Cited by 73Clinical Laboratory Practices and Quality ControlScientific Measurement and Uncertainty EvaluationReliability and Agreement in Measurement

Bias in clinical chemistry

Open access
Theodorsson, Elvar, Magnusson, Bertil, Leito, Ivo·2014·Bioanalysis

Abstract

Clinical chemistry uses automated measurement techniques and medical knowledge in the interest of patients and healthy subjects. Automation has reduced repeatability and day-to-day variation considerably. Bias has been reduced to a lesser extent by reference measurement systems. It is vital to minimize clinically important bias, in particular bias within conglomerates of laboratories that measure samples from the same patients. Small and variable bias components will over time show random error properties and conventional random-error based methods for calculating measurement uncertainty can then be applied. The present overview of bias presents the general principles of error and uncertainty concepts, terminology and analysis, and suggests methods to minimize bias and measurement uncertainty in the interest of healthcare.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.4155/bio.14.249

Cites

92 of 92 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Even after the advent of accreditation standards ISO 17025 and 15189 demanding uncertainty calculations, top-down variance component analysis used in error/frequentist statistics are commonly used for uncertainty estimation using internal quality control samples.

    “Even after the advent of accreditation standards ISO 17025 and 15189 demanding uncertainty calculations, top-down variance component analysis used in error/frequentist statistics are commonly used for uncertainty estimation using internal quality control samples.75,76”

    From Uncertainty in Measurement and Total Error (2017) · cites this paper as [76]

    Split into 2 atoms — 0 confirmed, 2 partially supported, 0 disputed, 0 misattributed, 0 unverifiable. Expand the claim to see per-atom verdicts.

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

1 of the 93 references couldn’t be matched to a known paper.

Research works printed but not linked: 3

  1. [2]2. Compendium of chemical terminology : IUPAC recommendations. (2nd). Blackwell Science, Oxford England ; Malden, MA, USA. (1997). 2. Clsi: EP09-A3 Measurement Procedure Comparison and Bias Estimation Using Patient Samples; Approved Guideline - Third Edition . (2013).
  2. [49]49. Ellison SLR, Farrant TJ, Barwick V, Royal Society of Chemistry (Great Britain): Practical statistics for the analytical scientist : a bench guide. (2nd). RSC Publishing, Cambridge, UK. (2009).
  3. [80]80. Ellison SLR, Barwick VJ: Estimating measurement uncertainty: reconciliation using a cause and effect approach . Accredit Qual Assur 3(3), 101-105 (1998).

Cited by

Sorted by citations

Authors
Theodorsson, E., Magnusson, B., & Leito, I.
Affiliations
  • Linköping University (SE)
  • RISE Research Institutes of Sweden (SE)
  • University of Tartu (EE)
Venue
Bioanalysis
Published
2014-11
Volume
6
Issue
21
Pages
2855-2875
ISSN
  • 1757-6180 (ISSN-L)
  • 1757-6199
OpenAlex
W2037120565
Cited by
73
References
93
Citations by year
2026: 3 · 2025: 4 · 2024: 7 · 2023: 6 · 2022: 1 · 2021: 9 · 2020: 7 · 2019: 6 · 2018: 11 · 2017: 8 · 2016: 8 · 2015: 2 · 2014: 1
FWCI
0.74
Type
journal article
Language
en
Open access
Licence
other-oa
Locations
  • Bioanalysis (publishedVersion)
  • PubMed (publishedVersion)
  • KTH Publication Database DiVA (KTH Royal Institute of Technology) (submittedVersion, other-oa)
Topics
  • Health Sciences › Medicine › Physiology › Clinical Laboratory Practices and Quality Control
  • Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Scientific Measurement and Uncertainty Evaluation
  • Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
Keywords
measurement bias, clinical chemistry, measurement uncertainty, random error, repeatability, day-to-day variability, reference measurement system, laboratory network, bias mitigation
MeSH terms
Automation, Humans, Laboratories, Quality Control, Reproducibility of Results, Clinical Chemistry Tests, Uncertainty

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review