CoChat

A multicentre study of reference intervals for haemoglobin, basic blood cell counts and erythrocyte indices in the adult population of the Nordic countries

Nordin, G., Mårtensson, A., Swolin, B., Sandberg, S., Christensen, N. J., Thorsteinsson, V., Franzson, L., Kairisto, V., Savolainen, E.‐R. · 2004 · Scandinavian Journal of Clinical and Laboratory Investigation
Cited by 98

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Eight haematological quantities were measured in EDTA anticoagulated venous blood specimens collected from 1826 healthy male and female individuals between 18 and 90 years of age in the Nordic countries (Denmark, Finland, Iceland, Norway and Sweden). The samples, collected between November 1999 and November 2001 as part of the Nordic Reference Interval Project (NORIP), were analysed on 12 different types of modern automated haematology instruments currently in use among the 60 laboratories participating in the study. Non-parametric reference intervals (between 2.5 and 97.5 percentiles) have been calculated for B-Haemoglobin (females 117-153 g/L, males 134-170 g/L), B-Erythrocytes (females 3.94-5.16 x 10(12)/L, males 4.25-5.71 x 10(12)/L), B-EVF (females 0.348-0.459, males 0.395-0.500), B-MCV (82-98 fL), Erc-MCH (27.1-33.3 pg), Erc-MCHC (317-357 g/L), B-Trc (females 165-387 x 10(9)/L, males 145 x 348 x 10(9)/L) and B-Lkc (3.5-8.8 x 10(9)/L). Partitioning of data according to age and gender was done according to a standardized procedure. For most variables the calculated reference intervals corresponded well with older and less well-defined reference intervals. The mean concentration of B-Haemoglobin increased by 0.08 g/L per year of age in women, and decreased by 0.1 g/L per year of age in men. B-Haemoglobin increased with body mass index in both men and women. Smoking increased the mean of B-Lkc by 1.1 x 10(9)/L and regular use of alcohol increased the mean of B-MCV by 0.8 fL. The influence of these factors was small overall and did not promote specific reference intervals.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/00365510410002797

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 98

Metadata

Authors
Nordin, G., Mårtensson, A., Swolin, B., Sandberg, S., Christensen, N. J., Thorsteinsson, V., Franzson, L., Kairisto, V., & Savolainen, E. ‐.
Venue
Scandinavian Journal of Clinical and Laboratory Investigation
Published
2004-06
Volume
64
Issue
4
Pages
385-398
ISSN
  • 0036-5513 (ISSN-L)
  • 1502-7686
OpenAlex
W2091388762
Cited by
98
References
1
FWCI
1.71
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A multicentre study of reference intervals for haemoglobin, basic blood cell counts and erythrocyte indices in the adult population of the Nordic countries. https://app.cochat.ai/papers/10.1080/00365510410002797
The paper
Nordin, G., Mårtensson, A., Swolin, B., Sandberg, S., Christensen, N. J., Thorsteinsson, V., Franzson, L., Kairisto, V., & Savolainen, E. ‐. (2004). A multicentre study of reference intervals for haemoglobin, basic blood cell counts and erythrocyte indices in the adult population of the Nordic countries. Scandinavian Journal of Clinical and Laboratory Investigation. https://doi.org/10.1080/00365510410002797

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.