The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
The validity and reliability of an iPhone app for measuring vertical jump performance
Abstract
The purpose of this investigation was to analyse the concurrent validity and reliability of an iPhone app (called: My Jump) for measuring vertical jump performance. Twenty recreationally active healthy men (age: 22.1 ± 3.6 years) completed five maximal countermovement jumps, which were evaluated using a force platform (time in the air method) and a specially designed iPhone app. My jump was developed to calculate the jump height from flight time using the high-speed video recording facility on the iPhone 5 s. Jump heights of the 100 jumps measured, for both devices, were compared using the intraclass correlation coefficient, Pearson product moment correlation coefficient (r), Cronbach's alpha (α), coefficient of variation and Bland-Altman plots. There was almost perfect agreement between the force platform and My Jump for the countermovement jump height (intraclass correlation coefficient = 0.997, P < 0.001; Bland-Altman bias = 1.1 ± 0.5 cm, P < 0.001). In comparison with the force platform, My Jump showed good validity for the CMJ height (r = 0.995, P < 0.001). The results of the present study showed that CMJ height can be easily, accurately and reliably evaluated using a specially developed iPhone 5 s app.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The validity and reliability of the application has previously been proven [24].”
From Acute effects of brief mindfulness intervention coupled with carbohydrate ingestion to re-energize soccer players: a randomized crossover trial. (2020) · cites this paper as [24]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
A simple method for measurement of mechanical power in jumping
Bosco, C., Luhtanen, P., & Komi, P. V. (1983) · European Journal of Applied Physiology · doi:10.1007/bf00422166 · Cited by 1,717
JOURNAL OF SPORTS SCIENCE & MEDICINE
Kallinen, M. (2005) · Cited by 1,480
Reliability and Factorial Validity of Squat and Countermovement Jump Tests
Marković, G., Dizdar, D., Jukić, I., & Cardinale, M. (2004) · The Journal of Strength and Conditioning Research · doi:10.1519/00124278-200408000-00028 · Cited by 1,132
Velocity Loss as an Indicator of Neuromuscular Fatigue during Resistance Training
SÁNCHEZ-MEDINA, L., & GONZÁLEZ-BADILLO, J. J. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e318213f880 · Cited by 852
Validity and Reliability of Optojump Photoelectric Cells for Estimating Vertical Jump Height
Item‐Glatthorn, J. F., Gouge, S., Nussbaumer, S., Stauffacher, S., Impellizzeri, F. M., & Maffiuletti, N. A. (2010) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0b013e3181ccb18d · Cited by 704
Cross-validation of three jump power equations
Sayers, S. P., HARACKIEWICZ, D. V., Harman, E. A., Frykman, P., & Rosenstein, M. T. (1999) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199904000-00013 · Cited by 597
Measuring and Influencing Physical Activity with Smartphone Technology: A Systematic Review
Roig, J. B., Gilson, N. D., Puig-Ribera, A. M., Contreras-Espinosa, R. S., & Trost, S. G. (2014) · Sports Medicine · doi:10.1007/s40279-014-0142-5 · Cited by 554
Moir, G. L. (2008) · Measurement in Physical Education and Exercise Science · doi:10.1080/10913670802349766 · Cited by 356
Alemdaroğlu, U. (2012) · Journal of Human Kinetics · doi:10.2478/v10078-012-0016-6 · Cited by 278
Research works printed but not linked: 2
- Fry A. C., 2006, Journal of Strength & Conditioning Research, 20, 861
- Markovic G., 2004, Journal of Strength & Conditioning Research, 18, 551
Cited by
Sorted by citations
Items 201–300 of 613
Brahim, M. B., Sal-de-Rellán, A., García-Valverde, A., Yasin, H., & González, J. R. (2023) · PeerJ · doi:10.7717/peerj.15803 · Cited by 9
Gómez, E., Atef, H., Elsayed, S. H., Zakaria, H. M., Navarro, M., & Sulé, E. (2023) · Medicine · doi:10.1097/md.0000000000034626 · Cited by 7
“995).[28] (d) Vertical jump performance with arm impulse (cm) was measured using the Counter Movement Jumping Abalakov Test.”
