CoChat

Consequences Of Bias and Imprecision in Measurements of Glucose and Hba1c for the Diagnosis and Prognosis of Diabetes Mellitus

Petersen, Per Hyltoft, Jørgensen, Lone G. M., Brandslund, Ivan, De Fine Olivarius, Niels, Stahl, Marta · 2005 · Scandinavian Journal of Clinical and Laboratory Investigation
Cited by 51

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

AIM: To investigate the effect of composite analytical bias and imprecision in the measurements of fasting plasma-glucose (fPG) for diagnosis of diabetes mellitus and estimation of risk of development and progression of retinopathy using measurements of Haemoglobin A1C (HbA1C%). MATERIALS AND METHODS: Data on biological within-subject variation for fPG (5.7% and 4.9%) and HbA1C% (1.9%) from literature and data on fPG for a 'low-risk' population (regarding diabetes) from own investigations (ln-values of mean=1.6781 approximately geometric mean population=5.36 mmol/L and standard deviation=0.0891 approximately CV population=8.9%). Further, guidelines for diagnosis of diabetes (two consecutive measurements of fPG above 7.0 mmol/L) were obtained from literature as also the risk of development of and progression of retinopathy using measurements of HbA1C (a change in risk of 44% for a change in HbA1C% of 10%). It was assumed that each individual had values which over a short time had a Gaussian distribution about a biological set-point. Calculations of the effect of analytical bias and imprecision were performed by linear addition of bias and squared addition of imprecision to the squared error-free biological distribution. Composite variations of bias and imprecision were obtained by varying assumed imprecision and calculating the maximum acceptable bias for the stated situation. RESULTS: Two diagnostic examples are described for fPG and one for risk related to HbA1C%. Firstly, the risk of diabetes as a function of set-point and bias and imprecision was investigated, using functions where the probability of two measurements above 7.0 mmol/L was plotted against biological set-points, resulting in a S-shaped curve with a 25% probability for a set-point equal to 7.0 mmol/L. Here, a maximum 5% probability of classifying an individual with a set-point of 6.4 mmol/L (upper reference limit for the 'low-risk' population) as diabetic was used to calculate the analytical quality specifications. Comparably, the 5% probability of misclassifying a diabetic with fPG of 8.0 mmol/L was investigated, and both specifications were illustrated in an imprecision-bias plot. Secondly, the percentage of 'low-risk' individuals which would be falsely diagnosed as diabetic was calculated, and this percentage was plotted as a function of bias for different assumed values of imprecision. Thirdly, the confidence intervals for a certain risk-difference for HbA1C% of 5% or 10% was used to draw an imprecision-bias plot for different assumed changes and probabilities. DISCUSSION: Analytical quality taking the demands for bias and imprecision in account are obtainable in laboratories, but may be questionable for use of capillary blood and POCT instruments with considerable consequences for the number of individuals classified as diabetics, and thereby for the economy etc. CONCLUSION: For clinical settings, with so clear recommendations and descriptions of risk curves as in diabetes, it is relatively easy to estimate the analytical quality specifications according to the highest level of the model hierarchy, when relevant probabilities for the events are assumed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/00365510500236135

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 51

Metadata

Authors
Petersen, P. H., Jørgensen, L. G. M., Brandslund, I., De Fine Olivarius, N., & Stahl, M.
Venue
Scandinavian Journal of Clinical and Laboratory Investigation
Published
2005-01
Volume
65
Issue
sup240
Pages
51-60
ISSN
  • 0036-5513 (ISSN-L)
  • 1502-7686
OpenAlex
W2029698668
Cited by
51
References
2
FWCI
0.55
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Consequences Of Bias and Imprecision in Measurements of Glucose and Hba1c for the Diagnosis and Prognosis of Diabetes Mellitus. https://app.cochat.ai/papers/10.1080/00365510500236135
The paper
Petersen, P. H., Jørgensen, L. G. M., Brandslund, I., De Fine Olivarius, N., & Stahl, M. (2005). Consequences Of Bias and Imprecision in Measurements of Glucose and Hba1c for the Diagnosis and Prognosis of Diabetes Mellitus. Scandinavian Journal of Clinical and Laboratory Investigation. https://doi.org/10.1080/00365510500236135

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.