Multivariate SPC Charts for Monitoring Batch Processes
The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Abstract
The problem of using time-varying trajectory data measured on many process variables over the finite duration of a batch process is considered. Multiway principal-component analysis is used to compress the information contained in the data trajectories into low-dimensional spaces that describe the operation of past batches. This approach facilitates the analysis of operational and quality-control problems in past batches and allows for the development of multivariate statistical process control charts for on-line monitoring of the progress of new batches. Control limits for the proposed charts are developed using information from the historical reference distribution of past successful batches. The method is applied to data collected from an industrial batch polymerization reactor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Applied Multivariate Statistical Analysis.
Johnson, A. R., & Wichern, D. W. (1988) · Biometrics · doi:10.2307/2531616 · Cited by 11,353
Cross validatory choice and assessment of statistical predictions
Stone, M. (1974) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1974.tb00994.x · Cited by 10,881
Goodall, C. (1988) · Technometrics · doi:10.1080/00401706.1988.10488412 · Cited by 8,675
Jolliffe, I. T. (1986) · Springer Series in Statistics · doi:10.1007/978-1-4757-1904-8 · Cited by 8,273
Journal of The American Statistical Association
Fienberg, S. E. (2005) · Encyclopedia of Statistical Sciences · doi:10.1002/0471667196.ess1317 · Cited by 6,125
Spectral Analysis and its Applications.
Freiberger, W. F., Jenkins, G. M., & Watts, D. G. (1969) · Journal of the American Statistical Association · doi:10.2307/2286100 · Cited by 4,981
On the Kolmogorov-Smirnov Test for Normality with Mean and Variance Unknown
Lilliefors, H. W. (1967) · Journal of the American Statistical Association · doi:10.2307/2283970 · Cited by 4,530 · cited 1×
“Analysis of the batch data revealed that they were indeed well approximated by a Normal distribution (D’ Agostino and Stephens 1986; Lilliefors 1967) except at the first few time intervals.”
A User's Guide to Principal Components
Leigh, S., & Jackson, J. E. (1993) · Technometrics · doi:10.2307/1269292 · Cited by 3,332
Cross-Validatory Estimation of the Number of Components in Factor and Principal Components Models
Wold, S. (1978) · Technometrics · doi:10.1080/00401706.1978.10489693 · Cited by 2,601
A Use's Guide to Principal Components
Jackson, J. E. (1991) · Wiley Series in Probability and Statistics · doi:10.1002/0471725331 · Cited by 2,516
Estimating the error rate of a prediction rule: improvement on cross-validation
Efron, B. (1983) · Journal of the American Statistical Association · doi:10.1080/01621459.1983.10477973 · Cited by 2,300 · cited 1×
“When the purpose of a PCA analysis is to construct a model that will be used on future observations, then the suggested criterion to obtain the optimum number of components is cross-validation (Efron 1983, 1986; Stone 1974).”
(1962) · Journal of the Franklin Institute · doi:10.1016/0016-0032(62)91109-2 · Cited by 1,999
Koziol, J. A., D'Agostino, R. B., & Stephens, M. A. (1987) · Journal of Educational Statistics · doi:10.2307/1165059 · Cited by 1,982
King, T. (1987) · Technometrics · doi:10.1080/00401706.1987.10488292 · Cited by 1,859
Applied Multivariate Statistical Analysis
Dunn, C. (1989) · Technometrics · doi:10.1080/00401706.1989.10488530 · Cited by 1,608
Box, G. E. P. (1954) · The Annals of Mathematical Statistics · doi:10.1214/aoms/1177728786 · Cited by 1,513
Monitoring batch processes using multiway principal component analysis
Nomikos, P., & MacGregor, J. F. (1994) · AIChE Journal · doi:10.1002/aic.690400809 · Cited by 1,483
Self-citationControl Procedures for Residuals Associated With Principal Component Analysis
Jackson, J. E., & Mudholkar, G. S. (1979) · Technometrics · doi:10.1080/00401706.1979.10489779 · Cited by 1,237
The Exponentially Weighted Moving Average
Hunter, J. S. (1986) · Journal of Quality Technology · doi:10.1080/00224065.1986.11979014 · Cited by 1,136
Multivariate statistical monitoring of process operating performance
Kresta, J. V., Macgregor, J. F., & Marlin, T. E. (1991) · The Canadian Journal of Chemical Engineering · doi:10.1002/cjce.5450690105 · Cited by 989
Self-citationProcess monitoring and diagnosis by multiblock PLS methods
MacGregor, J. F., Jaeckle, C., Kiparissides, C., & Koutoudi, M. (1994) · AIChE Journal · doi:10.1002/aic.690400509 · Cited by 773
Self-citationMulti‐way principal components‐and PLS‐analysis
Wold, S., Geladi, P., Esbensen, K., & Öhman, J. (1987) · Journal of Chemometrics · doi:10.1002/cem.1180010107 · Cited by 748
Multivariate Control Charts for Individual Observations
Tracy, N. D., Young, J. C., & Mason, R. L. (1992) · Journal of Quality Technology · doi:10.1080/00224065.1992.12015232 · Cited by 597
How Biased is the Apparent Error Rate of a Prediction Rule?
