A sensitive ELISA for von Willebrand factor (vWf:Ag)
The DOI matches its OpenAlex record.
Abstract
A sensitive and precise enzyme-linked immunosorbent assay for the measurement of the von Willebrand factor (new nomenclature:vWf:Ag, previous name: F VIII:RAg) of plasma and factor VIII concentrates was constructed using a microtitre plate based sandwich technique. The coating antibody extracted vWf:Ag from standard and test material. Bound fraction was detected by a F(ab')2 peroxidase conjugate of the same antibody as used for coating. The sensitivity limit of the assay was 0.004 IU/ml, at least 10 times lower than the electro-immunoassay (EIA) using the same antibody, and better than any previously reported polyclonal ELISA for vWf:Ag. Imprecision between runs was 5.1% (CV%) at the 0.50 IU/ml level. Plasma from 30 healthy people gave 1.02 +/- 0.25 IU/ml (mean +/- 1SD) in the ELISA assay and 0.99 +/- 0.30 IU/ml (mean +/- 1SD) using electro-immunoassay (EIA) with a correlation coefficient of 0.967. Two cases of homozygous recessive von Willebrand's disease revealed vWf:Ag values at or below buffer blank in all dilutions. In 18 patients with type I von Willebrand's disease, a correlation coefficient of 0.899 was found comparing ELISA and EIA. All patients with variant von Willebrand's disease tested exhibited complete dose-response congruity of patient plasma and pooled standard plasma calibrated against the 1st International Standard for Plasma F VIII. Factor VIII concentrates also behaved like normal plasma in the assay.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Yudkin, J. S., Stehouwer, C. D. A., Emeis, J. J., & Coppack, S. W. (1999) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.19.4.972 · Cited by 2,465
Stehouwer, C. D. A., Gall, M.-A., Twisk, J. W. R., Knudsen, E., Emeis, J. J., & Parving, H.-H. (2002) · Diabetes · doi:10.2337/diabetes.51.4.1157 · Cited by 652
“The urinary albumin concentration was determined by radioimmunoassay (sensitivity, 0.5 mg/l; coefficient of variation [CV], 9% [16]) until 1992 and by enzyme-linked immunosorbent assay (ELISA) thereafter (sensitivity, 0.001 mg/l; CV, 8.3% [17]).”
MethodInfluentialImpact, Diagnosis and Treatment of von Willebrand Disease
Sadler, J. E., Berntorp, E., Bochkov, N., Boulyjenkov, V., Ginsburg, D., Meyer, D., Peake, I., Rodeghiero, F., Srivastava, A., & Mannucci, P. M. (2000) · Thrombosis and Haemostasis · doi:10.1055/s-0037-1613992 · Cited by 501
Jager, A., van Hinsbergh, V. W. M., Kostense, P. J., Emeis, J. J., Yudkin, J. S., Nijpels, G., Dekker, J. M., Heine, R. J., Bouter, L. M., & Stehouwer, C. D. A. (1999) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.19.12.3071 · Cited by 288
FEATURES OF ENDOTHELIAL DYSFUNCTION IN EARLY DIABETIC NEPHROPATHY
Jensen, T., Feldt-Rasmussen, B., Bjerre-Knudsen, J., & Deckert, T. (1989) · The Lancet · doi:10.1016/s0140-6736(89)91365-2 · Cited by 245
Andreotti, F., Pasceri, V., Hackett, D. R., Davies, G. J., Haider, A. W., & Maseri, A. (1996) · New England Journal of Medicine · doi:10.1056/nejm199601043340102 · Cited by 227
Changes of Plasma Coagulation and Fibrinolysis in Response to Mental Stress
Jern, C., Eriksson, E., Tengborn, L., Risberg, B., Wadenvik, H., & Jern, S. (1989) · Thrombosis and Haemostasis · doi:10.1055/s-0038-1646899 · Cited by 206
Deckert, T., Yokoyama, H., Mathiesen, E., Ronn, B., Jensen, T., Feldt-Rasmussen, B., Borch-Johnsen, K., & Jensen, J. S. (1996) · BMJ · doi:10.1136/bmj.312.7035.871 · Cited by 191
“Serum von Willebrand factor concentration was measured by enzyme linked immunosorbent assay (ELISA) (reagents from Dako A/S, Glostrup, Denmark; calibrator from WHO International Laboratory for Biological Standards, London).”
MethodRelationship between hemostatic abnormalities and neuroendocrine activity in heart failure
Sbarouni, E., Bradshaw, A., Andreotti, F., Tuddenham, E., Oakley, C. M., & Cleland, J. G. F. (1994) · American Heart Journal · doi:10.1016/0002-8703(94)90670-x · Cited by 169
The Pathology of Devil Facial Tumor Disease (DFTD) in Tasmanian Devils (Sarcophilus harrisii)
Loh, R., Bergfeld, J., Hayes, D., O'Hara, A., Pyecroft, S., Raidal, S., & Sharpe, R. (2006) · Veterinary Pathology · doi:10.1354/vp.43-6-890 · Cited by 158
Primary haemostasis in thyroid disease
MYRUP, B., BREGENGÅRD, C., & FABER, J. (1995) · Journal of Internal Medicine · doi:10.1111/j.1365-2796.1995.tb00899.x · Cited by 72
Effect of garlic powder on C-reactive protein and plasma lipids in overweight and smoking subjects
van Doorn, M. B., Santo, S. M. E., Meijer, P., Kamerling, I. M., Schoemaker, R. C., Dirsch, V., Vollmar, A., Haffner, T., Gebhardt, R., Cohen, A. F., et al. (2006) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/84.6.1324 · Cited by 68
Metadata
- Authors
- Ingerslev, J.
- Venue
- Scandinavian Journal of Clinical and Laboratory Investigation
- Publisher
- Taylor & Francis
- Published
- 1987-01-01
- Volume
- 47
- Issue
- 2
- Pages
- 143-149
- ISSN
- 0036-5513 (ISSN-L)
- OpenAlex
- W2152420062
- Cited by
- 124
- References
- 0
- FWCI
- 3.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.