Validity of vertical jump measurement devices
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
Vertical jump height is thought to provide a valuable index of muscular power, which is an important factor in sports performance and for assessing the mobility and functional capacity of injured or aged individuals. The purpose of the present study was to investigate the criterion validity of four popular devices for measuring vertical jump height. A belt mat, contact mat, portable force plate, and Vertec were compared to a criterion device, a laboratory force plate. Forty participants performed three maximal countermovement jumps on each device in a counterbalanced order, using block randomization. The criterion device presented the highest mean value (50.3 cm). The portable force plate and belt mat devices recorded similar jump height values to the criterion device (within 1 cm). The contact mat and Vertec devices recorded significantly lower values than the criterion device (P < 0.001). The mean difference ± limits of agreement were: belt mat -0.1 ± 5.5 cm, contact mat -11.7 ± 6.4 cm, portable force plate -0.8 ± 3.9 cm, and Vertec -2.4 ± 6.6 cm. In conclusion, the portable force plate and belt mat devices provided valid measures of vertical jump height, whereas the Vertec and contact mat devices did not.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Atkinson, G., & Nevill, A. M. (1998) · Sports Medicine · doi:10.2165/00007256-199826040-00002 · Cited by 3,779 · cited 2×
“Validity is generally referred to as the ability of a measurement tool to reflect what it is designed to measure (Atkinson & Nevill, 1998).”
BackgroundJournal of Strength and Conditioning Research: Among the Best News You Can Use
Koziris, L. P. (2003) · Strength and Conditioning Journal · doi:10.1519/00126548-200302000-00014 · Cited by 1,579
The Journal of Strength and Conditioning Research
Hanna, W. (2013) · Wilderness & Environmental Medicine · doi:10.1016/j.wem.2013.06.015 · Cited by 1,569
Research Methods in Physical Activity
Thomas, J. R., & Nelson, J. K. (1990) · Cited by 1,562
Research methods in physical activity
Maughan, R. (2017) · Journal of Sports Sciences · doi:10.1080/02640414.2016.1169035 · Cited by 1,250
Reliability and Factorial Validity of Squat and Countermovement Jump Tests
Markovic, G., Dizdar, D., Jukic, I., & Cardinale, M. (2004) · Journal of Strength and Conditioning Research · doi:10.1519/00124278-200408000-00028 · Cited by 1,097
Moir, G. L. (2008) · Measurement in Physical Education and Exercise Science · doi:10.1080/10913670802349766 · Cited by 352 · cited 3×
“The discrepancies (Moir, 2008: –9.4 cm; Aragón-Vargas, 2000: –11.8 cm) are thought to be due to the fact that the flight time algorithms underpinning any contact mat device fail to account for displacement of the centre of mass prior to take-off.”
BackgroundMethodInfluentialNevill, A. M., & Atkinson, G. (1997) · British Journal of Sports Medicine · doi:10.1136/bjsm.31.4.314 · Cited by 317 · cited 2×
“In the presence of heteroscedasticity, the log-transformed values were computed and the ratio limits were reported (Nevill & Atkinson, 1997).”
MethodPotentiation of the mechanical behavior of the human skeletal muscle through prestretching
BOSCO, C., & KOMI, P. V. (1979) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1979.tb06427.x · Cited by 287 · cited 1×
“…action of the lower limbs during a vertical jump is thought to provide a valuable index of the muscular power of the legs in sedentary individuals, elite athletes, and some patient groups (Bach, Jones, Sweet, & Hager, 1994; Bosco & Komi, 1979, 1980; Markovic, Dizdar, Jukic, & Cardinale, 2004).”
BackgroundEvaluation of Four Vertical Jump Tests: Methodology, Reliability, Validity, and Accuracy
Aragón, L. F. (2000) · Measurement in Physical Education and Exercise Science · doi:10.1207/s15327841mpee0404_2 · Cited by 272
VALIDITY OF TWO ALTERNATIVE SYSTEMS FOR MEASURING VERTICAL JUMP HEIGHT
LEARD, J. S., CIRILLO, M. A., KATSNELSON, E., KIMIATEK, D. A., MILLER, T. W., TREBINCEVIC, K., & GARBALOSA, J. C. (2007) · Journal of Strength and Conditioning Research · doi:10.1519/00124278-200711000-00055 · Cited by 267
Influence of aging on the mechanical behavior of leg extensor muscles
Bosco, C., & Komi, P. V. (1980) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00421329 · Cited by 265 · cited 1×
“…action of the lower limbs during a vertical jump is thought to provide a valuable index of the muscular power of the legs in sedentary individuals, elite athletes, and some patient groups (Bach, Jones, Sweet, & Hager, 1994; Bosco & Komi, 1979, 1980; Markovic, Dizdar, Jukic, & Cardinale, 2004).”
