Improving Photovoltaic Module Efficiency Using Water Cooling
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
An effective way of improving efficiency and reducing the rate of thermal degradation of a photovoltaic (PV) module is by reducing the operating temperature of its surface. This can be achieved by cooling the module and reducing the heat stored inside the PV cells during operation. In this paper, long-term performance modeling of a proposed solar-water pumping system is carried out. The system, which is used for irrigation purposes, consists of a PV module cooled by water, a submersible water pump, and a water storage tank. Cooling of the PV panel is achieved by introducing water trickling configuration on the upper surface of the panel. An experimental rig is developed to investigate and evaluate PV module performance with the proposed cooling technique. The experimental results indicated that due to the heat loss by convection between water and the PV panel's upper surface, an increase of about 15% in system output is achieved at peak radiation conditions. Long-term performance of the system is estimated by integrating test results in a commercial transient simulation package using site radiation and ambient temperature data. The simulation results of the system's annual performance indicated that an increase of 5% in delivered energy from the PV module can be achieved during dry and warm seasons.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hybrid photovoltaic/thermal solar systems
Tripanagnostopoulos, Y., Nousia, T., Souliotis, M., & Yianoulis, P. (2002) · Solar Energy · doi:10.1016/s0038-092x(01)00096-2 · Cited by 602
Increased electrical yield via water flow over the front of photovoltaic panels
Krauter, S. (2004) · Solar Energy Materials and Solar Cells · doi:10.1016/j.solmat.2004.01.011 · Cited by 545
Performance of a concentrating photovoltaic/thermal solar collector
Coventry, J. S. (2005) · Solar Energy · doi:10.1016/j.solener.2004.03.014 · Cited by 428
Thermal regulation of photovoltaic cladding
Brinkworth, B. J., Cross, B. M., Marshall, R. H., & Yang, H. (1997) · Solar Energy · doi:10.1016/s0038-092x(97)00044-3 · Cited by 240
A validated model of naturally ventilated PV cladding
Brinkworth, B. J., Marshall, R. H., & Ibarahim, Z. (2000) · Solar Energy · doi:10.1016/s0038-092x(99)00076-6 · Cited by 140
Cited by
Yang, D., & Yin, H. (2011) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2011.2112363 · Cited by 221
“a large portion of solar energy is wasted through heat dissipation [13], [14].”
BackgroundEbaid, M. S. Y., Ghrair, A. M., & Al-Busoul, M. (2018) · Energy Conversion and Management · doi:10.1016/j.enconman.2017.10.074 · Cited by 188
Microchannel cooling of concentrator photovoltaics: A review
Gilmore, N., Timchenko, V., & Menictas, C. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2018.04.010 · Cited by 170
Madurai Elavarasan, R., Mudgal, V., Selvamanohar, L., Wang, K., Huang, G., Shafiullah, G. M., Markides, C. N., Reddy, K. S., & Nadarajah, M. (2022) · Energy Conversion and Management · doi:10.1016/j.enconman.2022.115278 · Cited by 164
Performance assessment of standalone PV systems for rural communities
Odeh, S., & Ibrik, I. (2022) · Australian Journal of Mechanical Engineering · doi:10.1080/14484846.2019.1679005 · Cited by 10
Self-citation
Metadata
- Authors
- Odeh, S., & Behnia, M.
- Venue
- Heat Transfer Engineering
- Publisher
- Informa UK Limited
- Published
- 2009-05
- Volume
- 30
- Issue
- 6
- Pages
- 499-505
- ISSN
- 0145-7632 (ISSN-L)
- 1521-0537
- OpenAlex
- W2021072420
- Cited by
- 334
- References
- 5
- FWCI
- 1.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.