CoChat

Implantable physiological power supply with PVDF film

Häsler, E., Stein, L., Harbauer, G. · 1984 · Ferroelectrics
Cited by 144

The DOI matches its Crossref record.

Abstract

A fraction of the energy expenditure for respiration can be converted into electric power to supply implants which require a permanent power source. Toward this goal the relative motion of the ribs can be used for periodical stretching of a converter. A miniaturized prototype with solid electrical and mechanical contacts has been designed. We describe here the physical characteristics of the device and present the first results of an animal experiment. With improved PVDF films, a power converter with a film mass of a few g could supply implanted electric systems with a power of 1 mW.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/00150198408017528

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 144

Metadata

Authors
Häsler, E., Stein, L., & Harbauer, G.
Venue
Ferroelectrics
Published
1984-10
Volume
60
Issue
1
Pages
277-282
ISSN
  • 0015-0193 (ISSN-L)
  • 1563-5112
OpenAlex
W2075791139
Cited by
144
References
0
FWCI
1.37
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Implantable physiological power supply with PVDF film. https://app.cochat.ai/papers/10.1080/00150198408017528
The paper
Häsler, E., Stein, L., & Harbauer, G. (1984). Implantable physiological power supply with PVDF film. Ferroelectrics. https://doi.org/10.1080/00150198408017528

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.