The impact of activity level on sweat accumulation and thermal comfort using different underwear
The DOI matches its Crossref record.
Abstract
The purpose of this study was to investigate the significance of work level and sweat production for the total amount accumulated and the location of the sweat in a three-layer ensemble as a function of material and textile construction. Furthermore, it was also an aim to investigate how this influenced thermoregulatory responses and thermal comfort during work and during a rest period. Long-legged/long-sleeved underwear manufactured from two different 100% fibre-type materials, polypropylene and wool, was tested as part of a three-layer clothing system. The underwear manufactured from 100% polypropylene was tested in two different knit constructions, a 1-by-1 rib knit and a fishnet structure, and the woollen underwear in a 1-by-1 rib knit construction. The test was performed on eight male subjects (Ta = 10 degrees C, RH = 85%, Va < 0.1 m/s), and comprised a twice-repeated bout of 40-min cycle exercise followed by 20 min rest. Each subject conducted two tests with the work level approximating 30% VO2 max and 40% VO2 max, respectively. Skin temperatures, rectal temperature, weight loss and humidity near the skin were recorded during the test. Total changes in body and clothing weight were measured separately. Furthermore, subjective ratings on thermal comfort and on sensation of temperature and humidity were collected. The results demonstrated that high heat and sweat production during work periods, leading to increased sweat accumulation, will give higher thermal discomfort ratings for rest periods as well as for work periods compared to intermittent work with lower work intensities. Distribution of accumulated sweat in the clothing ensemble after heavy sweating is dependent on the fibre type in the underwear. Further, it can be concluded that underwear construction clearly has an influence on the evaporation rate in a three-layer ensemble during work at a high activity level.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Body mapping of sweating patterns in male athletes in mild exercise-induced hyperthermia
Smith, C. J., & Havenith, G. (2011) · European Journal of Applied Physiology · doi:10.1007/s00421-010-1744-8 · Cited by 375
“Metabolic mass loss (g) was calculated from an equation taken from Bakkevig and Nielsen (1995), based upon Kerslake (1972, pp. 121): Metabolic mass loss ¼ _VO2ð44 RQ 32Þ 22:4 t ð3Þ where _VO2 is the rate of oxygen consumption (L min -1); RQ respiratory quotient (ND); t is the time (s).”
MethodHuman metabolic rate and thermal comfort in buildings: The problem and challenge
Luo, M., Wang, Z., Ke, K., Cao, B., Zhai, Y., & Zhou, X. (2018) · Building and Environment · doi:10.1016/j.buildenv.2018.01.005 · Cited by 231
Clothing and thermoregulation during exercise
Gavin, T. P. (2003) · Sports Medicine · doi:10.2165/00007256-200333130-00001 · Cited by 177
Metadata
- Authors
- BAKKEVIG, M. K., & NIELSEN, R.
- Venue
- Ergonomics
- Publisher
- Informa UK Limited
- Published
- 1995-05
- Volume
- 38
- Issue
- 5
- Pages
- 926-939
- ISSN
- 0014-0139 (ISSN-L)
- 1366-5847
- OpenAlex
- W2004833762
- Cited by
- 45
- References
- 0
- FWCI
- 1.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The impact of activity level on sweat accumulation and thermal comfort using different underwear. https://app.cochat.ai/papers/10.1080/00140139508925160
- The paper
- BAKKEVIG, M. K., & NIELSEN, R. (1995). The impact of activity level on sweat accumulation and thermal comfort using different underwear. Ergonomics. https://doi.org/10.1080/00140139508925160