The DOI matches its Crossref record.
The Use of Perfluorinated Carboxylic Acids in the Reversed-Phase HPLC of Peptides
Abstract
The relative effectiveness of trifluoroacetic acid (TFA), pentafluoropropanoic acid (PFPA), heptafluorobutyric acid (HFBA) and undecafluorocaproic acid (UFCA) as hydrophobic counter-ions in the reversedphase high performance liquid chromatography (RP-HPLC) of peptides was assessed. Four solvent systems were compared each containing 0.01M of a perfluorocarboxylic acid throughout. Twelve standard peptides and proteins were loaded onto the RP-HPLC column which was eluted with a linear gradient of 20-58.4% aqueous acetonitrile over 90 minutes. The retention times of the peptide standards were different in each solvent system. In progressing from TFA to PFPA, HFBA and UFCA all the peptides showed greater retention times. However, the effect was most marked with peptides having the greatest number of basic groups. By exploiting this behaviour a different type of chromatography can be introduced into the RP-HPLC purification of peptides. For instance, column fractions obtained from the use of the TFA solvent system can be re-chromatographed in a solvent system containing HFBA. It is possible by this procedure to purify naturally occurring peptides on the basis of their overall positive charges. At 0.01M each acid solution is sufficiently U.V. transparent to permit monitoring of column effluents at 210 nm. TFA, PFPA, HFBA and UFCA solvent systems are also completely volatile and this property facilitates the bioassay, radioimmunoassay and amino acid analysis of column fractions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Close similarity of epidermal growth factor receptor and v-erb-B oncogene protein sequences
Downward, J., Yarden, Y., Mayes, E., Scrace, G., Totty, N., Stockwell, P., Ullrich, A., Schlessinger, J., & Waterfield, M. D. (1984) · Nature · doi:10.1038/307521a0 · Cited by 2,516
Waterfield, M. D., Scrace, G. T., Whittle, N., Stroobant, P., Johnsson, A., Wasteson, Å., Westermark, B., Heldin, C.-H., Huang, J. S., & Deuel, T. F. (1983) · Nature · doi:10.1038/304035a0 · Cited by 1,616
Key role of CRF in the skin stress response system
Slominski, A. T., Zmijewski, M. A., Zbytek, B., Tobin, D. J., Theoharides, T. C., & Rivier, J. (2013) · Endocrine Reviews · doi:10.1210/er.2012-1092 · Cited by 400
Bennett, H. P. J., Browne, C. A., & Solomon, S. (1981) · Biochemistry · doi:10.1021/bi00519a004 · Cited by 253
Self-citation
Metadata
- Authors
- Bennett, H. P. J., Browne, C. A., & Solomon, S.
- Venue
- Journal of Liquid Chromatography
- Publisher
- Informa UK Limited
- Published
- 1980-01
- Volume
- 3
- Issue
- 9
- Pages
- 1353-1365
- ISSN
- 0148-3919 (ISSN-L)
- OpenAlex
- W2084834562
- Cited by
- 208
- References
- 0
- FWCI
- 15.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Use of Perfluorinated Carboxylic Acids in the Reversed-Phase HPLC of Peptides. https://app.cochat.ai/papers/10.1080/01483918008062781
- The paper
- Bennett, H. P. J., Browne, C. A., & Solomon, S. (1980). The Use of Perfluorinated Carboxylic Acids in the Reversed-Phase HPLC of Peptides. Journal of Liquid Chromatography. https://doi.org/10.1080/01483918008062781
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.