CoChat

A sensitive ELISA for von Willebrand factor (vWf:Ag)

J. Ingerslev · 1987 · Scandinavian Journal of Clinical and Laboratory Investigation
Cited by 124

The DOI matches its OpenAlex record.

Abstract

A sensitive and precise enzyme-linked immunosorbent assay for the measurement of the von Willebrand factor (new nomenclature:vWf:Ag, previous name: F VIII:RAg) of plasma and factor VIII concentrates was constructed using a microtitre plate based sandwich technique. The coating antibody extracted vWf:Ag from standard and test material. Bound fraction was detected by a F(ab')2 peroxidase conjugate of the same antibody as used for coating. The sensitivity limit of the assay was 0.004 IU/ml, at least 10 times lower than the electro-immunoassay (EIA) using the same antibody, and better than any previously reported polyclonal ELISA for vWf:Ag. Imprecision between runs was 5.1% (CV%) at the 0.50 IU/ml level. Plasma from 30 healthy people gave 1.02 +/- 0.25 IU/ml (mean +/- 1SD) in the ELISA assay and 0.99 +/- 0.30 IU/ml (mean +/- 1SD) using electro-immunoassay (EIA) with a correlation coefficient of 0.967. Two cases of homozygous recessive von Willebrand's disease revealed vWf:Ag values at or below buffer blank in all dilutions. In 18 patients with type I von Willebrand's disease, a correlation coefficient of 0.899 was found comparing ELISA and EIA. All patients with variant von Willebrand's disease tested exhibited complete dose-response congruity of patient plasma and pooled standard plasma calibrated against the 1st International Standard for Plasma F VIII. Factor VIII concentrates also behaved like normal plasma in the assay.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

OpenAlex · 10.1080/00365518709168882

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 124

Metadata

Authors
Ingerslev, J.
Venue
Scandinavian Journal of Clinical and Laboratory Investigation
Publisher
Taylor & Francis
Published
1987-01-01
Volume
47
Issue
2
Pages
143-149
ISSN
0036-5513 (ISSN-L)
OpenAlex
W2152420062
Cited by
124
References
0
FWCI
3.31
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A sensitive ELISA for von Willebrand factor (vWf:Ag). https://app.cochat.ai/papers/10.1080/00365518709168882
The paper
Ingerslev, J. (1987). A sensitive ELISA for von Willebrand factor (vWf:Ag). Scandinavian Journal of Clinical and Laboratory Investigation. https://doi.org/10.1080/00365518709168882

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.