MethodRibeiro, J. A., Schuch, F. B., Tonello, L., Vargas, K. F. M., de Oliveira-Junior, S. A., Müller, P. D. T., & Boullosa, D. A. (2024) · Frontiers in Psychiatry · doi:10.3389/fpsyt.2024.1356559 · Cited by 13
Bassa, E. I., Lola, A. C., Melliou, A., Prassa, M., Stavropoulou, G., & Ziogas, N. K. (2024) · Pediatric Exercise Science · doi:10.1123/pes.2024-0024 · Cited by 16
Noorbhai, H., Chhaya, M. M. A., & Noakes, T. D. (2016) · Cogent Medicine · doi:10.1080/2331205x.2016.1214338 · Cited by 9
Audio-Based System for Automatic Measurement of Jump Height in Sports Science
Pueo, B., López, J. J., & Jiménez-Olmedo, J. M. (2019) · Sensors · doi:10.3390/s19112543 · Cited by 10
“In the case of landing with one foot slightly delayed with respect to the other, the algorithm to be developed should trigger the landing event when the first foot touches the ground, as this is same criterion used in force plates, jump mats, and observational instruments [12].”
BackgroundSmartJump: A Continuous Jump Detection Framework on Smartphones
Li, Y., Peng, X., Zhou, G., & Zhao, H. (2020) · IEEE Internet Computing · doi:10.1109/mic.2020.2969610 · Cited by 9
Barrajón, J. P., & Juan, A. F. S. (2020) · Sustainability · doi:10.3390/su12062312 · Cited by 9
“Nowadays, it is more and more common to find smartphone sports applications (APPs) specifically for velocity lifting analysis [14] or to assess vertical jumping [18].”
BackgroundToro-Román, V., Ferrer-Ramos, P., Illera-Domínguez, V., Buxadé, C. P.-C., & Fernández-Valdés, B. (2024) · Frontiers in Physiology · doi:10.3389/fphys.2024.1347093 · Cited by 12
Advancing Field-Based Vertical Jump Analysis: Markerless Pose Estimation vs. Force Plates
Aleksić, J., Mesaroš, D., Kanevsky, D., Knežević, O. M., Čabarkapa, D., Faj, L., & Mirkov, D. M. (2024) · Life · doi:10.3390/life14121641 · Cited by 10
Asymmetry of the Single Leg Jump and Lateral Shuffle Performance in Pre-Juvenile Basketball Players
Lyu, M., Chen, Z., Deng, S., Ding, L., Han, J., Bishop, C. J., & Li, Y. (2025) · Journal of Human Kinetics · doi:10.5114/jhk/196315 · Cited by 8
“The CMJ and the SLCMJ were measured using a phone app (MYJUMP2), which has been proven to be a reliable jump measuring tool (Balsalobre-Fernández et al., 2015; Bishop et al., 2022a).”
Martín, L. T., González, J. R., Ramírez‐Campillo, R., Chaabène, H., & Sánchez-Sánchez, J. (2021) · Research in Sports Medicine · doi:10.1080/15438627.2021.2010205 · Cited by 10
Tallis, J. A., Morris, R. O., Duncan, M. J., Eyre, E. L. J., & Guimarães‐Ferreira, L. (2023) · Sports · doi:10.3390/sports11060117 · Cited by 8
demir, I. C., & Çilli, M. (2018) · Online Türk Sağlık Bilimleri Dergisi · doi:10.26453/otjhs.364026 · Cited by 8
Navarro‐Santana, M. J., Albert-Lucena, D., Gómez-Chiguano, G. F., Plaza‐Manzano, G., Fernández‐de‐las‐Peñas, C., Cleland, J. A., Pérez-Silvestre, Á., & Asín‐Izquierdo, I. (2019) · Physical Therapy in Sport · doi:10.1016/j.ptsp.2019.09.002 · Cited by 8
Caffeine improves performance but not duration of the countermovement jump phases
Lago-Rodríguez, Á., Jiménez, P. J., Bailey, S. J., & Domínguez, R. (2021) · The Journal of Sports Medicine and Physical Fitness · doi:10.23736/s0022-4707.20.11099-5 · Cited by 8
Mansfield, C. J., Rethman, K., Stephens, J. A., Stasi, S. D., VanEtten, L., & Briggs, M. S. (2022) · The Knee · doi:10.1016/j.knee.2022.04.010 · Cited by 8
Santos, E. R. T., de Salles, B. F., Dias, I. B. F., Junior, R. F. S., & Willardson, J. M. (2022) · International journal of exercise science · doi:10.70252/paqb8351 · Cited by 8
My Jump 2 Mobil Uygulamasının Geçerlilik ve Güvenilirlik Analizi
Gür, F., & Ayan, V. (2023) · Spor Bilimleri Araştırmaları Dergisi · doi:10.25307/jssr.1192168 · Cited by 8
Moreno-Pérez, J. A., Ruiz‐García, I., Navarro-Marchal, I., López-Ruiz, N., Gómez-López, P. J., Palma, A. J., & Carvajal, M. A. (2023) · Sensors · doi:10.3390/s23136022 · Cited by 11
“Myotest accelerometric system (Myotest SA, Sion, Switzerland) [33] 500 Hz - 7.24 ( ± 2.82) cm ± 8 g 0.98 x-BIMU Bluetooth Kit (x-io Technologies Limited, UK) [49] 256 Hz - 5.5 cm ± 16 g 0.90 This system 200 Hz Data to APP via Bluetooth − 0.5 cm ± 16 g 0.96 The technique used for the jumps was the CMJ (counter-movement…”
BackgroundInfluentialŞentürk, D., Yüksel, O., & Akyıldız, Z. (2024) · Proceedings of the Institution of Mechanical Engineers Part P Journal of Sports Engineering and Technology · doi:10.1177/17543371241246439 · Cited by 8
Hohenauer, E., Clarys, P., Baeyens, J., & Clijsen, R. (2017) · Journal of Visualized Experiments · doi:10.3791/55612 · Cited by 8
Can IPhone Application Be Used To Determine Vertical Jump Performance?
