Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 175

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Feature extraction from ECG signals using wavelet transforms for disease diagnostics

Saxena, S. C., Kumar, V., Hamde, S. T. · 2002 · International Journal of Systems Science

Abstract

This paper deals with a modified combined wavelet transform technique that has been developed to analyse multilead electrocardiogram signals for cardiac disease diagnostics. Two wavelets have been used, i.e. a quadratic spline wavelet (QSWT) for QRS detection and the Daubechies six coefficient (DU6) wavelet for P and T detection. After detecting the fundamental electrocardiogram waves, the desired electrocardiogram parameters for disease diagnostics are extracted. The software has been validated by extensive testing using the CSE DS-3 database and the MIT/BIH database. A procedure has been evolved using electrocardiogram parameters with a point scoring system for diagnosis of cardiac diseases, namely tachycardia, bradycardia left ventricular hypertrophy, and right ventricular hypertrophy. As the diagnostic results are not yet disclosed by the CSE group, two alternate diagnostic criteria have been used to check the diagnostic authenticity of the test results. The consistency and reliability of the identified and measured parameters were confirmed when both the diagnostic criteria gave the same results

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/00207720210167159

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • A Real-Time QRS Detection Algorithm

    Pan, J., & Tompkins, W. J. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325532 · Cited by 7,855 · cited 1×

    “…variability in ECGs, QRS detection methods based on amplitude threshold, squaring or slope criteria, or AN network fail as these work on the criteria of amplitude/slope threshold or amplitude–error–detection (Pan and Tompkins 1985, Hamilton and Tompkins 1986, Trahanias 1993, Shaw and Savard 1995).”
    Method

Show all 1 references

Cited by

See all 175

Metadata

Authors
Saxena, S. C., Kumar, V., & Hamde, S. T.
Venue
International Journal of Systems Science
Published
2002-01
Volume
33
Issue
13
Pages
1073-1085
ISSN
  • 0020-7721 (ISSN-L)
  • 1464-5319
OpenAlex
W2117062476
Cited by
175
References
1
FWCI
2.28
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Feature extraction from ECG signals using wavelet transforms for disease diagnostics. https://app.cochat.ai/papers/10.1080/00207720210167159
The paper
Saxena, S. C., Kumar, V., & Hamde, S. T. (2002). Feature extraction from ECG signals using wavelet transforms for disease diagnostics. International Journal of Systems Science. https://doi.org/10.1080/00207720210167159

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.