Do regression-based computer algorithms for determining the ventilatory threshold agree?
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The determination of the ventilatory threshold has been a persistent problem in research and clinical practice. Several computerized methods have been developed to overcome the subjectivity of visual methods but it remains unclear whether different computerized methods yield similar results. The purpose of this study was to compare nine regression-based computerized methods for the determination of the ventilatory threshold. Two samples of young and healthy volunteers (n = 30 each) participated in incremental treadmill protocols to volitional fatigue. The ventilatory data were averaged in 20-s segments and analysed with a computer program. Significant variance among methods was found in both samples (Sample 1: F = 11.50; Sample 2: F = 11.70, P < 0.001 for both). The estimates of the ventilatory threshold ranged from 2.47 litres.min(-1) (71% VO2max) to 3.13 litres.min(-1) (90% VO2max) in Sample 1 and from 2.37 litres.min(-1) (67% VO2max) to 3.03 litres.min(-1) (83% VO2max) in Sample 2. The substantial differences between methods challenge the practice of relying on any single computerized method. A standardized protocol, likely based on a combination of methods, might be necessary to increase the methodological consistency in both research and clinical practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
A new method for detecting anaerobic threshold by gas exchange
Beaver, W. L., Wasserman, K., & Whipp, B. J. (1986) · Journal of Applied Physiology · doi:10.1152/jappl.1986.60.6.2020 · Cited by 4,103
Validity and reliability of combining three methods to determine ventilatory threshold
GASKILL, S. E., RUBY, B. C., WALKER, A. J., SANCHEZ, O. A., SERFASS, R. C., & LEON, A. S. (2001) · Medicine and Science in Sports and Exercise · doi:10.1097/00005768-200111000-00007 · Cited by 444
Reproducibility of aerobic and anaerobic thresholds in 20–50 year old men
Aunola, S., & Rusko, H. (1984) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00776600 · Cited by 141 · cited 2×
“Numerous comparative studies have established that, although the reliability of such methods is generally acceptable (Aunola & Rusko, 1984; Gladden et al ., 1985; Hebestreit, Staschen, & Hebestreit, 2000; Meyer et al ., 1996), there are other problems.”
Background
Cited by
Ekkekakis, P., Parfitt, G., & Petruzzello, S. J. (2011) · Sports Medicine · doi:10.2165/11590680-000000000-00000 · Cited by 1,215
Self-citationDecker, E. S., & Ekkekakis, P. (2017) · Psychology of Sport and Exercise · doi:10.1016/j.psychsport.2016.09.005 · Cited by 139
Kim, K. J., Rivas, E., Prejean, B., Frisco, D., Young, M., & Downs, M. (2021) · Frontiers in Physiology · doi:10.3389/fphys.2021.782167 · Cited by 17
“However, two regression lines skim the slope of data points from left to right and stop as soon as its criterion is satisfied; thus, the algorithm for searching VT 1 might estimate lower VO 2 compared with the other methods depending on the amount of noise in the data (Ekkekakis et al., 2008).”
MethodInfluential
Metadata
- Authors
- Ekkekakis, P., Lind, E., Hall, E. E., & Petruzzello, S. J.
- Venue
- Journal of Sports Sciences
- Publisher
- Informa UK Limited
- Published
- 2008-07
- Volume
- 26
- Issue
- 9
- Pages
- 967-976
- ISSN
- 0264-0414 (ISSN-L)
- 1466-447X
- OpenAlex
- W2127871157
- Cited by
- 44
- References
- 4
- FWCI
- 5.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Do regression-based computer algorithms for determining the ventilatory threshold agree? https://app.cochat.ai/papers/10.1080/02640410801910269
- The paper
- Ekkekakis, P., Lind, E., Hall, E. E., & Petruzzello, S. J. (2008). Do regression-based computer algorithms for determining the ventilatory threshold agree? Journal of Sports Sciences. https://doi.org/10.1080/02640410801910269
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.