigue at the shoulder on the contralateral upper limb kinematics and performance
Dupuis, F., Sole, G., Mercier, C., & Roy, J. (2022) · PLoS ONE · doi:10.1371/journal.pone.0266370 · Cited by 17 · see citing works
Self-citationLin, Y., Price, K., Carmichael, D. S., Maniar, N., Hickey, J. T., Timmins, R. G., Heiderscheit, B. C., Blemker, S. S., & Opar, D. A. (2023) · Sensors · doi:10.3390/s23239599 · Cited by 16 · see citing works
Plaza-Bravo, J. M., Mateo‐March, M., Sanchís-Sanchís, R., Pérez‐Soriano, P., Zabala, M., & Martínez, A. E. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph19148375 · Cited by 16 · see citing works
Baets, L. D., Vanbrabant, S., Dierickx, C., van der Straaten, R., & Timmermans, A. A. A. (2020) · Sensors · doi:10.3390/s20030876 · Cited by 16 · see citing works
González-Alonso, J., Martín-Tapia, P., González‐Ortega, D., Antón‐Rodríguez, M., Pernas, F. J. D., & Martínez‐Zarzuela, M. (2025) · Expert Systems with Applications · doi:10.1016/j.eswa.2025.127212 · Cited by 15 · see citing works
Bioengineering Support in the Assessment and Rehabilitation of Low Back Pain
Varrassi, G., Leoni, M. L. G., Al-Alwany, A. A., Sarzi‐Puttini, P., & Farì, G. (2025) · Bioengineering · doi:10.3390/bioengineering12090900 · Cited by 15 · see citing works
Meng, L., Chen, M., Li, B., He, F., Xu, R., & Ming, D. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2022.3233344 · Cited by 15 · see citing works
IMU positioning affects range of motion measurement during squat motion analysis
Blandeau, M., Guichard, R., Hubaut, R., & Leteneur, S. (2023) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2023.111598 · Cited by 15 · see citing works
Textile-Sensing Wearable Systems for Continuous Motion Angle Estimation: A Systematic Review
Zhang, R., Chen, L., Hu, Y., Zhang, Y., Chen, J., Liang, T., Sun, X., & Wang, Q. (2023) · International Journal of Human-Computer Interaction · doi:10.1080/10447318.2023.2276991 · Cited by 15 · see citing works
Uhlenberg, L., & Amft, O. (2024) · Frontiers in Computer Science · doi:10.3389/fcomp.2024.1347424 · Cited by 15 · see citing works
Bini, R. R. (2020) · Journal of Sports Sciences · doi:10.1080/02640414.2020.1816289 · Cited by 15 · see citing works
Lyle, M. A., Jensen, J. C., Hunnicutt, J. L., Brown, J. J., Chambliss, C. P., Newsome, M., Xerogeanes, J. W., & Tsai, L. (2021) · Journal of Athletic Training · doi:10.4085/1062-6050-0186.21 · Cited by 15 · see citing works
Emmerzaal, J., Rossom, S. V., van der Straaten, R., Brabandere, A. D., Corten, K., Baets, L. D., Davis, J., Jonkers, I., Timmermans, A. A. A., & Vanwanseele, B. (2022) · Journal of Orthopaedic Research® · doi:10.1002/jor.25269 · Cited by 14 · see citing works
da Silva, R. S., da Silva, S. T., Cardoso, D. C. R., Quirino, M. A. F., Silva, M. H. A., Gomes, L. A., Fernandes, J. D., Oliveira, R., Fernandes, A. B. G. S., & Ribeiro, T. S. (2024) · Gait & Posture · doi:10.1016/j.gaitpost.2024.08.004 · Cited by 14 · see citing works
Quixadá, A. P., Miranda, J., Osypiuk, K., Bonato, P., Vergara-Diaz, G., Ligibel, J., Mehling, W., Thompson, E., & Wayne, P. (2022) · Frontiers in Psychology · doi:10.3389/fpsyg.2022.800727 · Cited by 10 · see citing works
Musculoskeletal modelling and simulation of oil palm fresh fruit bunch harvesting
