A brief guide to pyroelectric detectors
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The principles of operation of a pyroelectric detector are summarized and responsivity, noise, noise equivalent power and detectivity are derived. The relationship between responsivity and frequency is discussed as are the various sources of noise. There follows a discussion of the relative merits of the five principal pyroelectric materials in common use: Triglycine Sulphate, Lithium Tantalate, Strontium Barium Niobate, Pyroelectric Ceramics and Polyvinylidene Fluoride. Factors influencing the choice of material are outlined and summarized in performance curves for three sizes of detector. Mention is made of a variety of detector types currently available and some of the current applications. A very brief summary of possible future developments is included.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Thermal Agitation of Electricity in Conductors
Johnson, J. B. (1928) · Physical Review · doi:10.1103/physrev.32.97 · Cited by 1,811
Cited by
Short-circuit photocurrent in epitaxial lead zirconate-titanate thin films
Pintilie, L., Vrejoiu, I., Le Rhun, G., & Alexe, M. (2007) · Journal of Applied Physics · doi:10.1063/1.2560217 · Cited by 167
Metadata
- Authors
- Porter, S. G.
- Venue
- Ferroelectrics
- Publisher
- Informa UK Limited
- Published
- 1981-06
- Volume
- 33
- Issue
- 1
- Pages
- 193-206
- ISSN
- 0015-0193 (ISSN-L)
- 1563-5112
- OpenAlex
- W296244986
- Cited by
- 222
- References
- 1
- FWCI
- 2.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A brief guide to pyroelectric detectors. https://app.cochat.ai/papers/10.1080/00150198108008086
- The paper
- Porter, S. G. (1981). A brief guide to pyroelectric detectors. Ferroelectrics. https://doi.org/10.1080/00150198108008086
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.