A 3-parameter critical power model
The DOI matches its Crossref record.
Abstract
The critical power test is a well-established procedure that provides estimates of two important parameters characterizing work performance; anaerobic work capacity (AWC) and critical power (CP). The concept proscribes a hyperbolic relationship between power output (P) and time to exhaustion (t), given by (P - CP)t = AWC. Since evidence now exists that the procedure overestimates CP and underestimates AWC, this study was undertaken to investigate the effect of relaxing the requirement that the time asymptote necessarily be at zero. Using data from a previous study, it is shown that in so doing, (1) a time asymptote significantly less than zero is obtained, (2) significantly smaller estimates of CP and larger estimates of AWC are obtained, (3) a third parameter is introduced that theoretically represents maximal instantaneous power, (4) it implies that the maximal power that could be developed at any instant is proportional to the amount of AWC remaining at that instant, which in turn implies that (5) at exhaustion not necessary all of AWC is consumed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Critical Power: Implications for Determination of V˙O2max and Exercise Tolerance
JONES, A. M., VANHATALO, A., BURNLEY, M., MORTON, R. H., & POOLE, D. C. (2010) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181d9cf7f · Cited by 549
Billat, V. L., Sirvent, P., Py, G., Koralsztein, J.-P., & Mercier, J. (2003) · Sports Medicine · doi:10.2165/00007256-200333060-00003 · Cited by 397
Methods to Determine Aerobic Endurance
Bosquet, L., L??ger, L., & Legros, P. (2002) · Sports Medicine · doi:10.2165/00007256-200232110-00002 · Cited by 279
Jones, A. M., & Vanhatalo, A. (2017) · Sports Medicine · doi:10.1007/s40279-017-0688-0 · Cited by 259
Exercise Intensity Thresholds: Identifying the Boundaries of Sustainable Performance
KEIR, D. A., FONTANA, F. Y., ROBERTSON, T. C., MURIAS, J. M., PATERSON, D. H., KOWALCHUK, J. M., & POGLIAGHI, S. (2015) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000613 · Cited by 205
Metadata
- Authors
- HUGH MORTON, R.
- Venue
- Ergonomics
- Publisher
- Informa UK Limited
- Published
- 1996-03
- Volume
- 39
- Issue
- 4
- Pages
- 611-619
- ISSN
- 0014-0139 (ISSN-L)
- 1366-5847
- OpenAlex
- W2105699392
- Cited by
- 174
- References
- 0
- FWCI
- 5.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A 3-parameter critical power model. https://app.cochat.ai/papers/10.1080/00140139608964484
- The paper
- HUGH MORTON, R. (1996). A 3-parameter critical power model. Ergonomics. https://doi.org/10.1080/00140139608964484
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.