The DOI matches its Crossref record.
The Nordic Reference Interval Project 2000: recommended reference intervals for 25 common biochemical properties
Abstract
Each of 102 Nordic routine clinical biochemistry laboratories collected blood samples from at least 25 healthy reference individuals evenly distributed for gender and age, and analysed 25 of the most commonly requested serum/plasma components from each reference individual. A reference material (control) consisting of a fresh frozen liquid pool of serum with values traceable to reference methods (used as the project "calibrator" for non-enzymes to correct reference values) was analysed together with other serum pool controls in the same series as the project samples. Analytical data, method data and data describing the reference individuals were submitted to a central database for evaluation and calculation of reference intervals intended for common use in the Nordic countries. In parallel to the main project, measurements of commonly requested haematology properties on EDTA samples were also carried out, mainly by laboratories in Finland and Sweden. Aliquots from reference samples were submitted to storage in a central bio-bank for future establishment of reference intervals for other properties. The 25 components were, in alphabetical order: alanine transaminase, albumin, alkaline phosphatase, amylase, amylase pancreatic, aspartate transaminase, bilirubins, calcium, carbamide, cholesterol, creatine kinase, creatininium, gamma-glutamyltransferase, glucose, HDL-cholesterol, iron, iron binding capacity, lactate dehydrogenase, magnesium, phosphate, potassium, protein, sodium, triglyceride and urate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Establishing Reference Intervals for Clinical Laboratory Test Results: Is There a Better Way?
Katayev, A., Balciza, C., & Seccombe, D. W. (2010) · American Journal of Clinical Pathology · doi:10.1309/ajcpn5bmtsf1cdyp · Cited by 280
Peak Oxygen Uptake and Cardiovascular Risk Factors in 4631 Healthy Women and Men
ASPENES, S. T., NILSEN, T. I. L., SKAUG, E.-A., BERTHEUSSEN, G. F., ELLINGSEN, Ø., VATTEN, L., & WISLØFF, U. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31820ca81c · Cited by 278
Reference intervals: current status, recent developments and future considerations
Ozarda, Y. (2016) · Biochemia Medica · doi:10.11613/bm.2016.001 · Cited by 264
Incidence and determinants of hyperkalemia and hypokalemia in a large healthcare system
Nilsson, E., Gasparini, A., Ärnlöv, J., Xu, H., Henriksson, K. M., Coresh, J., Grams, M. E., & Carrero, J. J. (2017) · International Journal of Cardiology · doi:10.1016/j.ijcard.2017.07.035 · Cited by 211
Reference intervals: the way forward
Ceriotti, F., Hinzmann, R., & Panteghini, M. (2009) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1258/acb.2008.008170 · Cited by 199
Metadata
- Authors
- Rustad, P., Felding, P., Franzson, L., Kairisto, V., Lahti, A., Mårtensson, A., Petersen, P. H., Simonsson, P., Steensland, H., & Uldall, A.
- Venue
- Scandinavian Journal of Clinical and Laboratory Investigation
- Publisher
- Informa UK Limited
- Published
- 2004-06
- Volume
- 64
- Issue
- 4
- Pages
- 271-284
- ISSN
- 0036-5513 (ISSN-L)
- 1502-7686
- OpenAlex
- W2003239940
- Cited by
- 404
- References
- 0
- FWCI
- 7.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Nordic Reference Interval Project 2000: recommended reference intervals for 25 common biochemical properties. https://app.cochat.ai/papers/10.1080/00365510410006324
- The paper
- Rustad, P., Felding, P., Franzson, L., Kairisto, V., Lahti, A., Mårtensson, A., Petersen, P. H., Simonsson, P., Steensland, H., & Uldall, A. (2004). The Nordic Reference Interval Project 2000: recommended reference intervals for 25 common biochemical properties. Scandinavian Journal of Clinical and Laboratory Investigation. https://doi.org/10.1080/00365510410006324
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.