The Cobas Amplicor MTB Test for Detection of Mycobacterium tuberculosis Complex from Respiratory and Non-respiratory Clinical Specimens
The DOI matches its Crossref record.
Abstract
The Cobas Amplicor MTB test is a polymerase chain reaction (PCR) technique commonly used for direct detection of Mycobacterium tuberculosis in clinical samples. This assay is only validated for respiratory specimens, but many physicians also request PCR analyses for non-respiratory ones. 877 respiratory and 564 non-respiratory specimens were analysed by this test. Using culture results as standard, the sensitivity, specificity, positive (PPV) and negative predictive values (NPV) of the PCR were, respectively, 97.9%, 100%, 100% and 94.4% for smear-positive respiratory specimens, 68.8%, 99.2%, 87.5% and 97.5% for smear-negative respiratory samples, 57.8%, 98.6%, 78.8% and 96.4% for all non-respiratory specimens, and 42.4%, 98.6%, 66.7% and 96.4% for smear-negative non-respiratory specimens. 154 cerebrospinal fluid samples were analysed and the sensitivity, specificity, PPV and NPV were 55.6%, 97.2%, 55.6% and 97.2%, respectively. These results indicate that the Cobas Amplicor MTB test enables detection of tuberculosis in respiratory specimens, but does not perform well enough in non-respiratory specimens. The method fails particularly in cases where a reliable and rapid test is urgently needed, e.g. in tuberculous meningitis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Patel, V. B., Theron, G., Lenders, L., Matinyena, B., Connolly, C., Singh, R., Coovadia, Y., Ndung'u, T., & Dheda, K. (2013) · PLoS Medicine · doi:10.1371/journal.pmed.1001536 · Cited by 179
“Sensitivity was considerably better than in previous studies using commercially available or non-standardised PCR tools [9,32–34].”
ResultGreco, S., Girardi, E., Navarra, A., & Saltini, C. (2006) · Thorax · doi:10.1136/thx.2005.054908 · Cited by 162
Comparison of Two Molecular Methods for Rapid Diagnosis of Extrapulmonary Tuberculosis
Causse, M., Ruiz, P., Gutiérrez-Aroca, J. B., & Casal, M. (2011) · Journal of Clinical Microbiology · doi:10.1128/jcm.00491-11 · Cited by 145
“Specificity and negative predictive values were similar to those recorded for other molecular techniques used in nonrespiratory samples, while sensitivity and positive predictive values in our study were considerably better than the 57% and 78%, respectively, reported for the Cobas Amplicor MTB test in nonrespiratory…”
ResultMethods for Rapid Diagnosis of Meningitis Etiology in Adults
Poplin, V., Boulware, D. R., & Bahr, N. C. (2020) · Biomarkers in Medicine · doi:10.2217/bmm-2019-0333 · Cited by 119
Metadata
- Authors
- Jönsson, B., & Ridell, M.
- Venue
- Scandinavian Journal of Infectious Diseases
- Publisher
- Informa UK Limited
- Published
- 2003-01
- Volume
- 35
- Issue
- 6-7
- Pages
- 372-377
- ISSN
- 0036-5548 (ISSN-L)
- 1651-1980
- OpenAlex
- W2171503497
- Cited by
- 28
- References
- 0
- FWCI
- 1.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Cobas Amplicor MTB Test for Detection of Mycobacterium tuberculosis Complex from Respiratory and Non-respiratory Clinical Specimens. https://app.cochat.ai/papers/10.1080/00365540310012244
- The paper
- Jönsson, B., & Ridell, M. (2003). The Cobas Amplicor MTB Test for Detection of Mycobacterium tuberculosis Complex from Respiratory and Non-respiratory Clinical Specimens. Scandinavian Journal of Infectious Diseases. https://doi.org/10.1080/00365540310012244
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.