Determination of the production rate and non‐renal clearance of cystatin C and estimation of the glomerular filtration rate from the serum concentration of cystatin C in humans
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
Cystatin C has been proposed as an endogenous marker for measuring glomerular filtration rate (GFR) and is regarded as being equivalent to or better than creatinine. However, there are no published data on the production rate (Cys(pr)) or on the non-renal clearance of cystatin C (CL(nr)) in humans, which are essential parameters for GFR calculation. GFR was determined by measuring the plasma clearance of iohexol. Cystatin C, creatinine, urea and albumin were determined on the same serum samples as iohexol; 381 patients with a GFR range of 12-151 ml/min/1.73 m2, and 70 patients on haemodialysis were evaluated. Renal clearance of cystatin C (CLr) equals GFR * S (the sieving coefficient). Plasma clearance (CL) = CLr + CLnr. The relationship between Cys(pr) and the elimination rate (CL * serum-cystatin C) can be expressed as Cys(pr) = (S * GFR+CLnr) * serum-cystatin C. Assuming that the unknown values of Cys(pr) and CLnr are independent of GFR, the equation can be solved from GFR (iohexol clearance) and serum cystatin C (s-Cys) patient data. For S=1, we found Cys(pr) = 0.124 +/- 0.023 mg/min/1.73 m2 and Cl(nr)=22.3 ml/min/1.73 m2. For S = 0.94, found in rats, the values will be Cys(pr) = 0.117 mg/min/1.73 m2 and Cl(nr) = 21 ml/min/1.73 m2 and S-Cys in 70 patients on chronic haemodialysis was found to be 5.74 +/- 1.15 mg/l, in agreement with a calculated value of 5.56 mg/l (s-Cys=124/22.3) for GFR=zero. The mean value of the calculated Cl(nr) for the 70 patients was 22.7 +/- 6.6 ml/min/1.73 m2, which confirms the calculated level and indicates its biological variation. We thus propose the following formula for calculating GFR using the values found for CLnr and Cys(pr) in this study: GFR=124/s - Cys - 22.3 ml/min/1.73 m2, where serum cystatin C concentration is given as mg/l.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Prediction of Creatinine Clearance from Serum Creatinine
Cockcroft, D. W., & Gault, H. (1976) · Nephron · doi:10.1159/000180580 · Cited by 15,309 · cited 3×
“The correlation coefficients between GFR determined with plasma clearance of iohexol and our cystatin C formula (Equation 3), creatinine clearance according to Jelliffe [7], Cockcroft & Gault [8] and MDRD [9] were found to be as follows: 0.”
MethodA formula to estimate the approximate surface area if height and weight be known. 1916.
Bois, D. D., & Bois, E. F. D. (1989) · PubMed · Cited by 5,706
Du BOIS, D. (1916) · Archives of Internal Medicine · doi:10.1001/archinte.1916.00080130010002 · Cited by 4,342
Limitations of creatinine as a filtration marker in glomerulopathic patients
Shemesh, O., Golbetz, H., Kriss, J. P., & Myers, B. D. (1985) · Kidney International · doi:10.1038/ki.1985.205 · Cited by 1,227 · cited 1×
“However, creatinine clearance is an unreliable measure of GFR in both healthy [6] and sick persons [39] and may vary up to 40% owing to varying tubular secretion and reabsorption of creatinine [6].”
BackgroundKnight, E. L., Verhave, J. C., Spiegelman, D., Hillege, H. L., De Zeeuw, D., Curhan, G. C., & De Jong, P. E. (2004) · Kidney International · doi:10.1111/j.1523-1755.2004.00517.x · Cited by 1,039 · cited 2×
“[25] report that older age, male gender, greater weight and height, cigarette smoking and higher CRP levels increase the production and/or catabolism of cystatin C.”
BackgroundA Simple Method for the Determination of Glomerular Filtration Rate
Bröchner-Mortensen, J. (1972) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365517209084290 · Cited by 886
Newman, D. J., Thakkar, H., Edwards, R. G., Wilkie, M., White, T., Grubb, A. O., & Price, C. P. (1995) · Kidney International · doi:10.1038/ki.1995.40 · Cited by 650 · cited 1×
“The correlation coefficient of the relationship between reciprocal serum cystatin C and GFR in this study is similar to that described in other studies [12,13,19,20].”
ResultColl, E., Botey, A., Alvarez, L., Poch, E., Quintó, L., Saurina, A., Vera, M., Piera, C., & Darnell, A. (2000) · American Journal of Kidney Diseases · doi:10.1053/ajkd.2000.8237 · Cited by 642
Structure and expression of the human cystatin C gene
Abrahamson, M., Olafsson, I., Palsdottir, A., Ulvsbäck, M., Lundwall, Å., Jensson, O., & Grubb, A. (1990) · Biochemical Journal · doi:10.1042/bj2680287 · Cited by 612 · cited 1×
“It is produced at a constant rate by all nucleated cells, almost freely filtered by the glomeruli and catabolised by the proximal tubules [15,16].”
BackgroundCreatinine Clearance: Bedside Estimate
JELLIFFE, R. W. (1973) · Annals of Internal Medicine · doi:10.7326/0003-4819-79-4-604 · Cited by 489
Renal handling of radiolabelled human cystatin C in the rat
Tenstad, O., Roald, A. B., Grubb, A., & Aukland, K. (1996) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365519609088795 · Cited by 456 · cited 4×
“This value corresponds to that found in healthy rats where a non-renal plasma clearance of 15¡3% of the total clearance was found [26].”
