Effects of computer mouse design and task on carpal tunnel pressure
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
Computer mouse use has become an integral part of office work in the past decade. Intensive mouse use has been associated with increased risk of upper extremity musculoskeletal disorders, including carpal tunnel syndrome. Sustained, elevated fluid pressure in the carpal tunnel may play a role in the pathophysiology of carpal tunnel syndrome. Carpal tunnel pressure was measured in 14 healthy individuals while they performed tasks using three different computer mice. Participants performed a multidirectional dragging ('drag and drop') task starting with the hand resting (static posture) on the mouse. With one mouse, an additional pointing ('point-and-click') task was performed. All mice were associated with similar wrist extension postures (p = 0.41) and carpal tunnel pressures (p = 0.48). Pressures were significantly greater during dragging and pointing tasks than when resting the hand (static posture) on the mouse (p = 0.003). The mean pressures during the dragging tasks were 28.8-33.1 mmHg, approximately 12 mmHg greater than the static postures. Pressures during the dragging task were higher than the pointing task (33.1 versus 28.0 mmHg), although the difference was borderline non-significant (p = 0.06). In many participants the carpal tunnel pressures measured during mouse use were greater than pressures known to alter nerve function and structure, indicating that jobs with long periods of intensive mouse use may be at an increased risk of median mononeuropathy. A recommendation is made to minimize wrist extension, minimize prolonged dragging tasks and frequently perform other tasks with the mousing hand.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1956) · Observations on the Alewife, Pomolobus Pseudoharengus (Wilson), in Fresh Wate · doi:10.3138/9781487596026-005 · Cited by 1,534
The carpal tunnel syndrome. A study of carpal canal pressures.
Gelberman, R. H., Hergenroeder, P. T., Hargens, A. R., Lundborg, G. N., & Akeson, W. H. (1981) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198163030-00009 · Cited by 744
Lundborg, G., Gelberman, R. H., Minteer-Convery, M., Lee, Y. F., & Hargens, A. R. (1982) · The Journal of Hand Surgery · doi:10.1016/s0363-5023(82)80175-5 · Cited by 352
Lundborg, G., Myers, R., & Powell, H. (1983) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.46.12.1119 · Cited by 316
Repetitive Motion Disorders of the Upper Extremity
Gordon, S. L., Blair, S. J., Fine, L. J., & Musculoskeletal (1995) · Medical Entomology and Zoology · Cited by 240
The clinical measurement of joint motion
Greene, W. B., & Heckman, J. D. (1994) · Cited by 204
Pathology of experimental nerve compression.
Powell, H. C., & Myers, R. R. (1986) · PubMed · Cited by 195
Okutsu, I., Ninomiya, S., Hamanaka, I., Kuroshima, N., & Inanami, H. (1989) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198971050-00006 · Cited by 193
Weiss, N. D., Gordon, L., Bloom, T., So, Y., & Rempel, D. M. (1995) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199511000-00008 · Cited by 189
Self-citationPeripheral nerve-conduction block by high muscle-compartment pressure.
Hargens, A. R., Romine, J. S., Sipe, J. C., Evans, K. L., Mubarak, S. J., & Akeson, W. H. (1979) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197961020-00006 · Cited by 186 · cited 2×
“…to ~ 30 mmHg. Prolonged pressure of this magnitude has been associated with altered nerve function and structure in human and animal nerve studies (Hargens et al. 1979, Lundborg et al. 1983, Powell and Myers 1986, Dahlin et al. 1987) as well as eliciting symptoms of carpal tunnel syndrome when…”
Background
Cited by
Topp, K. S., & Boyd, B. S. (2006) · Physical Therapy · doi:10.1093/ptj/86.1.92 · Cited by 361
Sonne, M., Villalta, D. L., & Andrews, D. M. (2012) · Applied Ergonomics · doi:10.1016/j.apergo.2011.03.008 · Cited by 239
“Elevated pressure in the tissues surrounding nerves in the upper extremities has been shown to increase with sustained non-neutral postures, which may lead to further discomfort and injury (Keir et al.,1999).”
BackgroundA handy review of carpal tunnel syndrome: From anatomy to diagnosis and treatment
Ghasemi-rad, M. (2014) · World Journal of Radiology · doi:10.4329/wjr.v6.i6.284 · Cited by 179
Review Study of Computer Input Devices and Older Users
Taveira, A. D., & Choi, S. D. (2009) · International Journal of Human-Computer Interaction · doi:10.1080/10447310902865040 · Cited by 94
“Keir, Bach, and Rempel (1999) pointed out that intensive mouse use has been associated with increased risk of upper extremity MSDs, including carpal tunnel syndrome.”
BackgroundPerspectives on the postdigital: Beyond rhetorics of progress and novelty
Taffel, S. (2016) · Convergence: The International Journal of Research into New Media Technologies · doi:10.1177/1354856514567827 · Cited by 92
“…exploring human/computer interfaces and the material implications of our specific modes of interaction with digital computers such as carpal tunnel (Keir et al., 1999) and eye strain from display technologies (Blehm et al., 2005; Matula, 1981), clearly denoting the ways in which human interfaces…”
Background
Metadata
- Authors
- Keir, P. J., Bach, J. M., & Rempel, D.
- Venue
- Ergonomics
- Publisher
- Informa UK Limited
- Published
- 1999-10
- Volume
- 42
- Issue
- 10
- Pages
- 1350-1360
- ISSN
- 0014-0139 (ISSN-L)
- 1366-5847
- OpenAlex
- W2149552471
- Cited by
- 187
- References
- 17
- FWCI
- 5.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.