The DOI matches its Crossref record.
Use of Trialkyl Ammonium Phosphate (TAAP) Buffers in Reverse Phase HPLC for High Resolution and High Recovery of Peptides and Proteins
Abstract
A new buffer system compatible with reverse phase high pressure liquid chromatography (RP -HPLC) column packings and giving high recoveries and high resolution for peptides and proteins is described. The TEAP buffer (triethylammonium phosphate), one of several TAAP buffers (trialkylammonium phosphate) compatible with RP-HPLC, gives high resolution and high recovery for closely related peptides or proteins as well as day to day reproducibility. It is UV transparent to less than 200 nm, extremely versatile, and could probably be used for several other classes of compounds (phosphatidyl cholines and sphingomyelin, for example). Furthermore, this system is compatible with in vitro and in vivo biological systems after removal of the organic solvent. We have applied our system to the purification of radioactive peptides, i.e. the separation and total recovery of tritiated luteinizing hormone releasing factor (LRF) from closely related radioactive impurities. Peptides and proteins as different as LRF, somatostatin, insulin and cytochrome C are easily separated and recovered. Application to peptide mapping is also described. The influence of flow rate, temperature and column packings on resolution is discussed and illustrated. Linearity between load and integrated response is demonstrated over four order of magnitude while retention time for a particular component remains constant. A flow rate of 1–1.5 ml/min and ambient or lower temperatures gives optimal resolution. Furthermore, it was found that the higher the hydrophobicities of the support was, the higher the resolution, but also possible the higher the chances for peptide or protein loss.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Production of a novel neuropeptide encoded by the calcitonin gene via tissue-specific RNA processing
Rosenfeld, M. G., Mermod, J.-J., Amara, S. G., Swanson, L. W., Sawchenko, P. E., Rivier, J., Vale, W. W., & Evans, R. M. (1983) · Nature · doi:10.1038/304129a0 · Cited by 2,302
Self-citationPurification and sequence of a presynaptic peptide toxin from Conus geographus venom
Olivera, B. M., McIntosh, J. M., Curz, L. J., Luque, F. A., & Gray, W. R. (1984) · Biochemistry · doi:10.1021/bi00317a001 · Cited by 419
Key role of CRF in the skin stress response system
Slominski, A. T., Zmijewski, M. A., Zbytek, B., Tobin, D. J., Theoharides, T. C., & Rivier, J. (2013) · Endocrine Reviews · doi:10.1210/er.2012-1092 · Cited by 400
Self-citationYeast metallothionein. Sequence and metal-binding properties.
Winge, D. R., Nielson, K. B., Gray, W. R., & Hamer, D. H. (1985) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(17)38592-7 · Cited by 266
Bennett, H. P. J., Browne, C. A., & Solomon, S. (1981) · Biochemistry · doi:10.1021/bi00519a004 · Cited by 253
Metadata
- Authors
- Rivier, J. E.
- Venue
- Journal of Liquid Chromatography
- Publisher
- Informa UK Limited
- Published
- 1978-01
- Volume
- 1
- Issue
- 3
- Pages
- 343-366
- ISSN
- 0148-3919 (ISSN-L)
- OpenAlex
- W2040989387
- Cited by
- 345
- References
- 0
- FWCI
- 31.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Use of Trialkyl Ammonium Phosphate (TAAP) Buffers in Reverse Phase HPLC for High Resolution and High Recovery of Peptides and Proteins. https://app.cochat.ai/papers/10.1080/01483917808060004
- The paper
- Rivier, J. E. (1978). Use of Trialkyl Ammonium Phosphate (TAAP) Buffers in Reverse Phase HPLC for High Resolution and High Recovery of Peptides and Proteins. Journal of Liquid Chromatography. https://doi.org/10.1080/01483917808060004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.