CoChat

Effects of Inertial Measurement Unit Location on the Validity of Vertical Acceleration Time-Series Data and Jump Height in Countermovement Jumping

Open access

The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.

Abstract

Inertial measurement units (IMUs) are an example of practical technology for measuring countermovement jump (CMJ) performance, but there is a need to enhance their validity. One potential strategy to achieve this is advancing the literature on IMU placement. Many studies opt to position a single IMU on anatomical landmarks rather than determining placement based on anthropometric principles, despite the knowledge that linear mechanics act through the segmental centers of mass of the human body. The purpose of this study was to evaluate the impact of positioning IMU sensors to approximate the trunk and lower-extremity segmental centers of mass on the validity of vertical acceleration measurements and jump height (JH) estimation during CMJs. Thirty young adults (female n = 10, 21.3 (3.8) years, 166.1 (4.1) cm, 67.6 (11.3) kg; male n = 20, 22.0 (2.6) years, 179.2 (6.4) cm, 83.5 (17.1) kg) from a university setting participated in the study. Seven IMUs were positioned at the approximate centers of mass of the trunk, thighs, shanks, and feet. Using data from these sensors, 15 whole-body center of mass models were developed, including 1-, 2-, 3-, and 4-segment configurations derived from the trunk and three lower-body segments. The root mean square error (RMSE) of vertical acceleration was calculated for each IMU model by comparing its data against vertical acceleration measurements obtained from a force platform. JH estimates were calculated using the take-off velocity method and compared across IMU models and the force platform to evaluate for systematic bias. RMSE and JH values from the best-performing 1-, 2-, 3-, and 4-segment IMU models were analyzed for main effects using one-way analyses of variance. The best performing 2-segment (trunk and shanks; RMSE = 2.1 ± 1.3 m × s−2) and 3-segment (trunk, thighs, and feet; RMSE = 2.0 ± 1.2 m × s−2) IMU models returned significantly lower RMSE values compared to the 1- segment (trunk; RMSE = 3.0 ± 1.4 m × s−2) model (p = 0.021–0.041). No systematic bias was detected between the JH estimates derived from the best-performing IMU models and those obtained from the force platform (p = 0.91–0.99). Positioning multiple IMU sensors to approximate segmental centers of mass significantly improved the validity of vertical acceleration time-series data from CMJs. The findings highlight the importance of anthropometric-based IMU placement for enhancing measurement accuracy without introducing systematic bias.

Overview

Integrity signals

Registry

Crossref · 10.3390/signals6010011

Cites

35 of 35 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 35 references

Research works printed but not linked: 1

  1. Winter, D. (1990). Biomechanics and Motor Control of Human Movement, John Wiley & Sons. [4th ed.].

Cited by

See all 3

Metadata

Authors
Althouse, D., Weeks, C., Spencer, S. B., Park, J., Thompson, B. J., & Louder, T.
Affiliations
  • Utah State University (US)
  • University of Colorado Anschutz (US)
Corresponding author
Louder, Talin
Venue
Signals
Publisher
MDPI AG
Published
2025-03-03
Volume
6
Issue
1
Pages
11
ISSN
2624-6120 (ISSN-L)
OpenAlex
W4408115957
Cited by
3
References
33
Citations by year
2026: 3
FWCI
3.05
Type
journal article
Language
en
Open access
Locations
  • Signals (publishedVersion, cc-by)
  • Digital Commons - USU (Utah State University) (submittedVersion, cc-by)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Topics
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
  • Physical Sciences › Engineering › Biomedical Engineering › Sports Dynamics and Biomechanics
  • Health Sciences › Health Professions › Physical Therapy, Sports Therapy and Rehabilitation › Physical Education and Training Studies
Keywords
inertial measurement unit, countermovement jump, jump height, vertical acceleration, take-off velocity, wearable sensors, measurement validity, young adults, sex differences, limb dominance, limb length discrepancy

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effects of Inertial Measurement Unit Location on the Validity of Vertical Acceleration Time-Series Data and Jump Height in Countermovement Jumping. https://app.cochat.ai/papers/10.3390/signals6010011
The paper
Althouse, D., Weeks, C., Spencer, S. B., Park, J., Thompson, B. J., & Louder, T. (2025). Effects of Inertial Measurement Unit Location on the Validity of Vertical Acceleration Time-Series Data and Jump Height in Countermovement Jumping. Signals. https://doi.org/10.3390/signals6010011

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.