Kaymakçı, A. T., Çoban, G. Ö., & Gelen, E. (2018) · International Journal of Sport Exercise & Training Sciences · doi:10.18826/useeabd.437153 · Cited by 8
TAMURA, T., & Maeda, Y. (2017) · Springer eBooks · doi:10.1007/978-3-319-69362-0_6 · Cited by 11
The influence of anthropometric parameters in track and field curve sprint
Bonato, M., Bizzozero, S., Filipas, L., & Torre, A. L. (2023) · The Journal of Sports Medicine and Physical Fitness · doi:10.23736/s0022-4707.23.15056-0 · Cited by 7
Unalmis, Y., & Müniroğlu, S. (2023) · Sports Medicine and Health Science · doi:10.1016/j.smhs.2023.09.010 · Cited by 7
“48 When the literature is examined, valid and reliable results have been obtained in the studies conducted to determine the validity and reliability of the My Jump 2 application.”
MethodBrahim, M. B., Sal-de-Rellán, A., Yasin, H., & Hernaiz-Sánchez, A. (2023) · PLoS ONE · doi:10.1371/journal.pone.0294867 · Cited by 7
Validity and Reliability of My Jump 2 App for Jump Performance in Judo Players
Soares, D. P., Rodrigues, C., Lourenço, J., & Dias, A. (2023) · The Open Sports Sciences Journal · doi:10.2174/1875399x-v16-e230714-2023-6 · Cited by 7
Kinematic Mobile Drop Jump Analysis at Different Heights Based on a Smartphone Inertial Sensor
Angulo, Á. M., Galán-Mercant, A., & Cuesta‐Vargas, A. (2020) · Journal of Human Kinetics · doi:10.2478/hukin-2019-0131 · Cited by 7
“However, it did not use the inertial sensor of the smartphone to analyse the jump; the phone camera was used instead (Balsalobre-Fernández et al., 2015; GallardoFuentes et al., 2016).”
MethodEffects of a Gluteal Muscles Specific Exercise Program on the Vertical Jump
Gallego‐Izquierdo, T., Vidal-Aragón, G., Calderón-Corrales, P., Acuña, Á., Achalandabaso‐Ochoa, A., Aibar‐Almazán, A., Martínez‐Amat, A., & Pecos‐Martín, D. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17155383 · Cited by 7
“Finally, although ‘My Jump 2’ has been validated [19], the results depend on the human eye when selecting the take-off and landing photographs, as opposed to force platforms (the gold standard method), which perform a direct measurement of take-off and landing.”
BackgroundMarchese, V. G., Rock, K., York, T., Ruble, K., & Gray, V. L. (2022) · Frontiers in Pediatrics · doi:10.3389/fped.2022.891650 · Cited by 8
“Although laboratory-based measurements of lower extremity joint torques during a jump and jump height in this study are challenging to use clinically, previous studies have demonstrated concurrent validity and reliability of 3D motion analysis with clinically-available measurements of height using an iPhone app in adu…”
MethodPonce, T., Mainenti, M. R. M., Cardoso, E. L., de Barros, T. R., Salerno, V. P., & Vaisman, M. (2022) · Journal of Endocrinological Investigation · doi:10.1007/s40618-022-01913-4 · Cited by 7
Villalón-Gasch, L., Penichet-Tomás, A., Olaya-Cuartero, J., & Jiménez-Olmedo, J. M. (2023) · Applied Sciences · doi:10.3390/app13053151 · Cited by 7
Defining and quantifying fatigue in the rugby codes
Naughton, M. R., Scott, T. J., Weaving, D., Solomon, C., & McLean, S. G. (2023) · PLoS ONE · doi:10.1371/journal.pone.0282390 · Cited by 10
“Conversely, in the present study, monitoring fatigue through the plyometric pushup, knee extension isokinetic dynamometry, and jump height measured by a validated smart-phone application [48] were considered of low importance and/or difficult to implement.”
