Implantable physiological power supply with PVDF film
The DOI matches its Crossref record.
Abstract
A fraction of the energy expenditure for respiration can be converted into electric power to supply implants which require a permanent power source. Toward this goal the relative motion of the ribs can be used for periodical stretching of a converter. A miniaturized prototype with solid electrical and mechanical contacts has been designed. We describe here the physical characteristics of the device and present the first results of an animal experiment. With improved PVDF films, a power converter with a film mass of a few g could supply implanted electric systems with a power of 1 mW.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Direct-Write Piezoelectric Polymeric Nanogenerator with High Energy Conversion Efficiency
Chang, C., Tran, V. H., Wang, J., Fuh, Y.-K., & Lin, L. (2010) · Nano Letters · doi:10.1021/nl9040719 · Cited by 1,379
A Review of Power Harvesting from Vibration Using Piezoelectric Materials
Sodano, H. A., Inman, D. J., & Park, G. (2004) · The Shock and Vibration Digest · doi:10.1177/0583102404043275 · Cited by 1,361
Flexible High-Output Nanogenerator Based on Lateral ZnO Nanowire Array
Zhu, G., Yang, R., Wang, S., & Wang, Z. L. (2010) · Nano Letters · doi:10.1021/nl101973h · Cited by 805
Novel Ferroelectric Polymers for High Energy Density and Low Loss Dielectrics
Zhu, L., & Wang, Q. (2012) · Macromolecules · doi:10.1021/ma2024057 · Cited by 683
Kinetic Energy Harvesting Using Piezoelectric and Electromagnetic Technologies—State of the Art
Khaligh, A., Zeng, P., & Zheng, C. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2024652 · Cited by 669
Comparison of Piezoelectric Energy Harvesting Devices for Recharging Batteries
Sodano, H. A., Inman, D. J., & Park, G. (2005) · Journal of Intelligent Material Systems and Structures · doi:10.1177/1045389x05056681 · Cited by 663
Parasitic power harvesting in shoes
Kymissis, J., Kendall, C., Paradiso, J., & Gershenfeld, N. (2002) · Digest of Papers. Second International Symposium on Wearable Computers (Cat. No.98EX215) · doi:10.1109/iswc.1998.729539 · Cited by 621
Piezoelectric Ribbons Printed onto Rubber for Flexible Energy Conversion
Qi, Y., Jafferis, N. T., Lyons, K., Lee, C. M., Ahmad, H., & McAlpine, M. C. (2010) · Nano Letters · doi:10.1021/nl903377u · Cited by 496
Piezoelectric nanofibers for energy scavenging applications
Chang, J., Dommer, M., Chang, C., & Lin, L. (2012) · Nano Energy · doi:10.1016/j.nanoen.2012.02.003 · Cited by 444
Muscle‐Driven In Vivo Nanogenerator
Li, Z., Zhu, G., Yang, R., Wang, A. C., & Wang, Z. L. (2010) · Advanced Materials · doi:10.1002/adma.200904355 · Cited by 441
Energy Harvesting for Structural Health Monitoring Sensor Networks
Park, G., Rosing, T., Todd, M. D., Farrar, C. R., & Hodgkiss, W. (2008) · Journal of Infrastructure Systems · doi:10.1061/(asce)1076-0342(2008)14:1(64 · Cited by 434
Piezoelectric energy harvesting: State-of-the-art and challenges
Toprak, A., & Tigli, O. (2014) · Applied Physics Reviews · doi:10.1063/1.4896166 · Cited by 417
Nanotechnology-enabled flexible and biocompatible energy harvesting
Qi, Y., & McAlpine, M. C. (2010) · Energy & Environmental Science · doi:10.1039/c0ee00137f · Cited by 395
Shepelin, N. A., Glushenkov, A. M., Lussini, V. C., Fox, P. J., Dicinoski, G. W., Shapter, J. G., & Ellis, A. V. (2019) · Energy & Environmental Science · doi:10.1039/c8ee03006e · Cited by 317