Efron, B. (1986) · Journal of the American Statistical Association · doi:10.1080/01621459.1986.10478291 · Cited by 587
Statistical Intervals: A Guide for Practitioners
Hahn, G. J., & Meeker, W. Q. (1991) · Wiley Series in Probability and Statistics · doi:10.1002/9780470316771 · Cited by 566
(2016) · Journal of Quality Technology · doi:10.1080/00224065.2016.11918147 · Cited by 441
(1990) · Extending Explanation-Based Learning by Generalizing the Structure of Explanations · doi:10.1016/b978-0-273-08817-2.50013-3 · Cited by 438
AA, Evans, M., Hastings, N., & Peacock, B. (1994) · Journal of the American Statistical Association · doi:10.2307/2290968 · Cited by 426
Statistical Process Monitoring and Feedback Adjustment: A Discussion
Box, G., & Kramer, T. (1992) · Technometrics · doi:10.2307/1270028 · Cited by 331
[Statistical Process Monitoring and Feedback Adjustment]: Discussion
MacGregor, J. F. (1992) · Technometrics · doi:10.2307/1270030 · Cited by 318
Self-citationSelection of optimal regression models via cross‐validation
Osten, D. W. (1988) · Journal of Chemometrics · doi:10.1002/cem.1180020106 · Cited by 275
Cross-Validation in Principal Component Analysis
Krzanowski, W. J. (1987) · Biometrics · doi:10.2307/2531996 · Cited by 193
Principal component analysis of multivariate images
Geladi, P., Isaksson, H., Lindqvist, L., Wold, S., & Esbensen, K. (1989) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/0169-7439(89)80049-8 · Cited by 188
Some Problems Associated with the Analysis of Multiresponse Data
Box, G. E. P., Hunter, W. G., Macgregor, J. F., & Erjavec, J. (1973) · Technometrics · doi:10.1080/00401706.1973.10489009 · Cited by 184
Self-citationAnalysis of multi-way (multi-mode) data
Geladi, P. (1989) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/0169-7439(89)80108-x · Cited by 181
Real‐time qualitative analysis of the temporal shapes of (bio) process variables
Konstantinov, K. B., & Yoshida, T. (1992) · AIChE Journal · doi:10.1002/aic.690381104 · Cited by 101
An Extension of the MOSUM Technique for Quality Control
Bauer, P., & Hackl, P. (1980) · Technometrics · doi:10.2307/1268376 · Cited by 69
Cited by
PLS-regression: a basic tool of chemometrics
Wold, S., Sjöström, M., & Eriksson, L. (2001) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/s0169-7439(01)00155-1 · Cited by 10,084
Bro, R., & Smilde, A. K. (2014) · Anal. Methods · doi:10.1039/c3ay41907j · Cited by 3,038
De Maesschalck, R., Jouan-Rimbaud, D., & Massart, D. L. (2000) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/s0169-7439(99)00047-7 · Cited by 2,325
Data-driven Soft Sensors in the process industry
Kadlec, P., Gabrys, B., & Strandt, S. (2009) · Computers & Chemical Engineering · doi:10.1016/j.compchemeng.2008.12.012 · Cited by 1,845
Statistical process monitoring: basics and beyond
Joe Qin, S. (2003) · Journal of Chemometrics · doi:10.1002/cem.800 · Cited by 1,582
Metadata
- Authors
- Nomikos, P., & MacGregor, J. F.
- Venue
- Technometrics
- Publisher
- Informa UK Limited
- Published
- 1995-02
- Volume
- 37
- Issue
- 1
- Pages
- 41-59
- ISSN
- 0040-1706 (ISSN-L)
- 1537-2723
- OpenAlex
- W1978994389
- Cited by
- 1,422
- References
- 38
- FWCI
- 31.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.