BackgroundBecerra-Patiño, B. A., Reina, C. J., Martínez-Benitez, C. F., Uribe, J. D. P., Montilla-Valderrama, V., Cárdenas-Contreras, S., Castro-Malaver, M. A., Murcia, J. J. V., & Martínez, J. (2023) · Retos · doi:10.47197/retos.v51.100442 · Cited by 7
Montoye, A. H. K., & Mitrzyk, J. R. (2018) · Measurement in Physical Education and Exercise Science · doi:10.1080/1091367x.2018.1539739 · Cited by 7
Schärer, C., von Siebenthal, L., Lomax, I., Gross, M., Taube, W., & Hübner, K. (2019) · Applied Sciences · doi:10.3390/app9193975 · Cited by 7
“The validity and reliability of 2D analysis were deemed sufficient for measuring the flight time and height of vertical jumps, when compared to optical measurement systems (Opto Jump, Microgate, I) [8] or to a force plate [9].”
BackgroundMethodResultKey performance indicators in Tour de France sailing
Philippe, K., Paillard, T., Dubois, R., Maurelli, O., & Prioux, J. (2020) · Journal of Sports Sciences · doi:10.1080/02640414.2020.1851925 · Cited by 7
“A validated and reliable smartphone application (Balsalobre-Fernandez et al., 2015) was used for lateral video analysis.”
MethodPueo, B., Jiménez-Olmedo, J. M., Penichet-Tomás, A., & Bernal-Soriano, M. C. (2018) · Journal of Physical Education and Sport · doi:10.7752/jpes.2018.02121 · Cited by 7
“The level of scattered data points in Bland-Altman plots of previous studies facing experienced raters are very similar to that of the present study (Balsalobre-Fernandez et al., 2015).”
ResultMonitoring Bar Velocity to Quantify Fatigue in Resistance Training
Moura, R. E., da Silva, R. F. B., Gomes, L. M. D. S., da Silva, J. L. R., Henrique, R. D. S., Sousa, F. A. D. B., & Fonseca, F. D. S. (2024) · International Journal of Sports Medicine · doi:10.1055/a-2316-7966 · Cited by 7
Peng, Y., Sun, S., Wang, Y., Qin, Y. X., & Qin, D. (2024) · PeerJ · doi:10.7717/peerj.17658 · Cited by 10
J, L., Shepherd, A. I., Corbett, J., Gruet, M., Connett, G. J., Allenby, M. I., Legg, J. P., Daniels, T. W. V., Urquhart, D. S., & SAYNOR, Z. L. (2025) · Pediatric Pulmonology · doi:10.1002/ppul.71044 · Cited by 7
“The “ MyJump2 ” application has proven valid and reliable [28, 29] for calculating jump height via high ‐ speed video [30].”
Paulauskas, R., Pundzevičius, V., & Figueira, B. (2025) · Scientific Reports · doi:10.1038/s41598-025-99647-9 · Cited by 6
“An iPhone 11 Pro, equipped with the MyJump app 35 , recorded the jumps at 240 frames per second.”
InfluentialWang, P., Lyu, M., Geng, N., Wu, Z., Ren, X., Kozinc, Ž., Kons, R. L., Šarabon, N., & Miao, X. (2025) · Frontiers in Physiology · doi:10.3389/fphys.2025.1587719 · Cited by 6
Abdioğlu, M., Mor, A., Alexe, D. I., Todor, R. M., Panaet, E. A., Alexe, C. I., & Akça, F. (2025) · Frontiers in Nutrition · doi:10.3389/fnut.2025.1608893 · Cited by 6
Lyu, M., Pappas, E., Ding, L., Qian, H., Huang, J., Farragher, J. B., Ganderton, C. L., Xenos, S., Lyu, J., & Han, J. (2025) · Frontiers in Physiology · doi:10.3389/fphys.2025.1704551 · Cited by 6
Borszcz, F. K., Vieira, M. T., Tramontin, A. F., Visentainer, L. H., & Costa, V. P. (2022) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000004231 · Cited by 6
“However, mobile applications are available for monitoring the vertical jump (2), which is more widely disseminated for this purpose (43,44).”
