The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
PRESSURE ALGOMETRY IN HEALTHY SUBJECTS: INTER-EXAMINER VARIABILITY
Abstract
The purpose of this study was to estimate inter-examiner reliability of head and neck algometry. Pain perception thresholds were assessed with a mechanical pressure algometer in 21 healthy individuals. Thresholds were assessed at 13 symmetrical points on each side of the head and neck, at the deltoid muscle and at the median finger. The pressure range of the instrument proved insufficient to study the pain perception threshold on the finger, however. Two different examiners carried out one or two examinations in each subject during one day. The sequence of investigations was varied randomly. The inter-examiner reliability was found to be good, with a mean intra-class correlation coefficient (ICC) of 0.75. Intra-examiner reproducibility was excellent (mean ICC = 0.84). The mean inter-examiner coefficient of variation was 18.7%, while the mean coefficient of repeatability (CR) was 1.60 kg/cm2. In comparison, the mean intra-examiner coefficient of variation was 15% while the mean CR was 1.29 kg/cm2. Statistically significant differences between examiners were found for the frontal point (p < 0.01), while a trend towards lower thresholds in one of the two observers was seen in 10 of the 13 non-significant points. Inter-examiner reliability of side differences was excellent, with CR = 1.23 kg/cm2. In conclusion, manual algometry with a rather inexpensive mechanical device has a good to excellent inter-rater reliability. When studying patients, however, the possible bias introduced by different examiners should be taken into account, both regarding study design and data analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Cited by
2016 revisions to the 2010/2011 fibromyalgia diagnostic criteria
Wolfe, F., Clauw, D. J., Fitzcharles, M.-A., Goldenberg, D. L., Häuser, W., Katz, R. L., Mease, P. J., Russell, A. S., Russell, I. J., & Walitt, B. (2016) · Seminars in Arthritis and Rheumatism · doi:10.1016/j.semarthrit.2016.08.012 · Cited by 2,232
Gender differences in pressure pain threshold in healthy humans
Chesterton, L. S., Barlas, P., Foster, N. E., Baxter, D. G., & Wright, C. C. (2003) · Pain · doi:10.1016/s0304-3959(02)00330-5 · Cited by 460
Geber, C., Klein, T., Azad, S., Birklein, F., Gierthmühlen, J., Huge, V., Lauchart, M., Nitzsche, D., Stengel, M., Valet, M., et al. (2011) · Pain · doi:10.1016/j.pain.2010.11.013 · Cited by 327
Smidt, N., van der Windt, D. A., Assendelft, W. J., Mourits, A. J., Devillé, W. L., de Winter, A. F., & Bouter, L. M. (2002) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2002.33728 · Cited by 304
Bjordal, J. M., Lopes-Martins, R. A. B., & Iversen, V. V. (2006) · British Journal of Sports Medicine · doi:10.1136/bjsm.2005.020842 · Cited by 276
Metadata
- Authors
- Antonaci, T. S.
- Venue
- Scandinavian Journal of Rehabilitation Medicine
- Publisher
- Informa UK Limited
- Published
- 1998-04-02
- Volume
- 30
- Issue
- 1
- Pages
- 3-8
- ISSN
- 0036-5505 (ISSN-L)
- OpenAlex
- W2141622595
- Cited by
- 217
- References
- 1
- FWCI
- 3.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: PRESSURE ALGOMETRY IN HEALTHY SUBJECTS: INTER-EXAMINER VARIABILITY. https://app.cochat.ai/papers/10.1080/003655098444255
- The paper
- Antonaci, T. S. (1998). PRESSURE ALGOMETRY IN HEALTHY SUBJECTS: INTER-EXAMINER VARIABILITY. Scandinavian Journal of Rehabilitation Medicine. https://doi.org/10.1080/003655098444255
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.