Non-wear or sleep? Evaluation of five non-wear detection algorithms for raw accelerometer data
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Detection of non-wear periods is an important step in accelerometer data processing. This study evaluated five non-wear detection algorithms for wrist accelerometer data and two rules for non-wear detection when non-wear and sleep algorithms are implemented in parallel. Non-wear algorithms were based on the standard deviation (SD), the high-pass filtered acceleration, or tilt angle. Rules for differentiating sleep from non-wear consisted of an override rule in which any overlap between non-wear and sleep was deemed non-wear; and a 75% rule in which non-wear periods were deemed sleep if the duration was < 75% of the sleep period. Non-wear algorithms were evaluated in 47 children who wore an ActiGraph GT3X+ accelerometer during school hours for 5 days. Rules for differentiating sleep from non-wear were evaluated in 15 adults who wore a GeneActiv Original accelerometer continuously for 24 hours. Classification accuracy for the non-wear algorithms ranged between 0.86-0.95, with the SD of the vector magnitude providing the best performance. The override rule misclassified 37.1 minutes of sleep as non-wear, while the 75% rule resulted in no misclassification. Non-wear algorithms based on the SD of the acceleration signal can effectively detect non-wear periods, while application of the 75% rule can effectively differentiate sleep from non-wear when examined concurrently.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Physical Activity in the United States Measured by Accelerometer
TROIANO, R. P., BERRIGAN, D., DODD, K. W., MÂSSE, L. C., TILERT, T., & MCDOWELL, M. (2008) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31815a51b3 · Cited by 7,638 · cited 1×
“…counts ranging between 20 – 90 minutes in duration as an indicator of non-wear time (Choi, Liu, Matthews, & Buchowski, 2011; Choi, Ward, Schnelle, & Buchowski, 2012; Esliger, Copeland, Barnes, & Tremblay, 2005; Evenson & Terry, 2009; Jaeschke et al., 2017; Masse et al., 2005; Troiano et al., 2008).”
Tremblay, M. S., Carson, V., Chaput, J.-P., Connor Gorber, S., Dinh, T., Duggan, M., Faulkner, G., Gray, C. E., Gruber, R., Janson, K., et al. (2016) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2016-0151 · Cited by 2,024 · cited 1×
“On the weight of this evidence, public health organisations have issued 24-hour movement guidelines recommending a healthy combination of physical activity, screen time, and sleep across the day (Okely et al., 2017; Tremblay et al., 2016; World Health Organization, 2019).”
BackgroundValidation of Accelerometer Wear and Nonwear Time Classification Algorithm
CHOI, L., LIU, Z., MATTHEWS, C. E., & BUCHOWSKI, M. S. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181ed61a3 · Cited by 1,804
Doherty, A., Jackson, D., Hammerla, N., Plötz, T., Olivier, P., Granat, M. H., White, T., van Hees, V. T., Trenell, M. I., Owen, C. G., et al. (2017) · PLOS ONE · doi:10.1371/journal.pone.0169649 · Cited by 1,250
A novel, open access method to assess sleep duration using a wrist-worn accelerometer
van Hees, V. T., Sabia, S., Anderson, K. N., Denton, S. J., Oliver, J., Catt, M., Abell, J. G., Kivimäki, M., Trenell, M. I., & Singh-Manoux, A. (2015) · PLOS ONE · doi:10.1371/journal.pone.0142533 · Cited by 744 · cited 3×
“The fi rst algorithm (VH_30/80), developed by Van Hees et al. (van Hees et al., 2013, 2011), identi fi ed non-wear periods using the standard deviation (SD) and range of the acceleration signal along the x, y, and z axes recorded for 60-minute windows, with a 45-minute overlap.”
MethodField evaluation of a random forest activity classifier for wrist-worn accelerometer data
Pavey, T. G., Gilson, N. D., Gomersall, S. R., Clark, B., & Trost, S. G. (2017) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2016.06.003 · Cited by 174 · cited 1×
“Dataset 2 comprised accelerometer data from a study in Queensland, Australia evaluating the performance of a wrist-worn accelerometer activity classi fi cation model in free living adults (Pavey, Gilson, Gomersall, Clark, & Trost, 2017).”
MethodSelf-citationIdentifying Children’s Nocturnal Sleep Using 24-h Waist Accelerometry
BARREIRA, T. V., SCHUNA, J. M., MIRE, E. F., KATZMARZYK, P. T., CHAPUT, J.-P., LEDUC, G., & TUDOR-LOCKE, C. (2015) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000486 · Cited by 163 · cited 1×
“…et al. (van Hees et al., 2015, 2018) in the development and evaluation of the sleep algorithm implemented in the current study; and has been used in other studies evaluating the validity of sleep-wake period detection algorithms (Barreira et al., 2015; Kinder et al., 2012; van Hees et al., 2018).”
Method
Cited by
Stamatakis, E., Ahmadi, M. N., Gill, J. M. R., Thøgersen-Ntoumani, C., Gibala, M. J., Doherty, A., & Hamer, M. (2022) · Nature Medicine · doi:10.1038/s41591-022-02100-x · Cited by 336
Self-citationdel Pozo Cruz, B., Ahmadi, M. N., Lee, I.-M., & Stamatakis, E. (2022) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2022.4000 · Cited by 265
Self-citationVigorous physical activity, incident heart disease, and cancer: how little is enough?
Ahmadi, M. N., Clare, P. J., Katzmarzyk, P. T., del Pozo Cruz, B., Lee, I. M., & Stamatakis, E. (2022) · European Heart Journal · doi:10.1093/eurheartj/ehac572 · Cited by 175
“Participants returned the devices by mail and the data were calibrated and non-wear periods were identified according to standard procedures.(14,15) Monitoring days were considered valid if wear time was greater than 16 h.”
MethodSelf-citationAhmadi, M. N., Hamer, M., Gill, J. M. R., Murphy, M., Sanders, J. P., Doherty, A., & Stamatakis, E. (2023) · The Lancet Public Health · doi:10.1016/s2468-2667(23)00183-4 · Cited by 172
Self-citation
Metadata
- Authors
- Ahmadi, M. N., Nathan, N., Sutherland, R., Wolfenden, L., & Trost, S. G.
- Venue
- Journal of Sports Sciences
- Publisher
- Informa UK Limited
- Published
- 2019-12-11
- Volume
- 38
- Issue
- 4
- Pages
- 399-404
- ISSN
- 0264-0414 (ISSN-L)
- 1466-447X
- OpenAlex
- W2994817867
- Cited by
- 113
- References
- 7
- FWCI
- 3.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Non-wear or sleep? Evaluation of five non-wear detection algorithms for raw accelerometer data. https://app.cochat.ai/papers/10.1080/02640414.2019.1703301
- The paper
- Ahmadi, M. N., Nathan, N., Sutherland, R., Wolfenden, L., & Trost, S. G. (2020). Non-wear or sleep? Evaluation of five non-wear detection algorithms for raw accelerometer data. Journal of Sports Sciences. https://doi.org/10.1080/02640414.2019.1703301
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.