The DOI matches its Crossref record.
Characterization of an enzyme-linked immunosorbent assay for soluble CD163
Abstract
We have recently identified a soluble plasma form of CD163 sCD163, the macrophage receptor for clearance of haptoglobin-haemoglobin complexes, and we have observed highly elevated levels of sCD163 in subgroups of haematological patients. In the present study, we describe the optimization and characterization of a sandwich ELISA for the determination of the concentration of sCD163 in plasma and serum. The optimal concentrations of antibodies were determined systematically and the assay was calibrated by CD163 purified from human spleen membranes. The minimum detection limit was below 6.25 microg/L. Recovery of CD163 added to plasma samples was 106%. The concentration of sCD163 in paired serum and plasma samples correlated well (r2=0.99); however, serum levels were 1.1 times higher than the plasma levels. The addition of haptoglobin-haemoglobin complexes did not influence the assay. A very high stability of sCD163 was measured in whole blood and in plasma subjected to different temperatures and after repeated freezing and thawing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
CD163 and Inflammation: Biological, Diagnostic, and Therapeutic Aspects
Etzerodt, A., & Moestrup, S. K. (2013) · Antioxidants & Redox Signaling · doi:10.1089/ars.2012.4834 · Cited by 604
Self-citationScavenger receptor CD163, a Jack-of-all-trades and potential target for cell-directed therapy
Van Gorp, H., Delputte, P. L., & Nauwynck, H. J. (2010) · Molecular Immunology · doi:10.1016/j.molimm.2010.02.008 · Cited by 357
Møller, H. J. (2012) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365513.2011.626868 · Cited by 343
Self-citationJensen, T. O., Schmidt, H., Møller, H. J., Høyer, M., Maniecki, M. B., Sjoegren, P., Christensen, I. J., & Steiniche, T. (2009) · Journal of Clinical Oncology · doi:10.1200/jco.2008.19.9919 · Cited by 299
Self-citationRosso, C., Kazankov, K., Younes, R., Esmaili, S., Marietti, M., Sacco, M., Carli, F., Gaggini, M., Salomone, F., Møller, H. J., et al. (2019) · Journal of Hepatology · doi:10.1016/j.jhep.2019.06.031 · Cited by 217
Self-citation
Metadata
- Authors
- Møller, H. J., Hald, K., & Moestrup, S. K.
- Venue
- Scandinavian Journal of Clinical and Laboratory Investigation
- Publisher
- Informa UK Limited
- Published
- 2002-01
- Volume
- 62
- Issue
- 4
- Pages
- 293-299
- ISSN
- 0036-5513 (ISSN-L)
- 1502-7686
- OpenAlex
- W2017212084
- Cited by
- 162
- References
- 0
- FWCI
- 1.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Characterization of an enzyme-linked immunosorbent assay for soluble CD163. https://app.cochat.ai/papers/10.1080/003655102760145852
- The paper
- Møller, H. J., Hald, K., & Moestrup, S. K. (2002). Characterization of an enzyme-linked immunosorbent assay for soluble CD163. Scandinavian Journal of Clinical and Laboratory Investigation. https://doi.org/10.1080/003655102760145852
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.