BackgroundResultInfluentialCalculation of glomerular filtration rate expressed in mL/min from plasma cystatin C values in mg/L
Larsson, A., Malm, J., Grubb, A., & Hansson, L.-O. (2004) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365510410003723 · Cited by 407 · cited 2×
“have suggested two formulae, dependent on the method used to determine cystatin C [46].”
MethodMussap, M., Vestra, M. D., Fioretto, P., Saller, A., Varagnolo, M., Nosadini, R., & Plebani, M. (2002) · Kidney International · doi:10.1046/j.1523-1755.2002.00253.x · Cited by 292 · cited 2×
“Many investigators have found that the measurement of serum cystatin is particularly useful for detecting a slight decrease in renal function [19,36,37].”
BackgroundResultNewman, D. J. (2002) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1258/0004563021901847 · Cited by 215
Tan, G. D., Lewis, A. V., James, T. J., Altmann, P., Taylor, R. P., & Lévy, J. (2002) · Diabetes Care · doi:10.2337/diacare.25.11.2004 · Cited by 154
Noortgate, N. J. V. D., Janssens, W. H., Delanghe, J., Afschrift, M. B., & Lameire, N. H. (2002) · Journal of the American Geriatrics Society · doi:10.1046/j.1532-5415.2002.50317.x · Cited by 126
Changes in Plasma Cystatin C after Renal Transplantation and Acute Rejection in Adults
Bricon, T. L., Thervet, É., Benlakehal, M., Bousquet, B., Legendre, C. M., & Erlich, D. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.12.2243 · Cited by 109 · cited 1×
“This finding that serum cystatin C detects changes in GFR earlier than serum creatinine has been shown in previous studies, especially in those involving renal transplantation patients [18,41,42].”
ResultPlasmatic cystatin C for the estimation of glomerular filtration rate in intensive care units
Delanaye, P., Lambermont, B. C., Chapelle, J.-P., GIELEN, J. E., Gérard, P., & Rorive, G. L. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2189-5 · Cited by 94 · cited 1×
“It has been shown to be advantageous for the early detection of both radiocontrast-induced nephrotoxicity [43] and acute onset kidney failure in intensive care patients [44].”
BackgroundChristensson, A. G., Ekberg, J., GRUBB, A. O., Ekberg, H., Lindström, V., & Lilja, H. G. (2003) · Nephron Physiology · doi:10.1159/000071287 · Cited by 87 · cited 1×
“This finding that serum cystatin C detects changes in GFR earlier than serum creatinine has been shown in previous studies, especially in those involving renal transplantation patients [18,41,42].”
ResultComparison of cystatin C versus creatinine for detection of mild renal failure.
Chantrel, F., Agin, A., Offner, M., Koehl, C., Moulin, B., & Hannedouche, T. (2000) · PubMed · Cited by 49
Cystatin C and creatinine after successful kidney transplantation in children.
Bökenkamp, A., OZDEN, N., Dieterich, C., Schumann, G., Ehrich, J. H. H., & Brodehl, J. (1999) · PubMed · Cited by 47
Cited by
KDIGO 2024 clinical practice guideline for the evaluation and management of chronic kidney disease
Stevens, P. E., Ahmed, S. B., Carrero, J. J., Foster, B., Francis, A., Hall, R. K., Herrington, W. G., Hill, G., Inker, L. A., Kazancıoğlu, R., et al. (2024) · Kidney International · doi:10.1016/j.kint.2023.10.018 · Cited by 8,530
Assessing Kidney Function — Measured and Estimated Glomerular Filtration Rate
Stevens, L. A., Coresh, J., Greene, T., & Levey, A. S. (2006) · New England Journal of Medicine · doi:10.1056/nejmra054415 · Cited by 2,952
Stevens, L. A., Coresh, J., Schmid, C. H., Feldman, H. I., Froissart, M., Kusek, J., Rossert, J., Van Lente, F., Bruce, R. D., Zhang, Y. (., et al. (2008) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2007.11.018 · Cited by 1,037
on behalf of the FIELD Study investigators, Davis, T. M. E., Ting, R., Best, J. D., Donoghoe, M. W., Drury, P. L., Sullivan, D. R., Jenkins, A. J., O’Connell, R. L., Whiting, M. J., et al. (2011) · Diabetologia · doi:10.1007/s00125-010-1951-1 · Cited by 403
Grubb, A., Horio, M., Hansson, L.-O., Björk, J., Nyman, U., Flodin, M., Larsson, A., Bökenkamp, A., Yasuda, Y., Blufpand, H., et al. (2014) · Clinical Chemistry · doi:10.1373/clinchem.2013.220707 · Cited by 324
Self-citation
Metadata
- Authors
- Sjöström, P., Tidman, M., & Jones, I.
- Venue
- Scandinavian Journal of Clinical and Laboratory Investigation
- Publisher
- Informa UK Limited
- Published
- 2005-04
- Volume
- 65
- Issue
- 2
- Pages
- 111-124
- ISSN
- 0036-5513 (ISSN-L)
- 1502-7686
- OpenAlex
- W1990936436
- Cited by
- 197
- References
- 21
- FWCI
- 8.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.