Colloid osmotic pressure of human subcutaneous interstitial fluid sampled by nylon wicks: Evaluation of the method
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Interstitial fluid was collected from human subcutaneous tissue by implantation of multifilamentous nylon wicks on the side of thorax. The skin was anaesthetized by a small injection of lidocaine. Direct measurement of colloid osmotic pressure in a control group of 20 healthy volunteers gave a mean of 15.8 (SD 2.3) mmHg in wick fluid and 26.9 (SD 4.1) mmHg in serum samples. Standard deviation of the method for wick fluid samples was 1.2 mmHg. Significant blood contamination occurred in less than 20% of the wicks. Fluid content in wicks varied within narrow limits independent of its colloid osmotic pressure. The dynamics of wick fluid protein uptake was studied by uptake of 131I albumin from plasma, and by measurement of colloid osmotic pressure after 30, 60, 120 and 180 min of implantation. The results showed an initial rapid uptake from plasma of a major part of the wick fluid proteins within 30 min. After 120 min wick fluid colloid osmotic pressure reached the same level whether the wicks were 'primed' with serum proteins or not. Altogether these observations support the view that wick fluid reflects interstitial tissue fluid with respect to colloid osmotic pressure when the wicks are implanted for 60 min.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Twenty‐Four Hour Variation in Flow and Composition of Leg Lymph in Normal Men
Engeset, A., Olszewski, W., Jæger, P. M., Sokolowski, J., & Theodorsen, L. (1977) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1977.tb10364.x · Cited by 78
Cited by
Opportunities and challenges in the diagnostic utility of dermal interstitial fluid
Friedel, M., Thompson, I. A. P., Kasting, G., Polsky, R., Cunningham, D., Soh, H. T., & Heikenfeld, J. (2023) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00998-9 · Cited by 360
Transcapillary fluid dynamics during ovarian stimulation for in vitro fertilization
Tollan, A., Holst, N., Forsdahl, F., Fadnes, H. O., Øian, P., & Maltau, J. M. (1990) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(90)90428-a · Cited by 86
Transcapillary fluid balance in pre‐eclampsia
ØIAN, P., MALTAU, J. M., NODDELAND, H., & FADNES, H. O. (1986) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1986.tb07899.x · Cited by 52
Self-citationTranscapillary fluid dynamics during the menstrual cycle
Øian, P., Tollan, A., Fadnes, H. O., Noddeland, H., & Maltau, J. M. (1987) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(87)90364-4 · Cited by 54
Self-citationFauchald, P., Norseth, J., & Jervell, J. (1985) · Diabetologia · doi:10.1007/bf00271683 · Cited by 47
Metadata
- Authors
- Noddeland, H.
- Venue
- Scandinavian Journal of Clinical & Laboratory Investigation
- Publisher
- Informa UK Limited
- Published
- 1982-01
- Volume
- 42
- Issue
- 2
- Pages
- 123-130
- ISSN
- 0036-5513 (ISSN-L)
- 1502-7686
- OpenAlex
- W2059235965
- Cited by
- 53
- References
- 1
- FWCI
- 2.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Colloid osmotic pressure of human subcutaneous interstitial fluid sampled by nylon wicks: Evaluation of the method. https://app.cochat.ai/papers/10.1080/00365518209168062
- The paper
- Noddeland, H. (1982). Colloid osmotic pressure of human subcutaneous interstitial fluid sampled by nylon wicks: Evaluation of the method. Scandinavian Journal of Clinical & Laboratory Investigation. https://doi.org/10.1080/00365518209168062
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.