BackgroundSharp, A. P., Cronin, J. B., Neville, J., Diewald, S. N., Stolberg, M., Draper, N., & Walter, S. (2023) · International Journal of Kinesiology and Sports Science · doi:10.7575/aiac.ijkss.v.11n.3p.23 · Cited by 6
“Vertical jump data captured using mobile device applications have previously been compared with force platform data and shown high validity (r = 0.60-0.995) (Balsalobre-Fernandez et al., 2015; Carlos-Vivas et al., 2018; Driller et al., 2017; Gallardo-Fuentes et al., 2016; Stanton et al., 2017).”
MethodInfluentialBukry, S. A., Justine, M., Azidin, R. M. F. R., Azhar, N. I., Zolkafi, M. A. A., Lo, C. N., & Manaf, H. (2024) · Biomedical Human Kinetics · doi:10.2478/bhk-2024-0018 · Cited by 6
Videographic Variability of Triple and Quintuple Horizontal Hop Performance
Sharp, A. P., Neville, J., Diewald, S. N., Oranchuk, D. J., & Cronin, J. B. (2024) · Journal of Sport Rehabilitation · doi:10.1123/jsr.2023-0245 · Cited by 6
Concurrent Validity and Reliability of a Free Smartphone Application for Evaluation of Jump Height
Dias, A., Pires, P., Sant’Ana, L. D. O., Marques, P., Espada, M. C., Santos, F., Silva, E. J. D., Rebelo, A., & Teixeira, D. (2024) · Journal of Functional Morphology and Kinesiology · doi:10.3390/jfmk9030155 · Cited by 6
Montenegro-Bonilla, A. D., Pachón, S. D. R., Hernández-Beltrán, V., Gamonales, J. M., Rico-González, M., Pino‐Ortega, J., Arancibia, J. E. O., Sepulveda, R. A. Y., López‐Gil, J. F., & Becerra-Patiño, B. A. (2024) · Journal of Functional Morphology and Kinesiology · doi:10.3390/jfmk9040237 · Cited by 6
Lyu, M., Yin, M., Ding, L., Tang, R., Chen, Z., Deng, S., Zhong, Y., Li, Z., Nassis, G. P., & Li, Y. (2024) · Journal of Human Kinetics · doi:10.5114/jhk/190145 · Cited by 6
Izquierdo, I., García, L. G., González, J. R., Castillo, D., Sánchez-Sánchez, J., & Fernandez, A. R. (2021) · Cultura Ciencia y Deporte · doi:10.12800/ccd.v16i49.1264 · Cited by 6
Concurrent validity and reliability of an accelerometer to assess punching velocity in boxers
López‐Laval, I., Cirer-Sastre, R., PARIZA, J. L. A.-L. D., Corbi, F., Calleja-González, J., & Sitko, S. (2022) · Gazzetta Medica Italiana Archivio per le Scienze Mediche · doi:10.23736/s0393-3660.20.04425-3 · Cited by 6
Ruiz-Navarro, J. J., López‐Belmonte, Ó., Cuenca‐Fernández, F., Gay, A., & Arellano, R. (2024) · Journal of Human Kinetics · doi:10.5114/jhk/175824 · Cited by 6
“The countermovement jumps (CMJs) were analyzed using MyJump 2 (Balsalobre-Fernández et al., 2015).”
MethodParmar, A., Keenan, A., & Barry, G. (2020) · Physiological Measurement · doi:10.1088/1361-6579/abd236 · Cited by 6
Sánchez-Sánchez, J., Martín, L. T., Ramírez‐Campillo, R., Castillo, D., & González, J. R. (2022) · Research in Sports Medicine · doi:10.1080/15438627.2022.2079989 · Cited by 6
“This app has shown previously a strong validity (r = 0.99) and reliability (intraclass correlation coefficient = 0.99) for assessing CMJ height (Balsalobre-Fernández et al., 2015).”
BackgroundInfluentialBecerra-Patiño, B. A., Uribe, J. D. P., Martínez-Benitez, C. F., Ávila Martínez, J. D., & Sarria-Lozano, J. C. (2023) · Journal of Physical Education and Sport · doi:10.7752/jpes.2023.06181 · Cited by 6
Ojeda, Á. H., Beltrán-Inostroza, R., Yeomans‐Cabrera, M., & Torres-Banduc, M. A. (2024) · Isokinetics and Exercise Science · doi:10.3233/ies-240022 · Cited by 6
“Valid and reliable devices are now available to assess different manifestations of muscle force [11,12,13]; in most cases, these devices have been developed to transfer assessments from the laboratory to the field [8,14,15, 16].”
