Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 345

The DOI matches its Crossref record.

Use of Trialkyl Ammonium Phosphate (TAAP) Buffers in Reverse Phase HPLC for High Resolution and High Recovery of Peptides and Proteins

Rivier, Jean E.·1978·Journal of Liquid Chromatography

Abstract

A new buffer system compatible with reverse phase high pressure liquid chromatography (RP -HPLC) column packings and giving high recoveries and high resolution for peptides and proteins is described. The TEAP buffer (triethylammonium phosphate), one of several TAAP buffers (trialkylammonium phosphate) compatible with RP-HPLC, gives high resolution and high recovery for closely related peptides or proteins as well as day to day reproducibility. It is UV transparent to less than 200 nm, extremely versatile, and could probably be used for several other classes of compounds (phosphatidyl cholines and sphingomyelin, for example). Furthermore, this system is compatible with in vitro and in vivo biological systems after removal of the organic solvent. We have applied our system to the purification of radioactive peptides, i.e. the separation and total recovery of tritiated luteinizing hormone releasing factor (LRF) from closely related radioactive impurities. Peptides and proteins as different as LRF, somatostatin, insulin and cytochrome C are easily separated and recovered. Application to peptide mapping is also described. The influence of flow rate, temperature and column packings on resolution is discussed and illustrated. Linearity between load and integrated response is demonstrated over four order of magnitude while retention time for a particular component remains constant. A flow rate of 1–1.5 ml/min and ambient or lower temperatures gives optimal resolution. Furthermore, it was found that the higher the hydrophobicities of the support was, the higher the resolution, but also possible the higher the chances for peptide or protein loss.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/01483917808060004

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 345

Metadata

Authors
Rivier, J. E.
Venue
Journal of Liquid Chromatography
Published
1978-01
Volume
1
Issue
3
Pages
343-366
ISSN
0148-3919 (ISSN-L)
OpenAlex
W2040989387
Cited by
345
References
0
FWCI
31.64
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Use of Trialkyl Ammonium Phosphate (TAAP) Buffers in Reverse Phase HPLC for High Resolution and High Recovery of Peptides and Proteins. https://app.cochat.ai/papers/10.1080/01483917808060004
The paper
Rivier, J. E. (1978). Use of Trialkyl Ammonium Phosphate (TAAP) Buffers in Reverse Phase HPLC for High Resolution and High Recovery of Peptides and Proteins. Journal of Liquid Chromatography. https://doi.org/10.1080/01483917808060004

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.