CoChat

Gain effects on performance using a head-controlled computer input device

LIN, MEI LI, RADWIN, ROBERT G., VANDERHEIDEN, GREGG C. · 1992 · Ergonomics
Cited by 74

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

The purpose of this study was to use a Fitts' task to (1) determine how control-display gain influences performance using a head-controlled computer input device; (2) compare relative sensitivity to gain and optimal gain between head control and hand/arm control; and (3) investigate control-display gain interactions with other task factors including target width, movement amplitude and direction. The task was a discrete target acquisition task using circular targets of 2.9 mm, 8.1 mm, and 23.5 mm, movement amplitudes of 24.3 mm and 61.7 mm, and eight radial directions including 0 degrees, 45 degrees, 90 degrees, 135 degrees, 180 degrees, 225 degrees, 270 degrees, and 315 degrees. Each device was operated at four gain levels. Ten subjects participated. The results indicated that gain had a significant effect on movement time for both types of pointing devices and exhibited local minimums. Discrete target acquisition at all gains was aptly described using Fitts' Law for both input devices. The mouse gain resulting in minimum movement time and RMS cursor deviation was between 1.0 and 2.0. The minimum movement time and RMS cursor deviation for the head-controlled pointer occurred at a gain between 0.3 and 0.6. Average movement time at the optimal head-controlled pointer gain had a slope of 169 ms/bit and was more than 76% greater than at the optimal mouse gain with a slope of 135 ms/bit. In addition, average RMS displacement was more than 27% greater for the head-controlled pointer at its optimal gain setting than for the mouse. Gain had the greatest effect for small target widths and long movement amplitudes using the head-controlled pointer. Average movement time increased 37% when increasing the head-controlled pointer gain from 0.6 to 1.2 for the small target width, but only increased 0.3% when increasing gain for the large target width. Average movement time also increased 12% when decreasing the head-controlled pointer gain from 0.3 to 0.15 for the long movement amplitude, but decreased 0.3% when decreasing gain for the short movement amplitude.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/00140139208967804

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 74

Metadata

Authors
LIN, M. L., RADWIN, R. G., & VANDERHEIDEN, G. C.
Venue
Ergonomics
Published
1992-02
Volume
35
Issue
2
Pages
159-175
ISSN
  • 0014-0139 (ISSN-L)
  • 1366-5847
OpenAlex
W1995416156
Cited by
74
References
3
FWCI
0.60
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Gain effects on performance using a head-controlled computer input device. https://app.cochat.ai/papers/10.1080/00140139208967804
The paper
LIN, M. L., RADWIN, R. G., & VANDERHEIDEN, G. C. (1992). Gain effects on performance using a head-controlled computer input device. Ergonomics. https://doi.org/10.1080/00140139208967804

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.