Nishioka, T., Yamaguchi, S., & Inami, T. (2024) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.2024-0063 · Cited by 5
Flórez-Gil, E., Mateus, N., Sampaio, J. E., & Abade, E. (2025) · Journal of Sports Sciences · doi:10.1080/02640414.2025.2467564 · Cited by 6
“For both jumping tests, the highest recorded jump was analyzed using the MyJump 2.0 smartphone application, which has demonstrated high validity ( r = 0.995, p ≤ 0.001) and reliability (ICC = 0.997, p ≤ 0.001) compared to force platforms (Balsalobre-Fernández et al., 2015).”
InfluentialVillanueva-Guerrero, Ó., Gonzalo‐Skok, Ó., Albalad-Aiguabella, R., & Mainer-Pardos, E. (2025) · Sports · doi:10.3390/sports13080263 · Cited by 5
Predicting injury risk in young female volleyball players through movement and jump assessments
Erol, M., Girginer, F. G., Seyhan, S., Açar, G., Çerit, G., Uzun, M., & Soylu, Ç. (2025) · Frontiers in Public Health · doi:10.3389/fpubh.2025.1658046 · Cited by 5
Peres, A. B., Espada, M. C., Santos, F., Robalo, R. A. M., Dias, A., Muñoz-Jiménez, J., Sancassani, A., Massini, D. A., & Filho, D. M. P. (2022) · Applied Sciences · doi:10.3390/app13010573 · Cited by 5
Rojas‐Valverde, D., Ugalde-Ramírez, A., Sánchez‐Ureña, B., & Gutiérrez-Vargas, R. (2019) · MHSALUD Revista en Ciencias del Movimiento Humano y Salud · doi:10.15359/mhs.17-1.2 · Cited by 5
Romero-García, D., Vaquero‐Cristóbal, R., Albaladejo-Saura, M., Esparza-Ros, F., & Sanz, J. M. M. (2023) · Applied Sciences · doi:10.3390/app13053012 · Cited by 5
Soga, T., Yamaguchi, S., Inami, T., Saito, H., Hakariya, N., Nakaichi, N., Shinohara, S., Akiyama, K., & Hirose, N. (2023) · International Journal of Sports Physical Therapy · doi:10.26603/001c.83936 · Cited by 5
JUMP ABILITY AND FORCE-VELOCITY PROFILE IN RHYTHMIC GYMNASTICS
de Sá, L. F. M., Leite, I. A. M. S., Batista, A., & Ávila-Carvalho, L. (2023) · Science of Gymnastics Journal · doi:10.52165/sgj.15.2.225-237 · Cited by 5
Jiménez-Daza, P., del Pino, L. T., Calleja-González, J., & de Villarreal, E. S. (2023) · Journal of Functional Morphology and Kinesiology · doi:10.3390/jfmk8040160 · Cited by 5
Soga, T., Yamaguchi, S., Inami, T., Saito, H., Hakariya, N., Nakaichi, N., Shinohara, S., Sasabe, K., Nakamura, H., Laddawong, T., et al. (2023) · International Journal of Sports Physical Therapy · doi:10.26603/001c.89271 · Cited by 5
Horcajo, J., & Mateos, R. (2024) · Journal of Sport and Exercise Psychology · doi:10.1123/jsep.2023-0079 · Cited by 5
Souron, R., Colard, J., Ruiz-Cárdenas, J. D., Beltran, A., Duché, P., & Gruet, M. (2024) · Movement & Sport Sciences - Science & Motricité · doi:10.1051/sm/2024001 · Cited by 5
Leite, I. A. M. S., Goethel, M. F., Fonseca, P., Vilas‐Boas, J. P., Ávila-Carvalho, L., Mochizuki, L., & da Conceição, F. A. (2024) · Applied Sciences · doi:10.3390/app14083191 · Cited by 5
Wang, Y., Wang, X., Luan, C., Shan, W., & Gong, L. (2024) · Frontiers in Sports and Active Living · doi:10.3389/fspor.2024.1405118 · Cited by 6
Effectiveness evaluation of whole-body electromyostimulation as a postexercise recovery method
Serrano, M. Á., Sevilla, A. I. P., & Veiga, Ó. L. (2018) · The Journal of Sports Medicine and Physical Fitness · doi:10.23736/s0022-4707.18.07737-x · Cited by 5
Comparison of Physical and Physiological Performance Features of Parkour and Gymnastics Athletes
Seyhan, S. (2019) · Journal of Education and Learning · doi:10.5539/jel.v8n2p111 · Cited by 5
Strength Asymmetries in Young Elite Sailors: Windsurfing, Optimist, Laser and 420 Classes
Caraballo, I., Casado-Rodríguez, F., Gutierrez‐Manzanedo, J. V., & Montesinos, J. L. G. (2021) · Symmetry · doi:10.3390/sym13030427 · Cited by 5
Oh, D.-S., Choi, Y.-H., Shim, Y.-J., Park, S.-H., & Lee, M.-M. (2020) · Baltic Journal of Health and Physical Activity · doi:10.29359/bjhpa.12.3.04 · Cited by 5
“Stanton and intour [10] analyzed smart phone-recorded jump performance with the application and when the results were compared with force plates, approximately 0.”
