The DOI matches its Crossref record.
Renal handling of radiolabelled human cystatin C in the rat
Abstract
Serum cystatin C concentration correlates negatively with glomerular filtration rate as well as or better than that of serum creatinine, suggesting a constant formation, and elimination from extracellular fluid mainly by glomerular filtration. It is not known, however, how well the renal plasma clearance of this 13-kDa basic polypeptide matches the glomerular filtration rate. This was investigated in rats during control conditions and after reduced renal perfusion pressure. 125I-cystatin C and an indicator for glomerular filtration (51Cr-EDTA or 131I-aprotinin) were injected intravenously. The renal accumulation and urinary excretion of the tracers were recorded in periods of 2.5 to 20.0 min. The renal plasma clearance of 125I-cystatin C (Ccy) based on the renal content of 125I correlated well with the glomerular filtration rate (CCr-EDTA) in periods up to 6 min; i.e. Ccy = 0.94 x CCr-EDTA, r = 0.99. Less than 0.5% of the filtered amount appeared in the urine. During more prolonged periods, Ccy increasingly underestimated glomerular filtration rate, reaching about 0.4 x CCr-EDTA in a 20-min period. Free 125I relative to total plasma 125I activity increased from about 2% at 5 min to about 70% at 20 min. In nephrectomized rats, free 125I accumulated in plasma at a slower rate, accounting for about 15% of the total activity 20 min after injection of 125I-cystatin C. We conclude that cystatin C is (a) mainly removed from the extracellular fluid by the kidneys, (b) practically freely filtered in the glomeruli, and (c) completely absorbed and rapidly broken down by the proximal tubular cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cystatin C as a marker of GFR—history, indications, and future research
Filler, G., Bökenkamp, A., Hofmann, W., Le Bricon, T., Martínez-Brú, C., & Grubb, A. (2005) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2004.09.025 · Cited by 734
Self-citationBiochemistry and Clinical Role of Human Cystatin C
Mussap, M., & Plebani, M. (2004) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408360490504934 · Cited by 313
Vinge, E., Lindergård, B., Nilsson–Ehle, P., & Grubb, A. (1999) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365519950185076 · Cited by 265
Self-citationBökenkamp, A., Domanetzki, M., Zinck, R., Schumann, G., Byrd, D., & Brodehl, J. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.10.1866 · Cited by 123
Metadata
- Authors
- Tenstad, O., Roald, A. B., Grubb, A., & Aukland, K.
- Venue
- Scandinavian Journal of Clinical and Laboratory Investigation
- Publisher
- Informa UK Limited
- Published
- 1996-01
- Volume
- 56
- Issue
- 5
- Pages
- 409-414
- ISSN
- 0036-5513 (ISSN-L)
- 1502-7686
- OpenAlex
- W1985572290
- Cited by
- 456
- References
- 0
- FWCI
- 4.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Renal handling of radiolabelled human cystatin C in the rat. https://app.cochat.ai/papers/10.3109/00365519609088795
- The paper
- Tenstad, O., Roald, A. B., Grubb, A., & Aukland, K. (1996). Renal handling of radiolabelled human cystatin C in the rat. Scandinavian Journal of Clinical and Laboratory Investigation. https://doi.org/10.3109/00365519609088795
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.