Rapid Measurement of Chlorophylls with a Microplate Reader
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
This paper describes a robust and rapid procedure for measuring chlorophyll using a microplate reader. The procedure enables direct translation of any published equation developed on a 1-cm pathlength spectrophotometer to any format microplate with any sample volume. Chlorophylls were extracted with methanol because it is compatible with cheap polystyrene plates; however, the principles apply to any solvent system. Keys to obtaining accurate and precise results include determining pathlength in the same solvent used to extract chlorophylls, and avoiding evaporation. After taking these precautions, there was a strong linear 1:1 relationship (R2 = 0.98–0.99) between microplate and spectrophotometer estimates of chlorophyll concentrations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
COPPER ENZYMES IN ISOLATED CHLOROPLASTS. POLYPHENOLOXIDASE IN BETA VULGARIS
Arnon, D. I. (1949) · Plant Physiology · doi:10.1104/pp.24.1.1 · Cited by 22,451 · cited 3×
“The most tried and true methods for measuring chlorophylls involves extraction with an organic solvent and subsequent measurement on a spectrophotometer (Arnon, 1949; Porra, 2002; Ritchie, 2006).”
MethodPorra, R. J. (2002) · Photosynthesis Research · doi:10.1023/a:1020470224740 · Cited by 1,371 · cited 3×
“The most tried and true methods for measuring chlorophylls involves extraction with an organic solvent and subsequent measurement on a spectrophotometer (Arnon, 1949; Porra, 2002; Ritchie, 2006).”
BackgroundMethodRitchie, R. J. (2006) · Photosynthesis Research · doi:10.1007/s11120-006-9065-9 · Cited by 1,320 · cited 6×
“…estimating chlorophylls are more complicated due to the presence of two absorbing molecules (chlorophyll a and chlorophyll b), but such detail is unimportant for our purposes here (for a full discussion and derivation of equations for chlorophylls see Martinez and Damidaux, 1993; Ritchie, 2006).”
BackgroundMethodInfluential日本植物生理学会 (1959) · Medical Entomology and Zoology · Cited by 950
Chapman, S. C., & Barreto, H. J. (1997) · Agronomy Journal · doi:10.2134/agronj1997.00021962008900040004x · Cited by 478 · cited 1×
“Chlorophyll content is also used as an indirect indicator of nitrogen (N) content (Chapman and Barreto, 1997; Wang et al., 2004) owing to the significant proportion of leaf N in pigmentprotein complexes.”
BackgroundChang, S. X., & Robison, D. J. (2003) · Forest Ecology and Management · doi:10.1016/s0378-1127(03)00004-5 · Cited by 189 · cited 2×
“This requirement for calibration is problematic because calibrations often vary among genotypes or with growth conditions (Chang and Robison, 2003; Wang et al., 2004), and thus multiple calibrations must be established for studies comparing genotypes or growing the same genotype under different conditions.”
BackgroundMadeira, A. C., Ferreira, A. C., de Varennes, A., & Vieira, M. I. (2003) · Communications in Soil Science and Plant Analysis · doi:10.1081/css-120024779 · Cited by 145 · cited 2×
“Portable chlorophyll meters (e.g., SPAD) permit rapid relative measures of chlorophyll content and thus meet one criterion for high-throughput methods (Chang and Robison, 2003; Madeira et al., 2003; Bonneville and Fyles, 2006).”
BackgroundWang, Q., Chen, J., & Li, Y. C. (2004) · Journal of Plant Nutrition · doi:10.1081/pln-120028878 · Cited by 110 · cited 3×
“This requirement for calibration is problematic because calibrations often vary among genotypes or with growth conditions (Chang and Robison, 2003; Wang et al., 2004), and thus multiple calibrations must be established for studies comparing genotypes or growing the same genotype under different conditions.”
BackgroundFischer, B. B., Wiesendanger, M., & Eggen, R. I. L. (2006) · Plant and Cell Physiology · doi:10.1093/pcp/pcj085 · Cited by 91 · cited 1×
“E-mail: charles.warren@bio.usyd.edu.au 1321 Fischer et al., 2006; Ritchie, 2006) and chlorophyll content is used to drive models of radiation interception and net primary production (Sari et al., 2005).”
MethodBonneville, M., & Fyles, J. W. (2006) · Communications in Soil Science and Plant Analysis · doi:10.1080/00103620500449385 · Cited by 32 · cited 1×
“, SPAD) permit rapid relative measures of chlorophyll content and thus meet one criterion for high-throughput methods (Chang and Robison, 2003; Madeira et al., 2003; Bonneville and Fyles, 2006).”
Background
Cited by
Contrasting cadmium resistance strategies in two metallicolous populations of Arabidopsis halleri
Corso, M., Schvartzman, M. S., Guzzo, F., Souard, F., Malkowski, E., Hanikenne, M., & Verbruggen, N. (2018) · New Phytologist · doi:10.1111/nph.14948 · Cited by 110
The variegated canalized-1 tomato mutant is linked to photosystem assembly
Wijesingha Ahchige, M., Fisher, J., Sokolowska, E., Lyall, R., Illing, N., Skirycz, A., Zamir, D., Alseekh, S., & Fernie, A. R. (2024) · Computational and Structural Biotechnology Journal · doi:10.1016/j.csbj.2024.10.028 · Cited by 2
Metadata
- Authors
- Warren, C. R.
- Venue
- Journal of Plant Nutrition
- Publisher
- Informa UK Limited
- Published
- 2008-06-18
- Volume
- 31
- Issue
- 7
- Pages
- 1321-1332
- ISSN
- 0190-4167 (ISSN-L)
- 1532-4087
- OpenAlex
- W1970403842
- Cited by
- 206
- References
- 10
- FWCI
- 1.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Rapid Measurement of Chlorophylls with a Microplate Reader. https://app.cochat.ai/papers/10.1080/01904160802135092
- The paper
- Warren, C. R. (2008). Rapid Measurement of Chlorophylls with a Microplate Reader. Journal of Plant Nutrition. https://doi.org/10.1080/01904160802135092
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.