CoChat

The euglycemic hyperinsulinemic clamp examination: variability and reproducibility

L. Bokemark, A. Frödén, S. Attvall, · 2000 · Scandinavian Journal of Clinical and Laboratory Investigation
Cited by 56

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

The aim was to examine the reproducibility of the euglycemic hyperinsulinemic clamp method. From a random population sample of 60-year-old clinically healthy men, 32 subjects with varying degrees of insulin sensitivity were recruited. Conventional 2-h clamp examinations were carried out at an interval of 2 weeks. Insulin was infused intravenously (priming for 10 min and thereafter 1.0 mU/kg body wt/min). Glucose was infused concomitantly aiming at a whole blood glucose of 5 mmol/L. The glucose infusion rate (GIR) was adjusted for body weight or fat free mass (FFM), the latter measured with dual-energy X-ray absorptiometry. During the final hour of each examination (60-120 min) the mean whole blood glucose concentrations were 5.06+/-0.15 and 5.09+/-0.17 mmol/L, respectively. Of the different time intervals studied, the glucose infusion rate during the final hour (GIR60-120) showed the highest correlation and lowest coefficient of variation (GIR60-120 adjusted by FFM: r=0.70, coefficient of variation=14.7%). Adjustment of GIR for weight instead of FFM underestimated insulin sensitivity in obese men. GIR60-120 adjusted for FFM tended to increase during the second examination. The measurement error was constant across all GIR. In summary, the euglycemic hyperinsulinemic clamp method has a coefficient of variation around 15%. The glucose infusion rate should be adjusted for fat free mass.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/00365510050185010

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 56

Metadata

Authors
L. Bokemark, A. F.
Venue
Scandinavian Journal of Clinical and Laboratory Investigation
Published
2000-01
Volume
60
Issue
1
Pages
27-36
ISSN
  • 0036-5513 (ISSN-L)
  • 1502-7686
OpenAlex
W2122980223
Cited by
56
References
7
FWCI
2.12
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The euglycemic hyperinsulinemic clamp examination: variability and reproducibility. https://app.cochat.ai/papers/10.1080/00365510050185010
The paper
L. Bokemark, A. F. (2000). The euglycemic hyperinsulinemic clamp examination: variability and reproducibility. Scandinavian Journal of Clinical and Laboratory Investigation. https://doi.org/10.1080/00365510050185010

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.