Feature extraction from ECG signals using wavelet transforms for disease diagnostics
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
This paper deals with a modified combined wavelet transform technique that has been developed to analyse multilead electrocardiogram signals for cardiac disease diagnostics. Two wavelets have been used, i.e. a quadratic spline wavelet (QSWT) for QRS detection and the Daubechies six coefficient (DU6) wavelet for P and T detection. After detecting the fundamental electrocardiogram waves, the desired electrocardiogram parameters for disease diagnostics are extracted. The software has been validated by extensive testing using the CSE DS-3 database and the MIT/BIH database. A procedure has been evolved using electrocardiogram parameters with a point scoring system for diagnosis of cardiac diseases, namely tachycardia, bradycardia left ventricular hypertrophy, and right ventricular hypertrophy. As the diagnostic results are not yet disclosed by the CSE group, two alternate diagnostic criteria have been used to check the diagnostic authenticity of the test results. The consistency and reliability of the identified and measured parameters were confirmed when both the diagnostic criteria gave the same results
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A theory for multiresolution signal decomposition: the wavelet representation
Mallat, S. G. (1989) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.192463 · Cited by 21,372 · cited 1×
“The WT is expressed as the time-integrated product of a signal with a set of analysing basis functions and (Mallat 1989, Rioul and Vetterli 1991, Vetterli and Cormac 1992).”
BackgroundA Real-Time QRS Detection Algorithm
Pan, J., & Tompkins, W. J. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325532 · Cited by 7,855 · cited 1×
“…variability in ECGs, QRS detection methods based on amplitude threshold, squaring or slope criteria, or AN network fail as these work on the criteria of amplitude/slope threshold or amplitude–error–detection (Pan and Tompkins 1985, Hamilton and Tompkins 1986, Trahanias 1993, Shaw and Savard 1995).”
MethodChui, C. K., & Heil, C. (1992) · Computers in Physics · doi:10.1063/1.4823126 · Cited by 4,732
Wavelets and signal processing
Rioul, O., & Vetterli, M. (1991) · IEEE Signal Processing Magazine · doi:10.1109/79.91217 · Cited by 2,786 · cited 1×
“The WT is expressed as the time-integrated product of a signal with a set of analysing basis functions and (Mallat 1989, Rioul and Vetterli 1991, Vetterli and Cormac 1992).”
BackgroundWavelets and filter banks: theory and design
Vetterli, M., & Herley, C. (1992) · IEEE Transactions on Signal Processing · doi:10.1109/78.157221 · Cited by 1,690
Detection of ECG characteristic points using wavelet transforms
Li, C., Zheng, C., & Tai, C. (1995) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.362922 · Cited by 1,597
Quantitative Investigation of QRS Detection Rules Using the MIT/BIH Arrhythmia Database
Hamilton, P. S., & Tompkins, W. J. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325695 · Cited by 1,142
Estimation of QRS Complex Power Spectra for Design of a QRS Filter
Thakor, N. V., Webster, J. G., & Tompkins, W. J. (1984) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1984.325393 · Cited by 427 · cited 2×
“It is an established fact that QRS detection is taken as the basis for identification and extraction of various parameters of ECG signal (Thakor et al. 1984, Pan and Tomkins 1985, Naima and Saxena l989, Laguna et al. 1992, Xue et al. 1992, Trahanias 1993, Shaw and Javard 1995, Vijaya et al. 1997,…”
BackgroundNeural-network-based adaptive matched filtering for QRS detection
Xue, Q., Hu, Y. H., & Tompkins, W. J. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.126604 · Cited by 423 · cited 1×
“…fact that QRS detection is taken as the basis for identification and extraction of various parameters of ECG signal (Thakor et al. 1984, Pan and Tomkins 1985, Naima and Saxena l989, Laguna et al. 1992, Xue et al. 1992, Trahanias 1993, Shaw and Javard 1995, Vijaya et al. 1997, Ruha et al. 1997).”