BackgroundMethodSellés, S., García-Jaén, M., Cortell-Tormo, J. M., & Cejuela, R. (2021) · Applied Sciences · doi:10.3390/app11073234 · Cited by 5
“Jump measurements were carried out by two experienced observers using the validated application “My jump®” [12].”
MethodValidity and Reliability of MyLift App in Determining 1-RM for Deadlift and Back Squat Exercises
Çetin, O. (2021) · European journal of human movement · doi:10.21134/eurjhm.2021.46.599 · Cited by 5
The adaptations in muscle architecture following whole body vibration training.
Çelik, E., Fιndıkoğlu, G., Kart, S. Ö., Akkaya, N., & Ertan, H. (2022) · PubMed Central · Cited by 5
Validity and reliability of ergonauta encoder to assess countermovement jump performance
Gheller, R. G., Kons, R. L., Külkamp, W., Pupo, J. D., & Detanico, D. (2023) · Proceedings of the Institution of Mechanical Engineers Part P Journal of Sports Engineering and Technology · doi:10.1177/17543371231171192 · Cited by 5
Normative values for physical fitness in children aged 11-17 in Kosovo
Berisha, M., & Çilli, M. (2018) · Pedagogics psychology medical-biological problems of physical training and sports · doi:10.15561/18189172.2018.0103 · Cited by 5
“In Squat and Vertical Jumping Tests, the “My Jump” application was used to determine the heights of the jumps [21].”
MethodÜnver, F., Kılıç-Toprak, E., Kılıç-Erkek, Ö., Korkmaz, H., Yasin, O., Oymak, B., Oskay, A., & Bor-Küçükatay, M. (2018) · Clinical Hemorheology and Microcirculation · doi:10.3233/ch-180402 · Cited by 5
“As such, with the development of an appropriate application (app), the phone has the potential to record high-speed videos and subsequently calculate jump height directly [18].”
Herdy, C. V., Galvão, P. V. M., Silva, G. V. D. L. C. E., Ramos, S. M., Junior, R. F. S., Pedrinelli, A., Mansur, S., Goncalves, D., & Paschalis, V. (2018) · Human Movement · doi:10.5114/hm.2018.76076 · Cited by 5
“Afterwards, the vertical jump test: countermovement jump with free arms was conducted with the iPhone 5s app My Jump, scientifically validated with the strength platform which is considered a gold standard for evaluating vertical jump [22].”
MethodBalsalobre‐Fernández, C. (2019) · Annals of Biomedical Engineering · doi:10.1007/s10439-019-02304-2 · Cited by 5
Effect of training in SSG on the ability to repeat sprints in young football players
Barba, F., Iturriaga, F. M. A., Borges-Hernández, P. J., Ruíz-Lara, E., & Perdomo, A. (2020) · Journal of Physical Education and Sport · doi:10.7752/jpes.2020.04242 · Cited by 5
Morin, J.-B., Jiménez‐Reyes, P., Brughelli, M., & Samozino, P. (2018) · doi:10.31236/osf.io/6nxyu · Cited by 5
Eken, Ö., Öncü, M., Kurtoğlu, A., Bozkurt, O., Türkmen, M., & Aldhahi, M. I. (2025) · Life · doi:10.3390/life15030422 · Cited by 6
“For analysis, the highest of the three recorded jump heights for each participant was selected [46].”
