A Signal Extraction Approach to Modeling Hormone Time Series with Pulses and a Changing Baseline
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Hormones serve as regulating signals for many biological processes. In recent years, it was determined that many hormones are secreted in a pulsatile manner and that the pulsatile secretion pattern, in addition to the absolute concentration level, is important in regulating biological processes. Consequently, it is necessary to characterize the latent secretion patterns from measurements of concentration levels. The characterization is complicated by the presence of a biological circadian rhythm. When hormone concentrations are plotted over time, the resultant time series usually exhibits occasional short rises superimposed on a slowly changing baseline. This is a result of a mixture of pulsatile secretions and a circadian rhythm. In this article we present a signal extraction approach to model simultaneously a slowly changing component and a pulsatile component of a time series. A smoothing spline is used to model the baseline, and a multiprocess dynamic linear model is used to model the pulsatile component. An additive structure is assumed, and both components are estimated simultaneously using a multiprocess Kalman filter. The unknown parameters are estimated by approximate maximum likelihood. The locations and amplitudes of the pulses are also estimated as posterior means via the multiprocess Kalman filter. Bayesian confidence intervals can be constructed for the baseline. This approach is found to be robust in simulated data and effective in modeling hormone time series.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Clarke, I. J., Cummins, J. T., Findlay, J. K., Burman, K. J., & Doughton, B. W. (2008) · Neuroendocrinology · doi:10.1159/000123982 · Cited by 122
Cited by
Dysregulation of the hypothalamic‐pituitary‐adrenal (HPA) axis in irritable bowel syndrome
Chang, L., Sundaresh, S., Elliott, J., Anton, P. A., Baldi, P., Licudine, A., Mayer, M., Vuong, T., Hirano, M., Naliboff, B. D., et al. (2009) · Neurogastroenterology & Motility · doi:10.1111/j.1365-2982.2008.01171.x · Cited by 253
Motivations and Methods for Analyzing Pulsatile Hormone Secretion
Veldhuis, J. D., Keenan, D. M., & Pincus, S. M. (2008) · Endocrine Reviews · doi:10.1210/er.2008-0005 · Cited by 223
Adinoff, B., Krebaum, S. R., Chandler, P. A., Ye, W., Brown, M. B., & Williams, M. J. (2005) · Alcoholism: Clinical & Experimental Research · doi:10.1097/01.alc.0000158940.05529.0a · Cited by 74
“The SBPP modeling technique (Guo et al., 1999) may have uncovered group differences in cortisol amplitude not reported by others.”
MethodSelf-citationAdrenocortical and pituitary glucocorticoid feedback in abstinent alcohol-dependent women
Adinoff, B., Best, S. E., Ye, W., Williams, M. J., & Iranmenesh, A. (2010) · Alcoholism: Clinical and Experimental Research · doi:10.1111/j.1530-0277.2010.01164.x · Cited by 20
“Therefore, pulsatile characteristics were assessed by the Smoothing Baseline Pulse Pulses (SBPP) algorithm (Guo et al., 1999), which allows for a changing baseline.”
Method
Metadata
- Authors
- Guo, W., Wang, Y., & Brown, M. B.
- Venue
- Journal of the American Statistical Association
- Publisher
- Informa UK Limited
- Published
- 1999-09
- Volume
- 94
- Issue
- 447
- Pages
- 746-756
- ISSN
- 0162-1459 (ISSN-L)
- 1537-274X
- OpenAlex
- W2008633988
- Cited by
- 45
- References
- 1
- FWCI
- 2.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Signal Extraction Approach to Modeling Hormone Time Series with Pulses and a Changing Baseline. https://app.cochat.ai/papers/10.1080/01621459.1999.10474177
- The paper
- Guo, W., Wang, Y., & Brown, M. B. (1999). A Signal Extraction Approach to Modeling Hormone Time Series with Pulses and a Changing Baseline. Journal of the American Statistical Association. https://doi.org/10.1080/01621459.1999.10474177
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.