BackgroundWavelet and wavelet packet compression of electrocardiograms
Hilton, M. L. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.568915 · Cited by 415 · cited 1×
“The use of DU6 wavelet makes the signal smoother (Hilton 1997).”
MethodRuha, A., Sallinen, S., & Nissila, S. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.554762 · Cited by 255 · cited 3×
“A detection algorithm developed by Ruha et al. (1997) is based on optimized prefiltering in conjunction with a matched filter and dual-edge threshold detection and claims a QRS detection error rate of 2.2% with record number 105 of the MIT/BIH Arrythmia database.”
BackgroundMethodInfluentialAn approach to QRS complex detection using mathematical morphology
Trahanias, P. E. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.212060 · Cited by 193
Adaptive estimation of QRS complex wave features of ECG signal by the hermite model
Laguna, P., Jané, R., Olmos, S. C., Thakor, N. V., Rix, H., & Caminal, P. (1996) · Medical & Biological Engineering & Computing · doi:10.1007/bf02637023 · Cited by 117
Computer-aided interpretation of ECG for diagnostics
Mehta, S. S., Saxena, S., & Verma, H. (1996) · International Journal of Systems Science · doi:10.1080/00207729608929188 · Cited by 42
Self-citationArtificial neural network based wave complex detection in electrocardiograms
Vijaya, G., Kumar, V., & Verma, H. (1997) · International Journal of Systems Science · doi:10.1080/00207729708929370 · Cited by 36 · cited 3×
“…fact that QRS detection is taken as the basis for identification and extraction of various parameters of ECG signal (Thakor et al. 1984, Pan and Tomkins 1985, Naima and Saxena l989, Laguna et al. 1992, Xue et al. 1992, Trahanias 1993, Shaw and Javard 1995, Vijaya et al. 1997, Ruha et al. 1997).”
BackgroundMethodInfluentialSelf-citationOn the detection of QRS variations in the ECG
Shaw, G. R., & Savard, P. (1995) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.391174 · Cited by 32 · cited 2×
“…variability in ECGs, QRS detection methods based on amplitude threshold, squaring or slope criteria, or AN network fail as these work on the criteria of amplitude/slope threshold or amplitude–error–detection (Pan and Tompkins 1985, Hamilton and Tompkins 1986, Trahanias 1993, Shaw and Savard 1995).”
Method
Cited by
ECG beat classifier designed by combined neural network model
Güler, İ., & Übeylı˙, E. D. (2005) · Pattern Recognition · doi:10.1016/j.patcog.2004.06.009 · Cited by 324
Cvetkovic, D., Übeyli, E. D., & Cosic, I. (2008) · Digital Signal Processing · doi:10.1016/j.dsp.2007.05.009 · Cited by 227
“Keywords: Feature extraction; PPG; ECG; EEG; Discrete wavelet transform; PEMF; ELF; Bioeffects”
R-peaks detection based on stationary wavelet transform
Merah, M., Abdelmalik, T. A., & Larbi, B. H. (2015) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2015.06.003 · Cited by 173
“Saxena [18] in turn, uses the detail signal d4 for QRS peak detecting, while in the work of [20,1] five levels of wavelet, d1–d5, were used with a dyadic decomposition.”
MethodU-Healthcare System: State-of-the-Art Review and Challenges
Touati, F., & Tabish, R. (2013) · Journal of Medical Systems · doi:10.1007/s10916-013-9949-0 · Cited by 166
Metadata
- Authors
- Saxena, S. C., Kumar, V., & Hamde, S. T.
- Venue
- International Journal of Systems Science
- Publisher
- Informa UK Limited
- Published
- 2002-01
- Volume
- 33
- Issue
- 13
- Pages
- 1073-1085
- ISSN
- 0020-7721 (ISSN-L)
- 1464-5319
- OpenAlex
- W2117062476
- Cited by
- 175
- References
- 16
- FWCI
- 2.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.