Energy Harvesting Research: The Road from Single Source to Multisource
Bai, Y., Jantunen, H., & Juuti, J. (2018) · Advanced Materials · doi:10.1002/adma.201707271 · Cited by 295
An investigation of energy harvesting from renewable sources with PVDF and PZT
Vatansever, D., Hadimani, R. L., Shah, T., & Siores, E. (2011) · Smart Materials and Structures · doi:10.1088/0964-1726/20/5/055019 · Cited by 278
Generation and Storage of Electricity from Power Harvesting Devices
Sodano, H. A., Inman, D. J., & Park, G. (2005) · Journal of Intelligent Material Systems and Structures · doi:10.1177/1045389x05047210 · Cited by 269
Fluoropolymer ferroelectrics: Multifunctional platform for polar-structured energy conversion
Qian, X., Chen, X., Zhu, L., & Zhang, Q. M. (2023) · Science · doi:10.1126/science.adg0902 · Cited by 265
Recent Advances in Nanogenerator‐Driven Self‐Powered Implantable Biomedical Devices
Parvez Mahmud, M. A., Huda, N., Farjana, S. H., Asadnia, M., & Lang, C. (2018) · Advanced Energy Materials · doi:10.1002/aenm.201701210 · Cited by 246
Efficiency of energy conversion for devices containing a piezoelectric component
Richards, C. D., Anderson, M. J., Bahr, D. F., & Richards, R. F. (2004) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/14/5/009 · Cited by 246
Human-Generated Power for Mobile Electronics
(2018) · Low-Power Electronics Design · doi:10.1201/9781420039559-56 · Cited by 233
A piezoelectric fibre composite based energy harvesting device for potential wearable applications
Swallow, L. M., Luo, J. K., Siores, E., Patel, I., & Dodds, D. (2008) · Smart Materials and Structures · doi:10.1088/0964-1726/17/2/025017 · Cited by 208
Powering implantable and ingestible electronics
Yang, S., Sencadas, V., You, S. S., Jia, N. Z., Srinivasan, S. S., Huang, H., Ahmed, A. E., Liang, J. Y., & Traverso, G. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202009289 · Cited by 183
Ahmed, R., Mir, F., & Banerjee, S. (2017) · Smart Materials and Structures · doi:10.1088/1361-665x/aa7bfb · Cited by 180
“In 1984, Hausler et al [93] first investigated the possibility of harvesting energy from a biological environment and then proposed an implantable physiological power system.”
BackgroundMethodInfluentialLead-free piezoelectrics: Current status and perspectives
Coondoo, I., Panwar, N., & Kholkin, A. (2013) · Journal of Advanced Dielectrics · doi:10.1142/s2010135x13300028 · Cited by 173
Acoustic energy harvesting using an electromechanical Helmholtz resonator
Liu, F., Phipps, A., Horowitz, S., Ngo, K., Cattafesta, L., Nishida, T., & Sheplak, M. (2008) · The Journal of the Acoustical Society of America · doi:10.1121/1.2839000 · Cited by 160
Miniature battery-free bioelectronics
Nair, V., Dalrymple, A. N., Yu, Z., Balakrishnan, G., Bettinger, C. J., Weber, D. J., Yang, K., & Robinson, J. T. (2023) · Science · doi:10.1126/science.abn4732 · Cited by 128
“The b phase of flexible, nontoxic PVDF fluoropolymers also exhibits a well-documented piezoelectric response ( 27 , 28 ). b -PVDF has been used to harvest mechanical energy and to power implantable bioelectronics since as early as 1984 ( 29 ).”
Method
Metadata
- Authors
- Häsler, E., Stein, L., & Harbauer, G.
- Venue
- Ferroelectrics
- Publisher
- Informa UK Limited
- Published
- 1984-10
- Volume
- 60
- Issue
- 1
- Pages
- 277-282
- ISSN
- 0015-0193 (ISSN-L)
- 1563-5112
- OpenAlex
- W2075791139
- Cited by
- 144
- References
- 0
- FWCI
- 1.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.