PRESSURE ALGOMETRY IN HEALTHY SUBJECTS: INTER-EXAMINER VARIABILITY
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
The purpose of this study was to estimate inter-examiner reliability of head and neck algometry. Pain perception thresholds were assessed with a mechanical pressure algometer in 21 healthy individuals. Thresholds were assessed at 13 symmetrical points on each side of the head and neck, at the deltoid muscle and at the median finger. The pressure range of the instrument proved insufficient to study the pain perception threshold on the finger, however. Two different examiners carried out one or two examinations in each subject during one day. The sequence of investigations was varied randomly. The inter-examiner reliability was found to be good, with a mean intra-class correlation coefficient (ICC) of 0.75. Intra-examiner reproducibility was excellent (mean ICC = 0.84). The mean inter-examiner coefficient of variation was 18.7%, while the mean coefficient of repeatability (CR) was 1.60 kg/cm2. In comparison, the mean intra-examiner coefficient of variation was 15% while the mean CR was 1.29 kg/cm2. Statistically significant differences between examiners were found for the frontal point (p < 0.01), while a trend towards lower thresholds in one of the two observers was seen in 10 of the 13 non-significant points. Inter-examiner reliability of side differences was excellent, with CR = 1.23 kg/cm2. In conclusion, manual algometry with a rather inexpensive mechanical device has a good to excellent inter-rater reliability. When studying patients, however, the possible bias introduced by different examiners should be taken into account, both regarding study design and data analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
The Design and Analysis of Clinical Experiments
Fleiss, J. L. (1999) · Wiley eBooks · doi:10.1002/9781118032923 · Cited by 4,819
Fischer, A. A. (1987) · Pain · doi:10.1016/0304-3959(87)90089-3 · Cited by 958 · cited 2×
“Lack of significant mean side difference has even been interpreted as a sufficient measure of reliability! (11).”
BackgroundBollinger, G. K. (1975) · Cited by 440
Pressure-pain threshold in human temporal region. Evaluation of a new pressure algometer
Jensen, K., Andersen, H. Ø., Olesen, J., & Lindblom, U. (1986) · Pain · doi:10.1016/0304-3959(86)90235-6 · Cited by 425 · cited 5×
“Nevertheless, the performance of the rather inexpensive algometer used here, both in terms of inter-rater reliability and cost/benefit, seems promising as compared to the more expensive electronic device that has been used in many recent PPT studies (3, 5, 7, 15, 17, 19, 21, 22).”
BackgroundMethodResultInfluentialReliability of the pressure algometer as a measure of myofascial trigger point sensitivity
Reeves, J. L., Jaeger, B., & Graff-Radford, S. B. (1986) · Pain · doi:10.1016/0304-3959(86)90117-x · Cited by 389
Muscle tenderness and pressure pain thresholds in headache. A population study
Jensen, R., Rasmussen, B. K., Pedersen, B., & Olesen, J. (1993) · Pain · doi:10.1016/0304-3959(93)90131-8 · Cited by 313
Measurements of human pressure-pain thresholds on fingers and toes
Brennum, J., Kjeldsen, M., Jensen, K., & Jensen, T. S. (1989) · Pain · doi:10.1016/0304-3959(89)90240-6 · Cited by 296 · cited 6×
“Nevertheless, the performance of the rather inexpensive algometer used here, both in terms of inter-rater reliability and cost/benefit, seems promising as compared to the more expensive electronic device that has been used in many recent PPT studies (3, 5, 7, 15, 17, 19, 21, 22).”
BackgroundMethodResultInfluentialCephalic and extracephalic pressure pain thresholds in chronic tension-type headache
Schoenen, J., Bottin, D., Hardy, F., & Gerard, P. (1991) · Pain · doi:10.1016/0304-3959(91)90198-7 · Cited by 206 · cited 3×
“Nevertheless, the performance of the rather inexpensive algometer used here, both in terms of inter-rater reliability and cost/benefit, seems promising as compared to the more expensive electronic device that has been used in many recent PPT studies (3, 5, 7, 15, 17, 19, 21, 22).”
BackgroundMethodResultPressure pain thresholds and thermal nociceptive thresholds in chronic tension-type headache
Langemark, M., Jensen, K., Jensen, T. S., & Olesen, J. (1989) · Pain · doi:10.1016/0304-3959(89)90239-x · Cited by 205 · cited 3×
“Nevertheless, the performance of the rather inexpensive algometer used here, both in terms of inter-rater reliability and cost/benefit, seems promising as compared to the more expensive electronic device that has been used in many recent PPT studies (3, 5, 7, 15, 17, 19, 21, 22).”
BackgroundMethodResultJaeger, B., & Reeves, J. L. (1986) · Pain · doi:10.1016/0304-3959(86)90211-3 · Cited by 179 · cited 2×
“; (5) central fibres of the temporalis muscle, above the superior margin of the ear; (6) frontal muscle, 2 cm above the emergence of supraorbital branches of the trigeminal nerve; (7) vertex, 2 cm from the midline; (8) mastoid process; (9) superior insertion of the sternocleidomastoid muscle; (10) insertion of the tra…”
BackgroundTunks, E., Crook, J., Norman, G., & Kalaher, S. (1988) · Pain · doi:10.1016/0304-3959(88)90176-5 · Cited by 173 · cited 3×
“(24) reported high mean generalizability coefficient values of 0.”