Chan, Y. S., Teo, Y. X., Gouwanda, D., Nurzaman, S. G., Gopalai, A. A., & Thannirmalai, S. (2022) · Scientific Reports · doi:10.1038/s41598-022-12088-6 · Cited by 14 · see citing works
Villa, G., Cerfoglio, S., Bonfiglio, A., Capodaglio, P., Galli, M., & Cimolin, V. (2025) · Sensors · doi:10.3390/s25123736 · Cited by 13 · see citing works
Chaikho, L., Clark, E., & Raison, M. (2022) · Sensors · doi:10.3390/s22249812 · Cited by 13 · see citing works
The validity of a single inertial sensor to assess cervical active range of motion
English, D. J., Weerakkody, N., Zacharias, A., Green, R. A., Hocking, C., & Bini, R. R. (2023) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2023.111781 · Cited by 13 · see citing works
Carvalho, A., Vanrenterghem, J., Cabral, S., Assunção, A., Fernandes, R. S., Veloso, A., & Moniz-Pereira, V. (2024) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2024.112280 · Cited by 13 · see citing works
Bini, R. R., & Hume, P. A. (2020) · Sports Biomechanics · doi:10.1080/14763141.2020.1776760 · Cited by 13 · see citing works
Oliva‐Lozano, J. M., Maraver, E. F., Fortes, V., & Muyor, J. M. (2020) · Sensors · doi:10.3390/s20215971 · Cited by 13 · see citing works
Kinect v2-Assisted Semi-Automated Method to Assess Upper Limb Motor Performance in Children
Francisco-Martínez, C., Padilla-Medina, J. A., Prado-Olivarez, J., Pérez-Pinal, F. J., Gutiérrez, A. I. B., & Nolasco, J. J. M. (2022) · Sensors · doi:10.3390/s22062258 · Cited by 13 · see citing works
- Authors
- Poitras, I., Dupuis, F., Bielmann, M., Campeau-Lecours, A., Mercier, C., Bouyer, L., & Roy, J.-S.
- Affiliations
- Université Laval (CA)
- Centre for Interdisciplinary Research in Rehabilitation and Social Integration and Université Laval, Quebec City, QC G1M 2S8, Canada
- Corresponding author
- Roy, Jean-Sébastien
- ORCID
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2019-03-31
- Volume
- 19
- Issue
- 7
- Pages
- 1555
- ISSN
- 1424-8220 (ISSN-L)
- PMC
- PMC6479822
- OpenAlex
- W2935004960
- Semantic Scholar
- f7f3937fe66d64415669b70ed28455e098c74bda
- Cited by
- 309
- References
- 70
- Citations by year
- 2026: 35 · 2025: 41 · 2024: 45 · 2023: 47 · 2022: 59 · 2021: 36 · 2020: 40 · 2019: 6
- FWCI
- 3.74
- Type
- journal article
- Language
- en
- Open access
- gold
- dx.doi.org
- Licence
- Locations
- Sensors (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- Canadian Institutes of Health Research
- Fonds de Recherche du Québec - Santé
- Topics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Physical Sciences › Engineering › Biomedical Engineering › Lower Extremity Biomechanics and Pathologies
- Physical Sciences › Engineering › Aerospace Engineering › Inertial Sensor and Navigation
- Keywords
- wearable sensors, inertial measurement unit, joint angle estimation, criterion validity, reliability statistics, range of motion, motion capture alternative, task complexity, lower limb joints
- MeSH terms
- Wearable Electronic Devices, Humans, Joints, Movement, Reproducibility of Results, Range of Motion, Articular, Databases, Factual, Accelerometry
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Claims read by deepseek-v4.1-flash under definition version 3 (extract-v3) on 2026-10-09.
Classified by jev-1.13-20260917 (gold-guideline-v0.2) on 2026-10-09.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review