Automatic video analysis of countermovement jump performance using a single uncalibrated camera
Chiu, C., Chang, C.-C., Chiang, Y., & Chiang, C.-Y. (2025) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2025.112695 · Cited by 4
Li, Z., Zhi, P., Zhang, X., Bai, J., García‐Ramos, A., & Janicijevic, D. N. (2025) · Journal of Human Kinetics · doi:10.5114/jhk/201963 · Cited by 4
“Jump height significantly impacts sport ‐ specific performance, such as the success rate of jumping shots in basketball and the efficacy of spike and block manoeuvres in volleyball (Nishiumi and Hirose, 2024; Okazaki et al., 2015; Riemann et al., 2024; Ziv and Lidor, 2010).”
Sansone, P., Gasperi, L., Gómez, M., & Tessitore, A. (2024) · The Journal of Sports Medicine and Physical Fitness · doi:10.23736/s0022-4707.24.16026-4 · Cited by 4
Noutsos, K. S., Meletakos, P., Kepesidou, M., & Bogdanis, G. C. (2024) · Journal of Functional Morphology and Kinesiology · doi:10.3390/jfmk9040204 · Cited by 4
Sanders, G. J., Skodinski, S., & Peacock, C. A. (2025) · Translational Sports Medicine · doi:10.1155/tsm2/7216781 · Cited by 4
Agar-Newman, D. J., Tsai, M., & Klimstra, M. D. (2020) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000003581 · Cited by 4
“The 3-factor model has led to the validation of smartphone applications that provide a simple way to test and profile athletes (3,5).”
MethodBukry, S. A., Azidin, R. M. F. R., Justine, M., & Manaf, H. (2022) · Annals of Applied Sport Science · doi:10.52547/aassjournal.1033 · Cited by 4
“88) and absolute reliability (CV<10%) (22).”
Araujo, S., Nascimento, L. R., & Felício, L. R. (2023) · The Knee · doi:10.1016/j.knee.2023.04.012 · Cited by 4
Cayetano, A. R., Ramos, S. L., Ollero, D. E., & Muñoz, S. P. (2023) · Retos · doi:10.47197/retos.v50.97320 · Cited by 4
“…la cual ha sido validada y verificada a través de diferentes estudios que han comprobado las mediciones de esta aplicación móvil en los test de salto, test de velocidad, test de cambios de dirección y test de movilidad (Balsalobre et al., 2015; Balsalobre et al., 2019a; Balsalobre et al., 2019b).”
How Does the Jumping Performance Differs between Acrobatic and Rhythmic Gymnasts?
Leite, I. A. M. S., Goethel, M. F., da Conceição, F. A., & Ávila-Carvalho, L. (2023) · Biomechanics · doi:10.3390/biomechanics3040037 · Cited by 4
“Regarding the use of MyJump2 , the major drawback is that videos are recorded at 120 Hz, so there is a chance that the take-off and/or the landing frame is not recorded [35], although we did not find any case where these frames were not recorded.”
Method
Metadata
- Authors
- Balsalobre-Fernández, C., Glaister, M., & Lockey, R. A.
- Affiliations
- Department of Physical Education, Sport and Human Movement, Autonomous University of Madrid, Madrid, Spain
- St Mary's University Twickenham London (GB)
- ORCID
- Glaister, Mark
- Venue
- Journal of Sports Sciences
- Publisher
- Informa UK Limited
- Published
- 2015-01-02
- Volume
- 33
- Issue
- 15
- Pages
- 1574-1579
- ISSN
- 0264-0414 (ISSN-L)
- 1466-447X
- OpenAlex
- W2013598477
- Cited by
- 621
- References
- 31
- Citations by year
- 2026: 57 · 2025: 69 · 2024: 89 · 2023: 90 · 2022: 63 · 2021: 58 · 2020: 64 · 2019: 38 · 2018: 55 · 2017: 22 · 2016: 9 · 2015: 7
- FWCI
- 31.86
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Sports Sciences (publishedVersion)
- PubMed (publishedVersion)
- St Mary's University Repository (St Mary's University Twickenham London) (acceptedVersion)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
- Health Sciences › Health Professions › Physical Therapy, Sports Therapy and Rehabilitation › Physical Education and Training Studies
- Physical Sciences › Engineering › Biomedical Engineering › Sports Dynamics and Biomechanics
- Keywords
- vertical jump, countermovement jump, iOS app, concurrent validity, test-retest reliability, high-speed video, jump height measurement, force plate
- MeSH terms
- Humans, Male, Movement, Reproducibility of Results, Lower Extremity, Athletic Performance, Young Adult, Mobile Applications
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review