BackgroundCORMIE, P., McGUIGAN, M. R., & NEWTON, R. U. (2010) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181d392e8 · Cited by 254 · cited 1×
“Cormie, McGuigan, & Newton, 2010 ) rather than providing just a single measure of jump height, which allows for more detailed analysis of an individual's training or rehabilitation requirements.”
BackgroundBach, B. R., Jones, G. T., Sweet, F. A., & Hager, C. A. (1994) · The American Journal of Sports Medicine · doi:10.1177/036354659402200606 · Cited by 199
Test-Retest Reliability of Three Different Countermovement Jumping Tests
Slinde, F., Suber, C., Suber, L., Edwén, C. E., & Svantesson, U. (2008) · Journal of Strength and Conditioning Research · doi:10.1519/jsc.0b013e3181660475 · Cited by 190
Kibele, A. (1998) · Journal of Applied Biomechanics · doi:10.1123/jab.14.1.105 · Cited by 177 · cited 3×
“Previous research has identified that the descending phase is longer than the ascending phase, as participants land in a slightly crouched manner (Aragón-Vargas, 2000; Kibele, 1998).”
BackgroundInfluentialValidity and Reliability of Methods for Testing Vertical Jumping Performance
Hatze, H. (1998) · Journal of Applied Biomechanics · doi:10.1123/jab.14.2.127 · Cited by 168 · cited 1×
“…force with a laboratory force plate during take-off using an appropriate sampling frequency and double integration of the recorded signal is considered the ‘‘gold standard’’ reference method for the measurement of vertical jump height (Hatze, 1998; Vanrenterghem, De Clercq, & Van Cleven, 2001).”
MethodVanrenterghem, J., Clercq, D. D., & Cleven, P. V. (2001) · Ergonomics · doi:10.1080/00140130118100 · Cited by 99
Validity and reliability of the Newtest Powertimer 300-series® testing system
Enoksen, E., Tønnessen, E., & Shalfawi, S. A. I. (2009) · Journal of Sports Sciences · doi:10.1080/02640410802448723 · Cited by 85 · cited 1×
“8 cm (Enoksen, Tonnessen, & Shalfawi, 2009 ), which is very similar to the 3 cm value noted above, and appears to explain the discrepancy between our corrected contact mat vertical jump heights and those measured using the criterion device.”
MethodRoundtable Discussion: Machines Versus Free Weights
Haff, G. G. (2000) · Strength and conditioning journal · doi:10.1519/1533-4295(2000)022<0070:vjtacr>2.0.co;2 · Cited by 45 · cited 1×
“The fact that the belt mat also proved to be a valid device was perhaps more surprising, although it has been argued previously that a belt mat is better than other traditional vertical jump devices (jump and reach and contact mat; Klavora, 2000).”
Background(1994) · doi:10.1519/1073-6840(1994)016<0020:dempif>2.3.co;2 · cited 2×
“Given that muscular power is an important determinant of performance in many individual and team sports (Newton & Kraemer, 1994), and a critical factor in the mobility and the functional capacity of injured or aged individuals, valid measures of vertical jump performance are desirable.”
Background
Cited by
Petrigna, L., Karsten, B., Marcolin, G., Paoli, A., D’Antona, G., Palma, A., & Bianco, A. (2019) · Frontiers in Physiology · doi:10.3389/fphys.2019.01384 · Cited by 195
Identifying a Test to Monitor Weightlifting Performance in Competitive Male and Female Weightlifters
Travis, S. K., Goodin, J. R., Beckham, G. K., & Bazyler, C. D. (2018) · Sports · doi:10.3390/sports6020046 · Cited by 36
“Therefore, an analysis with more robust instrumentation is needed to confirm these relationships [17,18].”
BackgroundAlthouse, D., Weeks, C., Spencer, S. B., Park, J., Thompson, B. J., & Louder, T. (2025) · Signals · doi:10.3390/signals6010011 · Cited by 3
Metadata
- Authors
- Buckthorpe, M., Morris, J., & Folland, J. P.
- Venue
- Journal of Sports Sciences
- Publisher
- Informa UK Limited
- Published
- 2012-01
- Volume
- 30
- Issue
- 1
- Pages
- 63-69
- ISSN
- 0264-0414 (ISSN-L)
- 1466-447X
- OpenAlex
- W2164928634
- Cited by
- 198
- References
- 22
- FWCI
- 3.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.