Abstract
The potential of a static micromixer for the production of protein-loaded biodegradable polymeric microspheres by a modified solvent extraction process was examined. The mixer consists of an array of microchannels and features a simple set-up, consumes only very small space, lacks moving parts and offers simple control of the microsphere size. Scale-up from lab bench to industrial production is easily feasible through parallel installation of a sufficient number of micromixers ('number-up'). Poly(lactic-co-glycolic acid) microspheres loaded with a model protein, bovine serum albumin (BSA), were prepared. The influence of various process and formulation parameters on the characteristics of the microspheres was examined with special focus on particle size distribution. Microspheres with monomodal size distributions having mean diameters of 5-30 micro m were produced with excellent reproducibility. Particle size distributions were largely unaffected by polymer solution concentration, polymer type and nominal BSA load, but depended on the polymer solvent. Moreover, particle mean diameters could be varied in a considerable range by modulating the flow rates of the mixed fluids. BSA encapsulation efficiencies were mostly in the region of 75-85% and product yields ranged from 90-100%. Because of its simple set-up and its suitability for continuous production, static micromixing is suggested for the automated and aseptic production of protein-loaded microspheres.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Langer, R. (1990) · Science · doi:10.1126/science.2218494 · Cited by 1,778
Cited by
Micromixers—a review on passive and active mixing principles
Hessel, V., Löwe, H., & Schönfeld, F. (2005) · Chemical Engineering Science · doi:10.1016/j.ces.2004.11.033 · Cited by 1,479
Freitas, S., Merkle, H. P., & Gander, B. (2005) · Journal of Controlled Release · doi:10.1016/j.jconrel.2004.10.015 · Cited by 923
Self-citationThe Synthesis and Assembly of Polymeric Microparticles Using Microfluidics
Dendukuri, D., & Doyle, P. S. (2009) · Advanced Materials · doi:10.1002/adma.200803386 · Cited by 654
Issues in long-term protein delivery using biodegradable microparticles
Ye, M., Kim, S., & Park, K. (2010) · Journal of Controlled Release · doi:10.1016/j.jconrel.2010.05.011 · Cited by 386
Formulation aspects of biodegradable polymeric microspheres for antigen delivery
TAMBER, H., JOHANSEN, P., MERKLE, H., & GANDER, B. (2005) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2004.09.002 · Cited by 316
Self-citation
Metadata
- Authors
- Freitas, S., Walz, A., Merkle, H. P., & Gander, B.
- Venue
- Journal of Microencapsulation
- Publisher
- Informa UK Limited
- Published
- 2003-01-01
- Volume
- 20
- Issue
- 1
- Pages
- 67-85
- ISSN
- 0265-2048 (ISSN-L)
- 1464-5246
- OpenAlex
- W2040247032
- Cited by
- 57
- References
- 1
- FWCI
- 5.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Solvent extraction employing a static micromixer: a simple, robust and versatile technology for the microencapsulation of proteins. https://app.cochat.ai/papers/10.1080/02652040210162577
- The paper
- Freitas, S., Walz, A., Merkle, H. P., & Gander, B. (2003). Solvent extraction employing a static micromixer: a simple, robust and versatile technology for the microencapsulation of proteins. Journal of Microencapsulation. https://doi.org/10.1080/02652040210162577
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.