Immunoturbidimetric determination of apolipoproteins A-1 and B in serum
The DOI matches its OpenAlex record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
Rapid immunochemical assays were developed for the determination of apolipoproteins A-1 and B in serum. The methods are based on the measurement of immunoprecipitation at a wavelength of 340 nm. Both assays are easy to perform, their reproducibilities are good (the coefficients of variation for within-run and between-run imprecisions are below 5%), and their correlations with radial immunodiffusion method are high (r = 0.96). The effect of storage on native serum specimens was also studied. Apolipoprotein B is stable at least 4 weeks in a refrigerator but in some specimens the level of apolipoprotein A-1 rises nearly 10% during this time. Repeated freezing and thawing, on the other hand, may have a harmful effect, especially on apolipoprotein B. Therefore, use of fresh serum specimens is recommended for both assays. The present method is well suited for routine measurements because it can be easily adapted to most clinical chemistry analysers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
PROTEIN MEASUREMENT WITH THE FOLIN PHENOL REAGENT
Lowry, O., Rosebrough, N., Farr, A. L., & Randall, R. (1951) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)52451-6 · Cited by 317,331
ARE APOLIPOPROTEINS BETTER DISCRIMINATORS THAN LIPIDS FOR ATHEROSCLEROSIS?
Avogaro, P., Bittolo Bon, G., Avogaro, P., Cazzolato, G., & Quinci, G. B. (1979) · The Lancet · doi:10.1016/s0140-6736(79)91375-8 · Cited by 523
A solvent system for delipidation of plasma or serum without protein precipitation
Cham, B. E., & Knowles, B. R. (1976) · Journal of Lipid Research · doi:10.1016/s0022-2275(20)37003-6 · Cited by 513
The Measurement of Apolipoprotein A-I and A-II Levels in Men and Women by Immunoassay
Cheung, M. C., & Albers, J. J. (1977) · Journal of Clinical Investigation · doi:10.1172/jci108767 · Cited by 381
Quantitation of apolipoprotein A-I of human plasma high density lipoprotein
Albers, J. J., Wahl, P. W., Cabana, V. G., Hazzard, W. R., & Hoover, J. J. (1976) · Metabolism · doi:10.1016/0026-0495(76)90060-3 · Cited by 342
Lipid-protein interactions in the plasma lipoproteins
Morrisett, J. D., Jackson, R. L., & Gotto, A. M. (1977) · Biochimica et Biophysica Acta (BBA) - Reviews on Biomembranes · doi:10.1016/0304-4157(77)90015-6 · Cited by 279
Schonfeld, G., & Pfleger, B. (1974) · Journal of Clinical Investigation · doi:10.1172/jci107758 · Cited by 218
Immunoturbidimetric assays of apolipoproteins A, AI, AII, and B in serum.
Rifai, N., & King, M. E. (1986) · Clinical Chemistry · doi:10.1093/clinchem/32.6.957 · Cited by 187
Discriminative value of lipids and apoproteins in coronary heart disease
De Backer, G., Rosseneu, M., & Deslypere, J. P. (1982) · Atherosclerosis · doi:10.1016/0021-9150(82)90150-2 · Cited by 170
Avogaro, P., Bon, G. B., Cazzolato, G., & Rorai, E. (1980) · Atherosclerosis · doi:10.1016/0021-9150(80)90094-5 · Cited by 130
Simultaneous measurement of plasma apolipoproteins A-I and B by electroimmunoassay.
Fruchart, J., Kora, I., Cachera, C., Barthelemy-Clavey, V., Duthilleul, P., & Moschetto, Y. (1982) · Clinical Chemistry · doi:10.1093/clinchem/28.1.59 · Cited by 87
Nephelometry of apolipoprotein B in human serum.
Heuck, C. C., & Schlierf, G. (1979) · Clinical Chemistry · doi:10.1093/clinchem/25.2.221 · Cited by 40
Quantitation of human serum apolipoprotein B by enzyme immunoassay
Holmquist, L. (1982) · Clinica Chimica Acta · doi:10.1016/0009-8981(82)90242-x · Cited by 30
Cited by
Jauhiainen, M., Koskinen, P., Ehnholm, C., Frick, M. H., Mänttäri, M., Manninen, V., & Huttunen, J. K. (1991) · Atherosclerosis · doi:10.1016/0021-9150(91)90007-p · Cited by 354
Human plasma phospholipid transfer protein causes high density lipoprotein conversion.
Jauhiainen, M., Metso, J., Pahlman, R., Blomqvist, S., van Tol, A., & Ehnholm, C. (1993) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)53575-4 · Cited by 342
Aro, A., Jauhiainen, M., Partanen, R., Salminen, I., & Mutanen, M. (1997) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/65.5.1419 · Cited by 281
Ruano, J., Lopez-Miranda, J., Fuentes, F., Moreno, J. A., Bellido, C., Perez-Martinez, P., Lozano, A., Gómez, P., Jiménez, Y., & Pérez Jiménez, F. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.06.078 · Cited by 234
“Apolipoprotein Al and apolipoprotein B levels were measured by immunoturbidimetry ( 19 ).”
MethodApolipoprotein E phenotypes in Finnish youths: a cross-sectional and 6-year follow-up study.
Lehtimäki, T., Moilanen, T., Viikari, J., Akerblom, H., Ehnholm, C., Rönnemaa, T., Marniemi, J., Dahlen, G., & Nikkari, T. (1990) · Journal of Lipid Research · doi:10.1016/s0022-2275(20)43170-0 · Cited by 207
Self-citation
Metadata
- Authors
- Riepponen, P., Marniemi, J., & Rautaoja, T.
- Venue
- Scandinavian Journal of Clinical and Laboratory Investigation
- Publisher
- Taylor & Francis
- Published
- 1987-01-01
- Volume
- 47
- Issue
- 7
- Pages
- 739-744
- ISSN
- 0036-5513 (ISSN-L)
- OpenAlex
- W2018944148
- Cited by
- 207
- References
- 13
- FWCI
- 3.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.