Methods of fetal movement counting and the detection of fetal compromise
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Maternal perception of fetal movements is widely used as a marker of fetal viability and well-being. A reduction in fetal movements is associated with fetal hypoxia, increased incidence of stillbirth and fetal growth restriction (FGR). Therefore, a reduction in fetal movements has been proposed as a screening tool for FGR or fetal compromise. The problem of this approach is that there is no widely accepted definition of reduced fetal activity or 'alarm limits', and pregnant women are currently given a wide range of non-evidence-based advice. We have reviewed the background of published definitions and their potential usefulness in screening. A formal meta-analysis of these studies is not possible due to variation in methodology and definitions of reduced fetal movements. Assessment of fetal movements using formal fetal movement counting has shown equivocal results. Importantly, in all studies, there was a decrease in perinatal mortality suggesting a beneficial role for raising maternal awareness of fetal movements. Most studies implemented limits to define reduced fetal movements based on small groups of high risk pregnancies and obsolete counting methodology. A single case-control study developed 'normal limits' in a low risk population, and successfully implemented it prospectively for screening. At present, there is no evidence that any absolute definition of reduced fetal movements is of greater value than maternal subjective perception of reduced fetal movements in the detection of intrauterine fetal death or fetal compromise. Further investigation is required to determine an effective method of identifying patients with reduced fetal movements and to determine the best subsequent management.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maternal position during non‐stress test and fetal heart rate patterns
Cito, G., Luisi, S., Mezzesimi, A., Cavicchioli, C., Calonaci, G., & Petraglia, F. (2005) · Acta Obstetricia et Gynecologica Scandinavica · doi:10.1111/j.0001-6349.2005.00644.x · Cited by 56
Cited by
Tveit, J. V. H., Saastad, E., Stray-Pedersen, B., Børdahl, P. E., Flenady, V., Fretts, R., & Frøen, J. F. (2009) · BMC Pregnancy and Childbirth · doi:10.1186/1471-2393-9-32 · Cited by 196
“Despite the extreme nature of such limits, they are still widely used [43].”
Self-citationFetal growth restriction and stillbirth: Biomarkers for identifying at risk fetuses
King, V. J., Bennet, L., Stone, P. R., Clark, A., Gunn, A. J., & Dhillon, S. K. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2022.959750 · Cited by 52
“Further, a reduction in fetal movements is associated with fetal hypoxemia and FGR (Heazell and Frøen, 2008).”
BackgroundMeasurement of Maternal Mindful Awareness of Fetal Movement.
Kantrowitz‐Gordon, I., Cunningham, E., & Reynolds, N. (2019) · Journal of Midwifery & Women's Health · doi:10.1111/jmwh.12981 · Cited by 4
Metadata
- Authors
- Heazell, A. E. P., & Frøen, J. F.
- Venue
- Journal of Obstetrics and Gynaecology
- Publisher
- Informa UK Limited
- Published
- 2008-01
- Volume
- 28
- Issue
- 2
- Pages
- 147-154
- ISSN
- 0144-3615 (ISSN-L)
- 1364-6893
- OpenAlex
- W2150924640
- Cited by
- 174
- References
- 1
- FWCI
- 10.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Methods of fetal movement counting and the detection of fetal compromise. https://app.cochat.ai/papers/10.1080/01443610801912618
- The paper
- Heazell, A. E. P., & Frøen, J. F. (2008). Methods of fetal movement counting and the detection of fetal compromise. Journal of Obstetrics and Gynaecology. https://doi.org/10.1080/01443610801912618
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.