CoChat

Determination of the production rate and non‐renal clearance of cystatin C and estimation of the glomerular filtration rate from the serum concentration of cystatin C in humans

Sjöström, P., Tidman, M., Jones, I. · 2005 · Scandinavian Journal of Clinical and Laboratory Investigation
Cited by 197

The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.

Abstract

Cystatin C has been proposed as an endogenous marker for measuring glomerular filtration rate (GFR) and is regarded as being equivalent to or better than creatinine. However, there are no published data on the production rate (Cys(pr)) or on the non-renal clearance of cystatin C (CL(nr)) in humans, which are essential parameters for GFR calculation. GFR was determined by measuring the plasma clearance of iohexol. Cystatin C, creatinine, urea and albumin were determined on the same serum samples as iohexol; 381 patients with a GFR range of 12-151 ml/min/1.73 m2, and 70 patients on haemodialysis were evaluated. Renal clearance of cystatin C (CLr) equals GFR * S (the sieving coefficient). Plasma clearance (CL) = CLr + CLnr. The relationship between Cys(pr) and the elimination rate (CL * serum-cystatin C) can be expressed as Cys(pr) = (S * GFR+CLnr) * serum-cystatin C. Assuming that the unknown values of Cys(pr) and CLnr are independent of GFR, the equation can be solved from GFR (iohexol clearance) and serum cystatin C (s-Cys) patient data. For S=1, we found Cys(pr) = 0.124 +/- 0.023 mg/min/1.73 m2 and Cl(nr)=22.3 ml/min/1.73 m2. For S = 0.94, found in rats, the values will be Cys(pr) = 0.117 mg/min/1.73 m2 and Cl(nr) = 21 ml/min/1.73 m2 and S-Cys in 70 patients on chronic haemodialysis was found to be 5.74 +/- 1.15 mg/l, in agreement with a calculated value of 5.56 mg/l (s-Cys=124/22.3) for GFR=zero. The mean value of the calculated Cl(nr) for the 70 patients was 22.7 +/- 6.6 ml/min/1.73 m2, which confirms the calculated level and indicates its biological variation. We thus propose the following formula for calculating GFR using the values found for CLnr and Cys(pr) in this study: GFR=124/s - Cys - 22.3 ml/min/1.73 m2, where serum cystatin C concentration is given as mg/l.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/00365510510013523

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 197

Metadata

Authors
Sjöström, P., Tidman, M., & Jones, I.
Venue
Scandinavian Journal of Clinical and Laboratory Investigation
Published
2005-04
Volume
65
Issue
2
Pages
111-124
ISSN
  • 0036-5513 (ISSN-L)
  • 1502-7686
OpenAlex
W1990936436
Cited by
197
References
21
FWCI
8.43
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.