BackgroundVariability of sensory threshold determination in clinical use
Fagius, J., & Wahren, L. K. (1981) · Journal of the Neurological Sciences · doi:10.1016/0022-510x(81)90056-3 · Cited by 171 · cited 2×
“; (5) central fibres of the temporalis muscle, above the superior margin of the ear; (6) frontal muscle, 2 cm above the emergence of supraorbital branches of the trigeminal nerve; (7) vertex, 2 cm from the midline; (8) mastoid process; (9) superior insertion of the sternocleidomastoid muscle; (10) insertion of the tra…”
BackgroundResultPressure Threshold Measurement for Diagnosis of Myofascial Pain and Evaluation of Treatment Results
Fischer, A. A. (1986) · Clinical Journal of Pain · doi:10.1097/00002508-198612000-00001 · Cited by 154 · cited 2×
“The coefficient of repeatability (CR) was estimated for each point as two standard deviations of the inter-individual differences (10).”
BackgroundMethodCervicogenic headache, migraine, and tension-type headache. Pressure-pain threshold measurements
Bovim, G. (1992) · Pain · doi:10.1016/0304-3959(92)90258-d · Cited by 135
The Reliability of the Pressure Algometer
Merskey, H., & Spear, F. G. (1964) · British Journal of Social and Clinical Psychology · doi:10.1111/j.2044-8260.1964.tb00415.x · Cited by 122 · cited 3×
“The Pearson correlation coefficient has been used extensively to assess inter-rater reliability (13, 18, 20, 23).”
BackgroundMethodAlgometry. Measuring pain threshold, method and characteristics in healthy subjects
Hogeweg JA, L. M. (1992) · Journal of Rehabilitation Medicine · doi:10.2340/165019779299103 · Cited by 100
Sandrini, G., Antonaci, F., Pucci, E., Bono, G., & Nappi, G. (1994) · Cephalalgia · doi:10.1046/j.1468-2982.1994.1406451.x · Cited by 95 · cited 2×
“Nevertheless, the performance of the rather inexpensive algometer used here, both in terms of inter-rater reliability and cost/benefit, seems promising as compared to the more expensive electronic device that has been used in many recent PPT studies (3, 5, 7, 15, 17, 19, 21, 22).”
BackgroundMethodEvaluation of pain threshold using a simple pressure algometer
BUCHANAN, H. M., & Midgley, J. A. (1987) · Clinical Rheumatology · doi:10.1007/bf02330587 · Cited by 93
Takala, E. (2020) · Journal of Rehabilitation Medicine · doi:10.2340/1650197790226368 · Cited by 86 · cited 3×
“The Pearson correlation coefficient has been used extensively to assess inter-rater reliability (13, 18, 20, 23).”
BackgroundMethodChung, S., Um, B.-Y., & Kim, H. (1992) · CRANIO® · doi:10.1080/08869634.1992.11677888 · Cited by 84 · cited 4×
“Inter-examiner reliability of pressure algometry has been studied previously (6, 7, 18, 20, 24), but between-examiner coefficients of variation or coefficients of repeatability have not been reported in those investigations.”
BackgroundMethodInfluential
Cited by
2016 revisions to the 2010/2011 fibromyalgia diagnostic criteria
Wolfe, F., Clauw, D. J., Fitzcharles, M.-A., Goldenberg, D. L., Häuser, W., Katz, R. L., Mease, P. J., Russell, A. S., Russell, I. J., & Walitt, B. (2016) · Seminars in Arthritis and Rheumatism · doi:10.1016/j.semarthrit.2016.08.012 · Cited by 2,232
Chesterton, L. S., Sim, J., Wright, C. C., & Foster, N. E. (2007) · The Clinical Journal of Pain · doi:10.1097/ajp.0b013e318154b6ae · Cited by 691
Gender differences in pressure pain threshold in healthy humans
Chesterton, L. S., Barlas, P., Foster, N. E., Baxter, D. G., & Wright, C. C. (2003) · Pain · doi:10.1016/s0304-3959(02)00330-5 · Cited by 460
Geber, C., Klein, T., Azad, S., Birklein, F., Gierthmühlen, J., Huge, V., Lauchart, M., Nitzsche, D., Stengel, M., Valet, M., et al. (2011) · Pain · doi:10.1016/j.pain.2010.11.013 · Cited by 327
Smidt, N., van der Windt, D. A., Assendelft, W. J., Mourits, A. J., Devillé, W. L., de Winter, A. F., & Bouter, L. M. (2002) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2002.33728 · Cited by 304
Metadata
- Authors
- Antonaci, T. S.
- Venue
- Scandinavian Journal of Rehabilitation Medicine
- Publisher
- Informa UK Limited
- Published
- 1998-04-02
- Volume
- 30
- Issue
- 1
- Pages
- 3-8
- ISSN
- 0036-5505 (ISSN-L)
- OpenAlex
- W2141622595
- Cited by
- 217
- References
- 21
- FWCI
- 3.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.