Microchannel cooling of concentrator photovoltaics: A review
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The intensifying heat flux demands of concentrator photovoltaics requires innovation beyond conventional passive air cooling. Passive cooling is cost effective, reliable and does not consume power. Flat lens arrangements should allow large passive heat sinks to cool at solar concentrations of up to 2000 suns to 4000 suns (1 sun = 1000 W/m2). However, as solar concentrations increase so will the necessity of active cooling. The competitiveness of active cooling is enhanced by the capacity to harvest otherwise wasted thermal energy. Pairing with phase change materials presents an opportunity to stabilise the intermittent generation of solar thermal energy. Active microchannel cooling is a strong candidate for meeting the escalating heat flux demands of concentrator photovoltaics. For meeting short term-heat flux demands, established single phase microchannel cooling is most practical. Manifold microchannels yield superior performance to single layered microchannels, although they are more difficult to manufacture. For meeting long term heat flux demands, integration of boiling flows is promising. Jet impingement onto porous microstructures demonstrates effective mitigation of flow instabilities. Future studies should apply microchannel cooling directly to concentrator photovoltaics, particularly two-phase systems. They should also test microchannel cooling over larger heater areas and consider manufacturability of heat sinks. Novel directions should also be explored, such as alteration of typically rectangular and straight manifold microchannels or use of micro-valves to suppress boiling instabilities. Incipient cooling methods, including vortex shedding, ionic jet impingement, slug flow and shear driven gas flow, may also warrant further investigations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The contribution of outdoor air pollution sources to premature mortality on a global scale
Lelieveld, J., Evans, J. S., Fnais, M., Giannadaki, D., & Pozzer, A. (2015) · Nature · doi:10.1038/nature15371 · Cited by 5,977
Review on thermal energy storage with phase change materials and applications
Sharma, A., Tyagi, V. V., Chen, C. R., & Buddhi, D. (2009) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2007.10.005 · Cited by 5,936
Cui, T., Xuan, Y., & Li, Q. (2016) · Energy Conversion and Management · doi:10.1016/j.enconman.2016.01.008 · Cited by 245
Metadata
- Authors
- Gilmore, N., Timchenko, V., & Menictas, C.
- Venue
- Renewable and Sustainable Energy Reviews
- Publisher
- Elsevier BV
- Published
- 2018-07
- Volume
- 90
- Pages
- 1041-1059
- ISSN
- 1364-0321 (ISSN-L)
- OpenAlex
- W2800956249
- Cited by
- 170
- References
- 3
- FWCI
- 9.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Microchannel cooling of concentrator photovoltaics: A review. https://app.cochat.ai/papers/10.1016/j.rser.2018.04.010
- The paper
- Gilmore, N., Timchenko, V., & Menictas, C. (2018). Microchannel cooling of concentrator photovoltaics: A review. Renewable and Sustainable Energy Reviews. https://doi.org/10.1016/j.rser.2018.04.010
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.